GSD-2023-34063
Vulnerability from gsd - Updated: 2023-12-13 01:20Details
Aria Automation contains a Missing Access Control vulnerability.
An authenticated malicious actor may
exploit this vulnerability leading to unauthorized access to remote
organizations and workflows.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-34063",
"id": "GSD-2023-34063"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-34063"
],
"details": "Aria Automation contains a Missing Access Control vulnerability.\n\n\nAn authenticated malicious actor may \nexploit this vulnerability leading to unauthorized access to remote \norganizations and workflows.\n\n",
"id": "GSD-2023-34063",
"modified": "2023-12-13T01:20:30.432659Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "security@vmware.com",
"ID": "CVE-2023-34063",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "VMware Aria Automation, VMware Cloud Foundation",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Aria Automation 8.14.1, Aria Automation 8.14.0, Aria Automation 8.13.1, Aria Automation 8.13.0, Aria Automation 8.12.2, Aria Automation 8.12.1, Aria Automation 8.12.0, Aria Automation 8.11.2, Aria Automation 8.11.1, Aria Automation 8.11.0 "
}
]
}
}
]
},
"vendor_name": "N/A"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Aria Automation contains a Missing Access Control vulnerability.\n\n\nAn authenticated malicious actor may \nexploit this vulnerability leading to unauthorized access to remote \norganizations and workflows.\n\n"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:H/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "VMware Aria Automation Missing Access Control Vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.vmware.com/security/advisories/VMSA-2024-0001.html",
"refsource": "MISC",
"url": "https://www.vmware.com/security/advisories/VMSA-2024-0001.html"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:vmware:aria_automation:8.11.0:*:*:*:*:*:*:*",
"matchCriteriaId": "183DC197-4FF2-4B84-B0E8-666E49CC9DDF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:aria_automation:8.11.1:*:*:*:*:*:*:*",
"matchCriteriaId": "2849AEA0-B419-4096-B1D8-796686CE4C56",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:aria_automation:8.11.2:*:*:*:*:*:*:*",
"matchCriteriaId": "CFFC657E-8780-46FE-AC01-22F8CFF196C9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:aria_automation:8.12.0:*:*:*:*:*:*:*",
"matchCriteriaId": "91E0F535-5F30-495E-9974-2C2F65ED94EE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:aria_automation:8.12.1:*:*:*:*:*:*:*",
"matchCriteriaId": "C8B7BAD1-8544-491E-B41F-B4CD4E2B3754",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:aria_automation:8.12.2:*:*:*:*:*:*:*",
"matchCriteriaId": "FF9CA281-ACE8-4768-A5EC-EB29111CD3EC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:aria_automation:8.13.0:*:*:*:*:*:*:*",
"matchCriteriaId": "AB173C24-3DDA-46CA-9B80-9A2C4EB73768",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:aria_automation:8.13.1:*:*:*:*:*:*:*",
"matchCriteriaId": "24986636-3F4B-46CF-A374-0D006216731F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:aria_automation:8.14.0:*:*:*:*:*:*:*",
"matchCriteriaId": "FB6E2175-E4C2-46A7-9D37-E37A8239B16D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:aria_automation:8.14.1:*:*:*:*:*:*:*",
"matchCriteriaId": "6F48CE31-68D2-4FE8-9BB2-ADC85259552A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:cloud_foundation:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "38EB0C0C-56CF-4A8F-A36F-E0E180B9059E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:vmware:cloud_foundation:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "D3D640F9-7733-415F-8BA7-DC41658EDC76",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Aria Automation contains a Missing Access Control vulnerability.\n\n\nAn authenticated malicious actor may \nexploit this vulnerability leading to unauthorized access to remote \norganizations and workflows.\n\n"
},
{
"lang": "es",
"value": "Aria Automation contiene una vulnerabilidad de control de acceso faltante. Un actor malicioso autenticado puede explotar esta vulnerabilidad y provocar acceso no autorizado a organizaciones y workflows remotos."
}
],
"id": "CVE-2023-34063",
"lastModified": "2024-01-25T16:22:30.063",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.5,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.1,
"impactScore": 6.0,
"source": "security@vmware.com",
"type": "Secondary"
}
]
},
"published": "2024-01-16T10:15:07.347",
"references": [
{
"source": "security@vmware.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.vmware.com/security/advisories/VMSA-2024-0001.html"
}
],
"sourceIdentifier": "security@vmware.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-862"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…