gsd-2023-28489
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter “Remote Operation” is enabled. The parameter is disabled by default.
The vulnerability could allow an unauthenticated remote attacker to perform arbitrary code execution on the device.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-28489", "id": "GSD-2023-28489" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-28489" ], "details": "A vulnerability has been identified in CP-8031 MASTER MODULE (All versions \u003c CPCI85 V05), CP-8050 MASTER MODULE (All versions \u003c CPCI85 V05). Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter \u201cRemote Operation\u201d is enabled. The parameter is disabled by default.\r\nThe vulnerability could allow an unauthenticated remote attacker to perform arbitrary code execution on the device.", "id": "GSD-2023-28489", "modified": "2023-12-13T01:20:48.940682Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-28489", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CP-8031 MASTER MODULE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c CPCI85 V05" } ] } }, { "product_name": "CP-8050 MASTER MODULE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c CPCI85 V05" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in CP-8031 MASTER MODULE (All versions \u003c CPCI85 V05), CP-8050 MASTER MODULE (All versions \u003c CPCI85 V05). Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter \u201cRemote Operation\u201d is enabled. The parameter is disabled by default.\r\nThe vulnerability could allow an unauthenticated remote attacker to perform arbitrary code execution on the device." } ] }, "impact": { "cvss": [ { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-77", "lang": "eng", "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-472454.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-472454.pdf" }, { "name": "http://seclists.org/fulldisclosure/2023/Jul/14", "refsource": "MISC", "url": "http://seclists.org/fulldisclosure/2023/Jul/14" }, { "name": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html", "refsource": "MISC", "url": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:cp-8031_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "cpci85_v05", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:cp-8031:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:cp-8050_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "cpci85_v05", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:cp-8050:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-28489" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in CP-8031 MASTER MODULE (All versions \u003c CPCI85 V05), CP-8050 MASTER MODULE (All versions \u003c CPCI85 V05). Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter \u201cRemote Operation\u201d is enabled. The parameter is disabled by default.\r\nThe vulnerability could allow an unauthenticated remote attacker to perform arbitrary code execution on the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-77" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-472454.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-472454.pdf" }, { "name": "http://seclists.org/fulldisclosure/2023/Jul/14", "refsource": "MISC", "tags": [], "url": "http://seclists.org/fulldisclosure/2023/Jul/14" }, { "name": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html", "refsource": "MISC", "tags": [], "url": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2023-07-11T18:15Z", "publishedDate": "2023-04-11T10:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.