gsd-2023-33919
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-33919", "id": "GSD-2023-33919" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-33919" ], "details": "A vulnerability has been identified in CP-8031 MASTER MODULE (All versions \u003c CPCI85 V05), CP-8050 MASTER MODULE (All versions \u003c CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.", "id": "GSD-2023-33919", "modified": "2023-12-13T01:20:36.565187Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-33919", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CP-8031 MASTER MODULE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c CPCI85 V05" } ] } }, { "product_name": "CP-8050 MASTER MODULE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c CPCI85 V05" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in CP-8031 MASTER MODULE (All versions \u003c CPCI85 V05), CP-8050 MASTER MODULE (All versions \u003c CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges." } ] }, "impact": { "cvss": [ { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-77", "lang": "eng", "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf" }, { "name": "http://seclists.org/fulldisclosure/2023/Jul/14", "refsource": "MISC", "url": "http://seclists.org/fulldisclosure/2023/Jul/14" }, { "name": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html", "refsource": "MISC", "url": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:cpci85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "v05", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:cp-8031_master_module:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:cpci85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "v05", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:cp-8050_master_module:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-33919" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in CP-8031 MASTER MODULE (All versions \u003c CPCI85 V05), CP-8050 MASTER MODULE (All versions \u003c CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-77" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf" }, { "name": "http://seclists.org/fulldisclosure/2023/Jul/14", "refsource": "MISC", "tags": [], "url": "http://seclists.org/fulldisclosure/2023/Jul/14" }, { "name": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html", "refsource": "MISC", "tags": [], "url": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9 } }, "lastModifiedDate": "2023-07-11T18:15Z", "publishedDate": "2023-06-13T09:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.