gsd-2023-34213
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
TN-5900 Series firmware versions v3.3 and prior are vulnerable to command-injection vulnerability. This vulnerability stems from insufficient input validation and improper authentication in the key-generation function, which could potentially allow malicious users to execute remote code on affected devices.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-34213", "id": "GSD-2023-34213" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-34213" ], "details": "TN-5900 Series firmware versions v3.3 and prior are vulnerable to command-injection vulnerability. This vulnerability stems from insufficient input validation and improper authentication in the key-generation function, which could potentially allow malicious users to execute remote code on affected devices.\u00a0\n", "id": "GSD-2023-34213", "modified": "2023-12-13T01:20:30.394943Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@moxa.com", "ID": "CVE-2023-34213", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "TN-5900 Series", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "1.0", "version_value": "3.3" } ] } } ] }, "vendor_name": "Moxa" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "TN-5900 Series firmware versions v3.3 and prior are vulnerable to command-injection vulnerability. This vulnerability stems from insufficient input validation and improper authentication in the key-generation function, which could potentially allow malicious users to execute remote code on affected devices.\u00a0\n" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-77", "lang": "eng", "value": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-230402-tn-5900-and-tn-4900-series-web-server-multiple-vulnerabilities", "refsource": "MISC", "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-230402-tn-5900-and-tn-4900-series-web-server-multiple-vulnerabilities" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Moxa has developed appropriate solution to address the vulnerability. The solution for affected products is shown below.\u003cbr\u003e\u003cul\u003e\u003cli\u003eTN-5900 Series: Please upgrade to firmware v3.4 or higher.\u003c/li\u003e\u003c/ul\u003e" } ], "value": "Moxa has developed appropriate solution to address the vulnerability. The solution for affected products is shown below.\n * TN-5900 Series: Please upgrade to firmware v3.4 or higher.\n\n\n" } ], "source": { "discovery": "EXTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:moxa:tn-5900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:moxa:tn-5900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "psirt@moxa.com", "ID": "CVE-2023-34213" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "TN-5900 Series firmware versions v3.3 and prior are vulnerable to command-injection vulnerability. This vulnerability stems from insufficient input validation and improper authentication in the key-generation function, which could potentially allow malicious users to execute remote code on affected devices.\u00a0\n" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-77" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-230402-tn-5900-and-tn-4900-series-web-server-multiple-vulnerabilities", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-230402-tn-5900-and-tn-4900-series-web-server-multiple-vulnerabilities" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2023-08-22T18:51Z", "publishedDate": "2023-08-17T03:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.