GSD-2021-23281
Vulnerability from gsd - Updated: 2023-12-13 01:23Details
Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2021-23281",
"description": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code.",
"id": "GSD-2021-23281"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-23281"
],
"details": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code.",
"id": "GSD-2021-23281",
"modified": "2023-12-13T01:23:29.870207Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"AKA": "Code Injection",
"ASSIGNER": "CybersecurityCOE@eaton.com",
"DATE_PUBLIC": "2021-04-01T07:00:00.000Z",
"ID": "CVE-2021-23281",
"STATE": "PUBLIC",
"TITLE": "Remote Code execution"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intelligent Power manager (IPM)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.69"
}
]
}
}
]
},
"vendor_name": "Eaton"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Amir Preminger from Claroty research "
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf",
"refsource": "MISC",
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
]
},
"solution": [
{
"lang": "eng",
"value": "upgrade the software to latest version 1.69"
}
],
"source": {
"advisory": "ETN-VA-2021-1000",
"defect": [
"ETN-VA-2021-1000"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "eng",
"value": "To prevent the exploitation of the issues and safeguard the software from malicious entities, Eaton recommends blocking ports 4679 \u0026 4680 at the enterprise network or home network where Intelligent Power Manager (IPM) software is installed and used"
}
]
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:eaton:intelligent_power_manager:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.69",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "CybersecurityCOE@eaton.com",
"ID": "CVE-2021-23281"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0
}
},
"lastModifiedDate": "2021-04-20T17:55Z",
"publishedDate": "2021-04-13T19:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…