GSD-2022-3369

Vulnerability from gsd - Updated: 2023-12-13 01:19
Details
An Improper Access Control vulnerability in the bdservicehost.exe component, as used in Bitdefender Engines for Windows, allows an attacker to delete privileged registry keys by pointing a Registry symlink to a privileged key. This issue affects: Bitdefender Engines versions prior to 7.92659. It also affects Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as well as Bitdefender Endpoint Security Tools for Windows with engine versions prior to 7.92659.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2022-3369",
    "id": "GSD-2022-3369"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2022-3369"
      ],
      "details": "An Improper Access Control vulnerability in the bdservicehost.exe component, as used in Bitdefender Engines for Windows, allows an attacker to delete privileged registry keys by pointing a Registry symlink to a privileged key. This issue affects: Bitdefender Engines versions prior to 7.92659. It also affects Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as well as Bitdefender Endpoint Security Tools for Windows with engine versions prior to 7.92659.",
      "id": "GSD-2022-3369",
      "modified": "2023-12-13T01:19:39.970034Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cve-requests@bitdefender.com",
        "ID": "CVE-2022-3369",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Engines",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "unspecified"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Bitdefender"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "An Improper Access Control vulnerability in the bdservicehost.exe component, as used in Bitdefender Engines for Windows, allows an attacker to delete privileged registry keys by pointing a Registry symlink to a privileged key. This issue affects: Bitdefender Engines versions prior to 7.92659. It also affects Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as well as Bitdefender Endpoint Security Tools for Windows with engine versions prior to 7.92659."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-269",
                "lang": "eng",
                "value": "CWE-269 Improper Privilege Management"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.bitdefender.com/support/security-advisories/improper-handling-of-registry-symbolic-links-in-bitdefender-engines-va-10562",
            "refsource": "MISC",
            "url": "https://www.bitdefender.com/support/security-advisories/improper-handling-of-registry-symbolic-links-in-bitdefender-engines-va-10562"
          }
        ]
      },
      "solution": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn automatic update to Engines version 7.92659 fixes the issue.\u003c/p\u003e"
            }
          ],
          "value": "An automatic update to Engines version 7.92659 fixes the issue.\n\n"
        }
      ],
      "source": {
        "defect": [
          "VA-10562"
        ],
        "discovery": "EXTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:bitdefender:engines:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "7.92659",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cve-requests@bitdefender.com",
          "ID": "CVE-2022-3369"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "An Improper Access Control vulnerability in the bdservicehost.exe component, as used in Bitdefender Engines for Windows, allows an attacker to delete privileged registry keys by pointing a Registry symlink to a privileged key. This issue affects: Bitdefender Engines versions prior to 7.92659. It also affects Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as well as Bitdefender Endpoint Security Tools for Windows with engine versions prior to 7.92659."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-269"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.bitdefender.com/support/security-advisories/improper-handling-of-registry-symbolic-links-in-bitdefender-engines-va-10562",
              "refsource": "MISC",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://www.bitdefender.com/support/security-advisories/improper-handling-of-registry-symbolic-links-in-bitdefender-engines-va-10562"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 1.8,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2023-02-16T02:56Z",
      "publishedDate": "2022-11-01T08:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…