GSD-2022-31694

Vulnerability from gsd - Updated: 2023-12-13 01:19
Details
InstallBuilder Qt installers built with versions previous to 22.10 try to load DLLs from the installer binary parent directory when displaying popups. This may allow an attacker to plant a malicious DLL in the installer parent directory to allow executing code with the privileges of the installer (when the popup triggers the loading of the library). Exploiting these type of vulnerabilities generally require that an attacker has access to a vulnerable machine to plant the malicious DLL.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2022-31694",
    "description": "InstallBuilder Qt installers built with versions previous to 22.10 try to load DLLs from the installer binary parent directory when displaying popups. This may allow an attacker to plant a malicious DLL in the installer parent directory to allow executing code with the privileges of the installer (when the popup triggers the loading of the library). Exploiting these type of vulnerabilities generally require that an attacker has access to a vulnerable machine to plant the malicious DLL.",
    "id": "GSD-2022-31694"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2022-31694"
      ],
      "details": "InstallBuilder Qt installers built with versions previous to 22.10 try to load DLLs from the installer binary parent directory when displaying popups. This may allow an attacker to plant a malicious DLL in the installer parent directory to allow executing code with the privileges of the installer (when the popup triggers the loading of the library). Exploiting these type of vulnerabilities generally require that an attacker has access to a vulnerable machine to plant the malicious DLL.",
      "id": "GSD-2022-31694",
      "modified": "2023-12-13T01:19:17.927432Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "security@vmware.com",
        "ID": "CVE-2022-31694",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "VMware InstallBuilder",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All InstallBuilder for Qt versions prior to version 22.10.0"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "InstallBuilder Qt installers built with versions previous to 22.10 try to load DLLs from the installer binary parent directory when displaying popups. This may allow an attacker to plant a malicious DLL in the installer parent directory to allow executing code with the privileges of the installer (when the popup triggers the loading of the library). Exploiting these type of vulnerabilities generally require that an attacker has access to a vulnerable machine to plant the malicious DLL."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "Uncontrolled Search Path Element"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://blog.installbuilder.com/2022/11/installbuilder-22100-released.html",
            "refsource": "MISC",
            "url": "https://blog.installbuilder.com/2022/11/installbuilder-22100-released.html"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:installbuilder:installbuilder:*:*:*:*:*:qt:*:*",
                "cpe_name": [],
                "versionEndExcluding": "22.10.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "security@vmware.com",
          "ID": "CVE-2022-31694"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "InstallBuilder Qt installers built with versions previous to 22.10 try to load DLLs from the installer binary parent directory when displaying popups. This may allow an attacker to plant a malicious DLL in the installer parent directory to allow executing code with the privileges of the installer (when the popup triggers the loading of the library). Exploiting these type of vulnerabilities generally require that an attacker has access to a vulnerable machine to plant the malicious DLL."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-427"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.installbuilder.com/2022/11/installbuilder-22100-released.html",
              "refsource": "MISC",
              "tags": [
                "Release Notes",
                "Vendor Advisory"
              ],
              "url": "https://blog.installbuilder.com/2022/11/installbuilder-22100-released.html"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 1.3,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2022-11-22T20:31Z",
      "publishedDate": "2022-11-18T23:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…