CVE-2023-29464 (GCVE-0-2023-29464)

Vulnerability from cvelistv5 – Published: 2023-10-13 12:57 – Updated: 2024-09-17 16:58
VLAI?
Summary
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
CWE
  • CWE-20 - Improper Input Validation
Assigner
Impacted products
Vendor Product Version
Rockwell Automation FactoryTalk Linx Affected: 6.20
Affected: 6.30
Create a notification for this product.
Credits
Rockwell Automation would like to thank Yuval Gordon, CPS Research, Microsoft Threat Intelligence Community for reporting this vulnerability to us.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:07:46.248Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "factorytalk_linx",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "6.20"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "factorytalk_linx",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "6.30"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-29464",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-17T16:57:57.383746Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-17T16:58:55.796Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk Linx ",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "6.20"
            },
            {
              "status": "affected",
              "version": "6.30"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Rockwell Automation would like to thank Yuval Gordon, CPS Research, Microsoft Threat Intelligence Community for reporting this vulnerability to us."
        }
      ],
      "datePublic": "2023-10-12T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-10",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-10 Buffer Overflow via Environment Variables"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-13T12:57:25.490Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cul\u003e\u003cli\u003eInstall the security patches for the respective versions, referencing \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402\"\u003eBF29637 - Patch: Hardening of the FactoryTalk Linx communications service for MobileView to authenticate and block improperly sized files, FactoryTalk Linx 6.20, 6.30\u003c/a\u003e.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\n  *  Install the security patches for the respective versions, referencing  BF29637 - Patch: Hardening of the FactoryTalk Linx communications service for MobileView to authenticate and block improperly sized files, FactoryTalk Linx 6.20, 6.30 https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402 .\n\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rockwell Automation FactoryTalk Linx Vulnerable to Denial-of-Service and Information Disclosure",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2023-29464",
    "datePublished": "2023-10-13T12:57:25.490Z",
    "dateReserved": "2023-04-06T18:42:59.008Z",
    "dateUpdated": "2024-09-17T16:58:55.796Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D0753AB1-A633-4B8B-983E-1FA04EDDB2BD\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"22A83428-A3F4-45DD-95D2-D938CE82E4AE\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"\\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\\n\\n\"}, {\"lang\": \"es\", \"value\": \"FactoryTalk Linx, en Rockwell Automation PanelView Plus, permite que un actor de amenazas no autenticado lea datos de la memoria a trav\\u00e9s de paquetes maliciosos manipulados. Enviar un tama\\u00f1o mayor que el tama\\u00f1o del b\\u00fafer da como resultado una fuga de datos de la memoria, lo que resulta en una divulgaci\\u00f3n de informaci\\u00f3n. Si el tama\\u00f1o es lo suficientemente grande, hace que las comunicaciones a trav\\u00e9s del protocolo industrial com\\u00fan dejen de responder a cualquier tipo de paquete, lo que resulta en una Denegaci\\u00f3n de Servicio (DoS) para FactoryTalk Linx a trav\\u00e9s del protocolo industrial com\\u00fan.\"}]",
      "id": "CVE-2023-29464",
      "lastModified": "2024-11-21T07:57:07.377",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H\", \"baseScore\": 8.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 4.2}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\", \"baseScore\": 9.1, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.2}]}",
      "published": "2023-10-13T13:15:11.453",
      "references": "[{\"url\": \"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040\", \"source\": \"PSIRT@rockwellautomation.com\", \"tags\": [\"Permissions Required\", \"Vendor Advisory\"]}, {\"url\": \"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Permissions Required\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "PSIRT@rockwellautomation.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-20\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-29464\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2023-10-13T13:15:11.453\",\"lastModified\":\"2024-11-21T07:57:07.377\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\\n\\n\"},{\"lang\":\"es\",\"value\":\"FactoryTalk Linx, en Rockwell Automation PanelView Plus, permite que un actor de amenazas no autenticado lea datos de la memoria a trav\u00e9s de paquetes maliciosos manipulados. Enviar un tama\u00f1o mayor que el tama\u00f1o del b\u00fafer da como resultado una fuga de datos de la memoria, lo que resulta en una divulgaci\u00f3n de informaci\u00f3n. Si el tama\u00f1o es lo suficientemente grande, hace que las comunicaciones a trav\u00e9s del protocolo industrial com\u00fan dejen de responder a cualquier tipo de paquete, lo que resulta en una Denegaci\u00f3n de Servicio (DoS) para FactoryTalk Linx a trav\u00e9s del protocolo industrial com\u00fan.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":4.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D0753AB1-A633-4B8B-983E-1FA04EDDB2BD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"22A83428-A3F4-45DD-95D2-D938CE82E4AE\"}]}]}],\"references\":[{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Permissions Required\",\"Vendor Advisory\"]},{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T14:07:46.248Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-29464\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-17T16:57:57.383746Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"factorytalk_linx\", \"versions\": [{\"status\": \"affected\", \"version\": \"6.20\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"factorytalk_linx\", \"versions\": [{\"status\": \"affected\", \"version\": \"6.30\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-17T16:58:51.788Z\"}}], \"cna\": {\"title\": \"Rockwell Automation FactoryTalk Linx Vulnerable to Denial-of-Service and Information Disclosure\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Rockwell Automation would like to thank Yuval Gordon, CPS Research, Microsoft Threat Intelligence Community for reporting this vulnerability to us.\"}], \"impacts\": [{\"capecId\": \"CAPEC-10\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-10 Buffer Overflow via Environment Variables\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Rockwell Automation\", \"product\": \"FactoryTalk Linx \", \"versions\": [{\"status\": \"affected\", \"version\": \"6.20\"}, {\"status\": \"affected\", \"version\": \"6.30\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"\\n  *  Install the security patches for the respective versions, referencing  BF29637 - Patch: Hardening of the FactoryTalk Linx communications service for MobileView to authenticate and block improperly sized files, FactoryTalk Linx 6.20, 6.30 https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402 .\\n\\n\\n\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cul\u003e\u003cli\u003eInstall the security patches for the respective versions, referencing \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402\\\"\u003eBF29637 - Patch: Hardening of the FactoryTalk Linx communications service for MobileView to authenticate and block improperly sized files, FactoryTalk Linx 6.20, 6.30\u003c/a\u003e.\u003c/li\u003e\u003c/ul\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"datePublic\": \"2023-10-12T14:00:00.000Z\", \"references\": [{\"url\": \"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20 Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2023-10-13T12:57:25.490Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-29464\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-17T16:58:55.796Z\", \"dateReserved\": \"2023-04-06T18:42:59.008Z\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"datePublished\": \"2023-10-13T12:57:25.490Z\", \"assignerShortName\": \"Rockwell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…