gsd-2019-11994
Vulnerability from gsd
Modified
2023-12-13 01:24
Details
A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=mmr_sf-EN_US000061901&withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2019-11994", "description": "A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=mmr_sf-EN_US000061901\u0026withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience.", "id": "GSD-2019-11994" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-11994" ], "details": "A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=mmr_sf-EN_US000061901\u0026withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience.", "id": "GSD-2019-11994", "modified": "2023-12-13T01:24:01.811750Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "security-alert@hpe.com", "ID": "CVE-2019-11994", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "HPE SimpliVity 2600 Gen10; HPE SimpliVity 380 Gen10; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 380 Gen9; SimpliVity OmniCube; SimpliVity OmniStack for Cisco; SimpliVity OmniStack for Dell; SimpliVity OmniStack for Lenovo", "version": { "version_data": [ { "version_value": "releases from 3.5.2 to 3.7.9" }, { "version_value": "releases from 3.6.2 to 3.7.9" }, { "version_value": "releases from 3.7.1 to 3.7.9" }, { "version_value": "releases from 3.7.8 to 3.7.9" }, { "version_value": "releases from 3.5.2 to 3.7.9" }, { "version_value": "releases from 3.5.2 to 3.7.9" }, { "version_value": "releases from 3.5.2 to 3.7.9" }, { "version_value": "releases from 3.7.5 to 3.7.9" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=mmr_sf-EN_US000061901\u0026withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "remote arbitrary command execution; remote arbitrary command execution" } ] } ] }, "references": { "reference_data": [ { "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03956en_us", "refsource": "MISC", "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03956en_us" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:hp:simplivity_380_gen9_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.7.9", "versionStartIncluding": "3.6.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:hp:simplivity_380_gen10_g_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.7.9", "versionStartIncluding": "3.7.8", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:hp:simplivity_380_gen10_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.7.9", "versionStartIncluding": "3.7.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:hp:simplivity_2600_gen10_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.7.9", "versionStartIncluding": "3.7.5", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:hp:simplivity_2600_gen10:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:hp:simplivity_omnicube_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.7.9", "versionStartIncluding": "3.5.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:hp:simplivity_omnicube:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:hp:simplivity_omnistack_for_dell_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.7.9", "versionStartIncluding": "3.5.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:hp:simplivity_omnistack_for_dell:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:hp:simplivity_omnistack_for_cisco_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.7.9", "versionStartIncluding": "3.5.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:hp:simplivity_omnistack_for_cisco:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:hp:simplivity_omnistack_for_lenovo_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.7.9", "versionStartIncluding": "3.5.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:hp:simplivity_omnistack_for_lenovo:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "security-alert@hpe.com", "ID": "CVE-2019-11994" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=mmr_sf-EN_US000061901\u0026withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-22" } ] } ] }, "references": { "reference_data": [ { "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03956en_us", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03956en_us" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2020-01-17T21:17Z", "publishedDate": "2020-01-03T18:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.