gsd-2023-49692
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (All versions < V7.2.2), SCALANCE M804PB (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (Annex A) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (Annex B) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (Annex A) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (Annex B) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (All versions < V7.2.2), SCALANCE M874-2 (All versions < V7.2.2), SCALANCE M874-3 (All versions < V7.2.2), SCALANCE M876-3 (EVDO) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (All versions < V7.2.2), SCALANCE M876-4 (All versions < V7.2.2), SCALANCE M876-4 (EU) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (All versions < V7.2.2), SCALANCE S615 (All versions < V7.2.2), SCALANCE S615 EEC (All versions < V7.2.2). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2023-49692",
    "id": "GSD-2023-49692"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-49692"
      ],
      "details": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (All versions \u003c V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (All versions \u003c V7.2.2), SCALANCE M804PB (All versions \u003c V7.2.2), SCALANCE M812-1 ADSL-Router (Annex A) (All versions \u003c V7.2.2), SCALANCE M812-1 ADSL-Router (Annex B) (All versions \u003c V7.2.2), SCALANCE M816-1 ADSL-Router (Annex A) (All versions \u003c V7.2.2), SCALANCE M816-1 ADSL-Router (Annex B) (All versions \u003c V7.2.2), SCALANCE M826-2 SHDSL-Router (All versions \u003c V7.2.2), SCALANCE M874-2 (All versions \u003c V7.2.2), SCALANCE M874-3 (All versions \u003c V7.2.2), SCALANCE M876-3 (EVDO) (All versions \u003c V7.2.2), SCALANCE M876-3 (ROK) (All versions \u003c V7.2.2), SCALANCE M876-4 (All versions \u003c V7.2.2), SCALANCE M876-4 (EU) (All versions \u003c V7.2.2), SCALANCE M876-4 (NAM) (All versions \u003c V7.2.2), SCALANCE MUM853-1 (EU) (All versions \u003c V7.2.2), SCALANCE MUM856-1 (EU) (All versions \u003c V7.2.2), SCALANCE MUM856-1 (RoW) (All versions \u003c V7.2.2), SCALANCE S615 (All versions \u003c V7.2.2), SCALANCE S615 EEC (All versions \u003c V7.2.2). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established.",
      "id": "GSD-2023-49692",
      "modified": "2023-12-13T01:20:34.946065Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "productcert@siemens.com",
        "ID": "CVE-2023-49692",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "RUGGEDCOM RM1224 LTE(4G) EU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "RUGGEDCOM RM1224 LTE(4G) NAM",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M804PB",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M812-1 ADSL-Router (Annex A)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M812-1 ADSL-Router (Annex B)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M816-1 ADSL-Router (Annex A)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M816-1 ADSL-Router (Annex B)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M826-2 SHDSL-Router",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M874-2",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M874-3",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M876-3 (EVDO)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M876-3 (ROK)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M876-4",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M876-4 (EU)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE M876-4 (NAM)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE MUM853-1 (EU)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE MUM856-1 (EU)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE MUM856-1 (RoW)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE S615",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE S615 EEC",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V7.2.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE SC622-2C",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.0.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE SC626-2C",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.0.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE SC632-2C",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.0.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE SC636-2C",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.0.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE SC642-2C",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.0.2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE SC646-2C",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.0.2"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Siemens"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V7.2.2), SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V7.2.2), SCALANCE S615 (6GK5615-0AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE S615 EEC (6GK5615-0AA01-2AA2) (All versions \u003c V7.2.2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V3.0.2). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-78",
                "lang": "eng",
                "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-068047.pdf",
            "refsource": "MISC",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-068047.pdf"
          },
          {
            "name": "https://cert-portal.siemens.com/productcert/html/ssa-068047.html",
            "refsource": "MISC",
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-068047.html"
          },
          {
            "name": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html",
            "refsource": "MISC",
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk6108-4am00-2ba2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "537B7923-B10A-4293-8015-647E7C0209F4",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk6108-4am00-2ba2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FF17A4F6-6057-4A37-87E7-9BCADD629FF7",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk6108-4am00-2da2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "284B21F4-822B-4EC7-BE03-6D177AAFAA53",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk6108-4am00-2da2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6C6F2102-116D-4488-9FEC-2A97DC6C5964",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5804-0ap00-2aa2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E8452262-C341-4239-974E-9A6B10864592",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5804-0ap00-2aa2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "ABB76E7F-193D-4AFA-A820-A3D93D1AAA32",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5812-1aa00-2aa2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7006300C-93DA-4DC0-92D2-D3738F916E09",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5812-1aa00-2aa2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "374B9F0F-D572-4CB3-8A8C-778AE405E4FA",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5812-1ba00-2aa2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9046E35B-61E7-43C5-9BCB-AE253AA5B219",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5812-1ba00-2aa2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B8A8BB09-B2DC-4F09-A051-FC1ACCA76627",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5816-1aa00-2aa2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AC97692B-79A4-42EA-B982-C601565AD21A",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5816-1aa00-2aa2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A8A090F9-63B9-4C02-8FF5-91A99231434A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5816-1ba00-2aa2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CB9F1347-3286-446A-ACBE-CA23295D1994",