GSD-2023-29464
Vulnerability from gsd - Updated: 2023-12-13 01:20Details
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-29464",
"id": "GSD-2023-29464"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-29464"
],
"details": "\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\n\n",
"id": "GSD-2023-29464",
"modified": "2023-12-13T01:20:56.728848Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT@rockwellautomation.com",
"ID": "CVE-2023-29464",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "FactoryTalk Linx ",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "6.20"
},
{
"version_affected": "=",
"version_value": "6.30"
}
]
}
}
]
},
"vendor_name": "Rockwell Automation"
}
]
}
},
"credits": [
{
"lang": "en",
"value": "Rockwell Automation would like to thank Yuval Gordon, CPS Research, Microsoft Threat Intelligence Community for reporting this vulnerability to us."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\n\n"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-20",
"lang": "eng",
"value": "CWE-20 Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040",
"refsource": "MISC",
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040"
}
]
},
"solution": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003eInstall the security patches for the respective versions, referencing \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402\"\u003eBF29637 - Patch: Hardening of the FactoryTalk Linx communications service for MobileView to authenticate and block improperly sized files, FactoryTalk Linx 6.20, 6.30\u003c/a\u003e.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "\n * Install the security patches for the respective versions, referencing BF29637 - Patch: Hardening of the FactoryTalk Linx communications service for MobileView to authenticate and block improperly sized files, FactoryTalk Linx 6.20, 6.30 https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402 .\n\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT@rockwellautomation.com",
"ID": "CVE-2023-29464"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040",
"refsource": "MISC",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2
}
},
"lastModifiedDate": "2023-10-20T20:10Z",
"publishedDate": "2023-10-13T13:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…