gsd-2023-3001
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2023-3001",
    "id": "GSD-2023-3001"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-3001"
      ],
      "details": "\nA CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that\ncould cause an interpretation of malicious payload data, potentially leading to remote code\nexecution when an attacker gets the user to open a malicious file. \n\n",
      "id": "GSD-2023-3001",
      "modified": "2023-12-13T01:20:54.387190Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cybersecurity@schneider-electric.com",
        "ID": "CVE-2023-3001",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "IGSS Dashboard (DashBoard.exe)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "v16.0.0.23130 and prior"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Schneider Electric"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "\nA CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that\ncould cause an interpretation of malicious payload data, potentially leading to remote code\nexecution when an attacker gets the user to open a malicious file. \n\n"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-502",
                "lang": "eng",
                "value": "CWE-502 Deserialization of Untrusted Data"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-02.pdf",
            "refsource": "MISC",
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-02.pdf"
          }
        ]
      },
      "source": {
        "discovery": "UNKNOWN"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "16.0.0.23131",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2023-3001"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "\nA CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that\ncould cause an interpretation of malicious payload data, potentially leading to remote code\nexecution when an attacker gets the user to open a malicious file. \n\n"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-502"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-02.pdf",
              "refsource": "MISC",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-02.pdf"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 1.8,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2023-06-21T21:06Z",
      "publishedDate": "2023-06-14T08:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.