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5816-1ba00-2aa2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A1FC0649-5A59-47C3-92F8-22A27EA08495",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5826-2ab00-2ab2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "055CD171-8A39-4B76-A609-9EA6B3269A3A",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5826-2ab00-2ab2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "58C61EFF-461A-4FA0-B851-4B838FC9762F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5874-2aa00-2aa2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E10AD333-1568-45DC-A09C-48D235AED557",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5874-2aa00-2aa2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BA7267C4-1486-49AF-B5F9-2A40DC285E86",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5874-3aa00-2aa2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4065F6CE-953B-4785-ADFE-2F63F56C48DF",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5874-3aa00-2aa2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B82271D5-62F9-4483-A199-AB306F560E70",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5876-3aa02-2ba2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A7CB8ED9-6EDC-4B4D-8354-FBC5588A43C0",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5876-3aa02-2ba2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AAFD5B12-FE85-432D-9169-657E8CA7FDB5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5876-3aa02-2ea2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7F794E16-FB65-4F05-AC22-56728BA074B2",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5876-3aa02-2ea2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F55773A9-F64F-4365-8249-B1500C809D63",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5876-4aa10-2ba2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "01E5DEA4-38E5-4AD8-A963-596449F052E3",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5876-4aa10-2ba2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2BE36DEA-AEF7-4F39-B3C0-52ECBA170333",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5876-4aa00-2ba2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "87989AC8-FD86-4BE2-9235-39738790CE62",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5876-4aa00-2ba2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8040F274-DC42-466F-B13A-4DEA36B351DC",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5876-4aa00-2da2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C09CC3C4-9D27-43FA-8D26-35C2EBD6B6F2",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5876-4aa00-2da2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D28BCB70-1DA2-4C1D-8FA5-B7242163C3DC",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5853-2ea00-2da1_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5D58761E-1E0A-49FF-A32D-8775CDAA3BA8",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5853-2ea00-2da1:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "39CFB4DB-2628-49C8-BEF7-DB0A27FEA286",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5856-2ea00-3da1_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "89266C0A-4556-4C13-AD7A-6D382288E725",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5856-2ea00-3da1:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AD59C631-F68B-4BB1-ACF1-BDE034214B20",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5856-2ea00-3aa1_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2D76F9BF-D064-4DB3-BFF7-1E2B84FE4D8D",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5856-2ea00-3aa1:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D3CE8D68-CCE8-49E8-8229-5D64E5F7C67B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5615-0aa00-2aa2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "68E5790D-4C12-4338-9B1B-711042AF8FBA",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5615-0aa00-2aa2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CF189379-EA02-4FCE-8E85-51C7CFD1674C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:6gk5615-0aa01-2aa2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "87F42B95-6DB4-4448-AFD6-630BE2F7294A",
                    "versionEndExcluding": "7.2.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:6gk5615-0aa01-2aa2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B83CF684-8E84-4ECD-9090-8B8997008108",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V7.2.2), SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V7.2.2), SCALANCE S615 (6GK5615-0AA00-2AA2) (All versions \u003c V7.2.2), SCALANCE S615 EEC (6GK5615-0AA01-2AA2) (All versions \u003c V7.2.2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V3.0.2). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established."
          },
          {
            "lang": "es",
            "value": "Se ha identificado una vulnerabilidad en: \nRUGGEDCOM RM1224 LTE(4G) EU (Todas las versiones \u0026lt; V7.2.2), \nRUGGEDCOM RM1224 LTE(4G) NAM (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE M804PB (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE M812-1 ADSL-Router (Anexo A) (Todas las versiones \u0026lt; V7.2.2),\nSCALANCE M812-1 ADSL-Router (Anexo B) (Todas las versiones \u0026lt; V7.2.2),\nSCALANCE M816-1 ADSL-Router (Anexo A) (Todas las versiones \u0026lt; V7.2.2),\nSCALANCE M816-1 ADSL-Router (Anexo B) (Todas las versiones \u0026lt; V7.2.2),\nSCALANCE M826-2 SHDSL-Router (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE M874-2 ( Todas las versiones \u0026lt; V7.2.2), \nSCALANCE M874-3 (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE M876-3 (EVDO) (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE M876-3 (ROK) (Todas las versiones \u0026lt; V7. 2.2), \nSCALANCE M876-4 (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE M876-4 (EU) (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE M876-4 (NAM) (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE MUM853 -1 (UE) (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE MUM856-1 (UE) (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE MUM856-1 (RoW) (Todas las versiones \u0026lt; V7.2.2), \nSCALANCE S615 (Todas versiones \u0026lt; V7.2.2), \nSCALANCE S615 EEC (Todas las versiones \u0026lt; V7.2.2). \nExiste una vulnerabilidad de neutralizaci\u00f3n inadecuada de elementos especiales utilizados en un comando del sistema operativo con privilegios de root en el an\u00e1lisis de la configuraci\u00f3n IPSEC. Esto podr\u00eda permitir que administradores locales malintencionados emitan comandos a nivel del sistema despu\u00e9s de que se establezca una nueva conexi\u00f3n."
          }
        ],
        "id": "CVE-2023-49692",
        "lastModified": "2024-02-13T09:15:46.507",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 0.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 5.9,
              "source": "productcert@siemens.com",
              "type": "Secondary"
            }
          ]
        },
        "published": "2023-12-12T12:15:16.203",
        "references": [
          {
            "source": "productcert@siemens.com",
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-068047.html"
          },
          {
            "source": "productcert@siemens.com",
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html"
          },
          {
            "source": "productcert@siemens.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-068047.pdf"
          }
        ],
        "sourceIdentifier": "productcert@siemens.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "productcert@siemens.com",
            "type": "Primary"
          }
        ]
      }
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.