Details
Client-side JavaScript controls may be bypassed by directly running a JS function to reboot the PLC (e.g., from the browser console) or by loading the corresponding, browser accessible PHP script
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2022-1667",
    "description": "Client-side JavaScript controls may be bypassed by directly running a JS function to reboot the PLC (e.g., from the browser console) or by loading the corresponding, browser accessible PHP script",
    "id": "GSD-2022-1667"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2022-1667"
      ],
      "details": "Client-side JavaScript controls may be bypassed by directly running a JS function to reboot the PLC (e.g., from the browser console) or by loading the corresponding, browser accessible PHP script",
      "id": "GSD-2022-1667",
      "modified": "2023-12-13T01:19:27.802366Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "DATE_PUBLIC": "2022-06-23T17:01:00.000Z",
        "ID": "CVE-2022-1667",
        "STATE": "PUBLIC",
        "TITLE": "Secheron SEPCOS Control and Protection Relay"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "SEPCOS Control and Protection Relay firmware package",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "All versions",
                          "version_value": "1.23.21"
                        },
                        {
                          "version_affected": "\u003c",
                          "version_name": "All versions",
                          "version_value": "1.24.8"
                        },
                        {
                          "version_affected": "\u003c",
                          "version_name": "All versions",
                          "version_value": "1.25.3"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Secheron"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "Anthony Candarini of AECOM, Clark Bradley of Elliott Davis, Mike Curnow of AECOM, and Balakrishna Subramoney of SAM Analytic Solutions reported these vulnerabilities to CISA."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Client-side JavaScript controls may be bypassed by directly running a JS function to reboot the PLC (e.g., from the browser console) or by loading the corresponding, browser accessible PHP script"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-841  IMPROPER ENFORCEMENT OF BEHAVIORAL WORKFLOW"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-03",
            "refsource": "MISC",
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-03"
          }
        ]
      },
      "solution": [
        {
          "lang": "eng",
          "value": "Secheron recommends updating its software to the latest version:\n\nSEPCOS Single Package firmware (1.23.xx feature level): Update to 1.23.22 or higher version\nSEPCOS Single Package firmware (1.24.xx feature level): Update to 1.24.8 or higher version\nSEPCOS Single Package firmware (1.25.xx feature level): Update to 1.25.3 or higher version"
        }
      ],
      "source": {
        "advisory": "ICSA-22-174-03",
        "discovery": "EXTERNAL"
      },
      "work_around": [
        {
          "lang": "eng",
          "value": "Additional workarounds are suggested to help reduce the risk:\n\nConfigure the network such that PLC communications are strictly limited to only the devices required to perform its functions.\nLimit remote access and close Ports 80 and 443 at the switch level.\nOnly use approved devices to connect to the PLCs. Do not connect personal peripherals (USB sticks, hotspots) to approved devices.\nCheck device logs during periodic maintenance for unauthorized changes or access."
        }
      ]
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:secheron:sepcos_control_and_protection_relay_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.25.3",
                    "versionStartIncluding": "1.25.0",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:secheron:sepcos_control_and_protection_relay_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.24.8",
                    "versionStartIncluding": "1.24.0",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:secheron:sepcos_control_and_protection_relay_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.23.21",
                    "versionStartIncluding": "1.23.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:secheron:sepcos_control_and_protection_relay:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2022-1667"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Client-side JavaScript controls may be bypassed by directly running a JS function to reboot the PLC (e.g., from the browser console) or by loading the corresponding, browser accessible PHP script"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "NVD-CWE-Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-03",
              "refsource": "MISC",
              "tags": [
                "Mitigation",
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-03"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 6.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2022-07-05T15:54Z",
      "publishedDate": "2022-06-24T15:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…