GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

GSD-2020-14479

Vulnerability from gsd - Updated: 2023-12-13 01:21
Details
Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2020-14479",
    "description": "Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server",
    "id": "GSD-2020-14479"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2020-14479"
      ],
      "details": "Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server",
      "id": "GSD-2020-14479",
      "modified": "2023-12-13T01:21:59.884168Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "DATE_PUBLIC": "2020-07-14T17:00:00.000Z",
        "ID": "CVE-2020-14479",
        "STATE": "PUBLIC",
        "TITLE": "ICSA-20-147-01 Inductive Automation Ignition (Update B)"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Ignition 7 Gateway",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "All",
                          "version_value": "7.9.14"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Ignition 8 Gateway",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "All",
                          "version_value": "8.0.10"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Inductive Automation"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "Pedro Ribeiro, Radek Domanski, Chris Anastasio (muffin), and Steven Seeley (mr_me) working with Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-306 Missing Authentication for Critical Function"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01",
            "refsource": "MISC",
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01"
          }
        ]
      },
      "source": {
        "advisory": "ICSA-20-147-01",
        "discovery": "EXTERNAL"
      },
      "work_around": [
        {
          "lang": "eng",
          "value": "Please note CVE-2020-14479 does not have a fix in place. Induction Automation plans to correct this vulnerability in future product versions.\nIt is recommended to restrict interaction with the service to trusted machines. Only clients and servers with a legitimate procedural relationship should be permitted to communicate with the service. This can be done in various ways, most notably with firewall rules/allow listing.\nFor more information regarding software and patches, please refer to the specified version in Inductive Automation\u2019s release notes."
        }
      ]
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "7.9.14",
                "versionStartIncluding": "7.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "8.0.10",
                "versionStartIncluding": "8.0.1",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-14479"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01",
              "refsource": "MISC",
              "tags": [
                "Patch",
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 1.4
        }
      },
      "lastModifiedDate": "2022-04-09T00:38Z",
      "publishedDate": "2022-04-01T23:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…