GSD-2023-20038
Vulnerability from gsd - Updated: 2023-12-13 01:20Details
A vulnerability in the monitoring application of Cisco Industrial Network Director could allow an authenticated, local attacker to access a static secret key used to store both local data and credentials for accessing remote systems. This vulnerability is due to a static key value stored in the application used to encrypt application data and remote credentials. An attacker could exploit this vulnerability by gaining local access to the server Cisco Industrial Network Director is installed on. A successful exploit could allow the attacker to decrypt data allowing the attacker to access remote systems monitored by Cisco Industrial Network Director.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-20038",
"id": "GSD-2023-20038"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-20038"
],
"details": "A vulnerability in the monitoring application of Cisco Industrial Network Director could allow an authenticated, local attacker to access a static secret key used to store both local data and credentials for accessing remote systems. This vulnerability is due to a static key value stored in the application used to encrypt application data and remote credentials. An attacker could exploit this vulnerability by gaining local access to the server Cisco Industrial Network Director is installed on. A successful exploit could allow the attacker to decrypt data allowing the attacker to access remote systems monitored by Cisco Industrial Network Director.",
"id": "GSD-2023-20038",
"modified": "2023-12-13T01:20:28.394287Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2023-20038",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco Industrial Network Director",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "1.5.0"
},
{
"version_affected": "=",
"version_value": "1.5.1"
},
{
"version_affected": "=",
"version_value": "1.4.0"
},
{
"version_affected": "=",
"version_value": "1.0.0"
},
{
"version_affected": "=",
"version_value": "1.0.1"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the monitoring application of Cisco Industrial Network Director could allow an authenticated, local attacker to access a static secret key used to store both local data and credentials for accessing remote systems.\r\n\r This vulnerability is due to a static key value stored in the application used to encrypt application data and remote credentials. An attacker could exploit this vulnerability by gaining local access to the server Cisco Industrial Network Director is installed on. A successful exploit could allow the attacker to decrypt data allowing the attacker to access remote systems monitored by Cisco Industrial Network Director."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerabilities that are described in this advisory."
}
],
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-321",
"lang": "eng",
"value": "Use of Hard-coded Cryptographic Key"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ind-fZyVjJtG",
"refsource": "MISC",
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ind-fZyVjJtG"
}
]
},
"source": {
"advisory": "cisco-sa-ind-fZyVjJtG",
"defects": [
"CSCwc29341"
],
"discovery": "EXTERNAL"
}
},
"nvd.nist.gov": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:cisco:industrial_network_director:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EA14F071-EA44-4A75-B5F0-2C82E68C972F",
"versionEndExcluding": "1.6.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the monitoring application of Cisco Industrial Network Director could allow an authenticated, local attacker to access a static secret key used to store both local data and credentials for accessing remote systems.\r\n\r This vulnerability is due to a static key value stored in the application used to encrypt application data and remote credentials. An attacker could exploit this vulnerability by gaining local access to the server Cisco Industrial Network Director is installed on. A successful exploit could allow the attacker to decrypt data allowing the attacker to access remote systems monitored by Cisco Industrial Network Director."
}
],
"id": "CVE-2023-20038",
"lastModified": "2024-01-25T17:15:26.670",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.0,
"impactScore": 6.0,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.0,
"impactScore": 6.0,
"source": "ykramarz@cisco.com",
"type": "Secondary"
}
]
},
"published": "2023-01-20T07:15:15.493",
"references": [
{
"source": "ykramarz@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ind-fZyVjJtG"
}
],
"sourceIdentifier": "ykramarz@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-321"
}
],
"source": "ykramarz@cisco.com",
"type": "Secondary"
}
]
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…