GSD-2023-45844
Vulnerability from gsd - Updated: 2023-12-13 01:20Details
The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug).
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-45844",
"id": "GSD-2023-45844"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-45844"
],
"details": "The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug).",
"id": "GSD-2023-45844",
"modified": "2023-12-13T01:20:37.780902Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"ID": "CVE-2023-45844",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ctrlX HMI Web Panel - WR21 (WR2107)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "ctrlX HMI Web Panel - WR21 (WR2110)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "ctrlX HMI Web Panel - WR21 (WR2115)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
}
]
},
"vendor_name": "Rexroth"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug)."
}
]
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-284",
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"refsource": "MISC",
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"ID": "CVE-2023-45844"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"refsource": "MISC",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-11-06T14:39Z",
"publishedDate": "2023-10-25T18:17Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…