GSD-2022-43769

Vulnerability from gsd - Updated: 2023-12-13 01:19
Details
Hitachi Vantara Pentaho Business Analytics Server prior to versions 9.4.0.1 and 9.3.0.2, including 8.3.x allow certain web services to set property values which contain Spring templates that are interpreted downstream. 
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2022-43769",
    "id": "GSD-2022-43769"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2022-43769"
      ],
      "details": "\nHitachi Vantara Pentaho Business Analytics Server prior to versions 9.4.0.1 and 9.3.0.2, including 8.3.x allow certain web services to set property values which contain Spring templates that are interpreted downstream.\u00a0\n\n",
      "id": "GSD-2022-43769",
      "modified": "2023-12-13T01:19:31.588808Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "security.vulnerabilities@hitachivantara.com",
        "ID": "CVE-2022-43769",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Pentaho Business Analytics Server",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "1.0",
                          "version_value": "9.3.0.2"
                        },
                        {
                          "version_affected": "\u003c",
                          "version_name": "9.4.0.0",
                          "version_value": "9.4.0.1"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Hitachi Vantara"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "Harry Withington, Aura Information Security"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "\nHitachi Vantara Pentaho Business Analytics Server prior to versions 9.4.0.1 and 9.3.0.2, including 8.3.x allow certain web services to set property values which contain Spring templates that are interpreted downstream.\u00a0\n\n"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-74",
                "lang": "eng",
                "value": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://support.pentaho.com/hc/en-us/articles/14455561548301--Resolved-Pentaho-BA-Server-Failure-to-Sanitize-Special-Elements-into-a-Different-Plane-Special-Element-Injection-Versions-before-9-4-0-1-and-9-3-0-2-including-8-3-x-Impacted-CVE-2022-43769-",
            "refsource": "MISC",
            "url": "https://support.pentaho.com/hc/en-us/articles/14455561548301--Resolved-Pentaho-BA-Server-Failure-to-Sanitize-Special-Elements-into-a-Different-Plane-Special-Element-Injection-Versions-before-9-4-0-1-and-9-3-0-2-including-8-3-x-Impacted-CVE-2022-43769-"
          },
          {
            "name": "http://packetstormsecurity.com/files/172296/Pentaho-Business-Server-Authentication-Bypass-SSTI-Code-Execution.html",
            "refsource": "MISC",
            "url": "http://packetstormsecurity.com/files/172296/Pentaho-Business-Server-Authentication-Bypass-SSTI-Code-Execution.html"
          }
        ]
      },
      "source": {
        "discovery": "EXTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:hitachi:vantara_pentaho_business_analytics_server:9.4.0.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:hitachi:vantara_pentaho_business_analytics_server:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "9.3.0.2",
                "versionStartIncluding": "8.3.0.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "security.vulnerabilities@hitachivantara.com",
          "ID": "CVE-2022-43769"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "\nHitachi Vantara Pentaho Business Analytics Server prior to versions 9.4.0.1 and 9.3.0.2, including 8.3.x allow certain web services to set property values which contain Spring templates that are interpreted downstream.\u00a0\n\n"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-94"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.pentaho.com/hc/en-us/articles/14455561548301--Resolved-Pentaho-BA-Server-Failure-to-Sanitize-Special-Elements-into-a-Different-Plane-Special-Element-Injection-Versions-before-9-4-0-1-and-9-3-0-2-including-8-3-x-Impacted-CVE-2022-43769-",
              "refsource": "MISC",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://support.pentaho.com/hc/en-us/articles/14455561548301--Resolved-Pentaho-BA-Server-Failure-to-Sanitize-Special-Elements-into-a-Different-Plane-Special-Element-Injection-Versions-before-9-4-0-1-and-9-3-0-2-including-8-3-x-Impacted-CVE-2022-43769-"
            },
            {
              "name": "http://packetstormsecurity.com/files/172296/Pentaho-Business-Server-Authentication-Bypass-SSTI-Code-Execution.html",
              "refsource": "MISC",
              "tags": [],
              "url": "http://packetstormsecurity.com/files/172296/Pentaho-Business-Server-Authentication-Bypass-SSTI-Code-Execution.html"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 1.2,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2023-05-11T18:15Z",
      "publishedDate": "2023-04-03T18:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…