GSD-2023-41255

Vulnerability from gsd - Updated: 2023-12-13 01:20
Details
The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication of the ‘su’ binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol exposed on the network.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2023-41255",
    "id": "GSD-2023-41255"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-41255"
      ],
      "details": "The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication \r\nof the \u2018su\u2019 binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol  exposed on the network.",
      "id": "GSD-2023-41255",
      "modified": "2023-12-13T01:20:45.348890Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "psirt@bosch.com",
        "ID": "CVE-2023-41255",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "ctrlX HMI Web Panel - WR21 (WR2107)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "ctrlX HMI Web Panel - WR21 (WR2110)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "ctrlX HMI Web Panel - WR21 (WR2115)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Rexroth"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication \r\nof the \u2018su\u2019 binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol  exposed on the network."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-306",
                "lang": "eng",
                "value": "CWE-306 Missing Authentication for Critical Function"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
            "refsource": "MISC",
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "ID": "CVE-2023-41255"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication \r\nof the \u2018su\u2019 binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol  exposed on the network."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
              "refsource": "MISC",
              "tags": [
                "Mitigation",
                "Vendor Advisory"
              ],
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2023-11-06T14:33Z",
      "publishedDate": "2023-10-25T18:17Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…