GSD-2022-29898

Vulnerability from gsd - Updated: 2023-12-13 01:19
Details
On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2022-29898",
    "description": "On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.",
    "id": "GSD-2022-29898"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2022-29898"
      ],
      "details": "On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.",
      "id": "GSD-2022-29898",
      "modified": "2023-12-13T01:19:41.716271Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "info@cert.vde.com",
        "DATE_PUBLIC": "2022-05-11T13:00:00.000Z",
        "ID": "CVE-2022-29898",
        "STATE": "PUBLIC",
        "TITLE": "Remote Code Execution in all versions of various RAD-ISM-900-EN-* devices by PHOENIX CONTACT"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "RAD-ISM-900-EN-BD/B",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_name": "All Versions",
                          "version_value": "All Versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "RAD-ISM-900-EN-BD",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_name": "All Versions",
                          "version_value": "All Versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "RAD-ISM-900-EN-BD-BUS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_name": "All Versions",
                          "version_value": "All Versions"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "PHOENIX CONTACT"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "The vulnerabilities were discovered and reported by Logan Carpenter of DRAGOS."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": " CWE-354 Improper Validation of Integrity Check Value"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert.vde.com/en/advisories/VDE-2022-018/",
            "refsource": "CONFIRM",
            "url": "https://cert.vde.com/en/advisories/VDE-2022-018/"
          }
        ]
      },
      "source": {
        "advisory": "VDE-2022-018",
        "discovery": "EXTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:phoenixcontact:rad-ism-900-en-bd_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:phoenixcontact:rad-ism-900-en-bd:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:phoenixcontact:rad-ism-900-en-bd\\/b_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:phoenixcontact:rad-ism-900-en-bd\\/b:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:phoenixcontact:rad-ism-900-en-bd-bus_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:phoenixcontact:rad-ism-900-en-bd-bus:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "ID": "CVE-2022-29898"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-354"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-018/",
              "refsource": "CONFIRM",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-018/"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.3,
          "impactScore": 6.0
        }
      },
      "lastModifiedDate": "2022-05-20T14:16Z",
      "publishedDate": "2022-05-11T15:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…