gsd-2023-42782
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A insufficient verification of data authenticity vulnerability [CWE-345] in FortiAnalyzer version 7.4.0 and below 7.2.3 allows a remote unauthenticated attacker to send messages to the syslog server of FortiAnalyzer via the knoweldge of an authorized device serial number.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2023-42782",
    "id": "GSD-2023-42782"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-42782"
      ],
      "details": "A insufficient verification of data authenticity vulnerability [CWE-345] in FortiAnalyzer version 7.4.0 and below 7.2.3 allows a remote unauthenticated attacker to send messages to the syslog server of FortiAnalyzer via the knoweldge of an authorized device serial number.",
      "id": "GSD-2023-42782",
      "modified": "2023-12-13T01:20:21.658972Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "psirt@fortinet.com",
        "ID": "CVE-2023-42782",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "FortiAnalyzer",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "7.4.0"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "7.2.0",
                          "version_value": "7.2.3"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "7.0.0",
                          "version_value": "7.0.9"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "6.4.0",
                          "version_value": "6.4.13"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "6.2.0",
                          "version_value": "6.2.12"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Fortinet"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A insufficient verification of data authenticity vulnerability [CWE-345] in FortiAnalyzer version 7.4.0 and below 7.2.3 allows a remote unauthenticated attacker to send messages to the syslog server of FortiAnalyzer via the knoweldge of an authorized device serial number."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:C",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-345",
                "lang": "eng",
                "value": "Improper access control"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://fortiguard.com/psirt/FG-IR-23-221",
            "refsource": "MISC",
            "url": "https://fortiguard.com/psirt/FG-IR-23-221"
          }
        ]
      },
      "solution": [
        {
          "lang": "en",
          "value": "Please upgrade to FortiAnalyzer version 7.4.1 or above\r\nPlease upgrade to FortiAnalyzer version 7.2.4 or above\n\r\nAND\u00a0\nConfigure the \"un-encrypted-logging\" option to disable receiving syslog without encryption through UDP(514) or TCP(514).\nconfig system log setting\r\n\u00a0 \u00a0 set un-encrypted-logging disable"
        }
      ]
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "6.2.12",
                "versionStartIncluding": "6.2.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fortinet:fortianalyzer:7.4.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "7.2.3",
                "versionStartIncluding": "7.2.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "7.0.9",
                "versionStartIncluding": "7.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "6.4.13",
                "versionStartIncluding": "6.4.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@fortinet.com",
          "ID": "CVE-2023-42782"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A insufficient verification of data authenticity vulnerability [CWE-345] in FortiAnalyzer version 7.4.0 and below 7.2.3 allows a remote unauthenticated attacker to send messages to the syslog server of FortiAnalyzer via the knoweldge of an authorized device serial number."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-345"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://fortiguard.com/psirt/FG-IR-23-221",
              "refsource": "MISC",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://fortiguard.com/psirt/FG-IR-23-221"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 1.4
        }
      },
      "lastModifiedDate": "2023-10-13T16:29Z",
      "publishedDate": "2023-10-10T17:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.