A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that
could cause denial of service of the controller when communicating over the Modbus TCP
protocol.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-25619", "id": "GSD-2023-25619" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-25619" ], "details": "\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n", "id": "GSD-2023-25619", "modified": "2023-12-13T01:20:39.900275Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2023-25619", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Modicon M340 CPU (part numbers BMXP34*) ", "version": { "version_data": [ { "version_affected": "=", "version_value": "prior to SV3.51" } ] } }, { "product_name": "Modicon M580 CPU (part numbers BMEP* and BMEH*)", "version": { "version_data": [ { "version_affected": "=", "version_value": "prior to V4.10" } ] } }, { "product_name": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All " } ] } }, { "product_name": "Modicon Momentum Unity M1E Processor (171CBU*)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All" } ] } }, { "product_name": "Modicon MC80 (BMKC80)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All" } ] } }, { "product_name": "Legacy Modicon Quantum (140CPU65*)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All" } ] } }, { "product_name": "Legacy Modicon Premium CPUs (TSXP57*)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-754", "lang": "eng", "value": "CWE-754 Improper Check for Unusual or Exceptional Conditions" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf" } ] }, "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.51", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_momentum_unity_m1e_processor_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_momentum_unity_m1e_processor:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_mc80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_mc80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp57_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp57:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:bmep58s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:bmep58s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:bmeh58s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:bmeh58s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2023-25619" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-754" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf", "refsource": "MISC", "tags": [], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2023-05-12T05:15Z", "publishedDate": "2023-04-19T08:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.