gsd-2019-1931
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
Multiple vulnerabilities in the RSS dashboard in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected device. The vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface of the affected device. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2019-1931", "description": "Multiple vulnerabilities in the RSS dashboard in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected device. The vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface of the affected device. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.", "id": "GSD-2019-1931" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-1931" ], "details": "Multiple vulnerabilities in the RSS dashboard in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected device. The vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface of the affected device. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.", "id": "GSD-2019-1931", "modified": "2023-12-13T01:23:51.928454Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2019-07-03T16:00:00-0700", "ID": "CVE-2019-1931", "STATE": "PUBLIC", "TITLE": "Cisco Firepower Management Center RSS Cross-Site Scripting Vulnerabilities" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco Firepower Management Center ", "version": { "version_data": [ { "affected": "\u003c", "version_value": "6.2.3.14" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple vulnerabilities in the RSS dashboard in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected device. The vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface of the affected device. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information." } ] }, "exploit": [ { "lang": "eng", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerabilities that are described in this advisory. " } ], "impact": { "cvss": { "baseScore": "6.1", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N ", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79" } ] } ] }, "references": { "reference_data": [ { "name": "20190703 Cisco Firepower Management Center RSS Cross-Site Scripting Vulnerabilities", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190703-fmc-xss" } ] }, "source": { "advisory": "cisco-sa-20190703-fmc-xss", "defect": [ [ "CSCvo90805", "CSCvo92913" ] ], "discovery": "INTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:6.5.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:6.2.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:6.3.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:6.4.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "ID": "CVE-2019-1931" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Multiple vulnerabilities in the RSS dashboard in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected device. The vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface of the affected device. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-79" } ] } ] }, "references": { "reference_data": [ { "name": "20190703 Cisco Firepower Management Center RSS Cross-Site Scripting Vulnerabilities", "refsource": "CISCO", "tags": [ "Vendor Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190703-fmc-xss" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 2.7 } }, "lastModifiedDate": "2019-10-09T23:48Z", "publishedDate": "2019-07-06T02:15Z" } } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.