gsd-2024-1453
Vulnerability from gsd
Modified
2024-02-13 06:02
Details
In Sante DICOM Viewer Pro versions 14.0.3 and prior, a user must open a malicious DICOM file, which could allow a local attacker to disclose information or execute arbitrary code.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-1453" ], "details": "\nIn Sante DICOM Viewer Pro versions 14.0.3 and prior, a user must open a malicious DICOM file, which could allow a local attacker to disclose information or execute arbitrary code.\n\n", "id": "GSD-2024-1453", "modified": "2024-02-13T06:02:27.317814Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2024-1453", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Sante DICOM Viewer Pro", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "14.0.3" } ] } } ] }, "vendor_name": "Santesoft" } ] } }, "credits": [ { "lang": "en", "value": "Michael Heinzl reported this vulnerability to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "\nIn Sante DICOM Viewer Pro versions 14.0.3 and prior, a user must open a malicious DICOM file, which could allow a local attacker to disclose information or execute arbitrary code.\n\n" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-125", "lang": "eng", "value": "CWE-125 Out-of-bounds Read" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-058-01", "refsource": "MISC", "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-058-01" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSantesoft released an updated version of their product and recommends updating Sante DICOM Viewer Pro to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://santesoft.com/win/sante-dicom-viewer-pro/download.html\"\u003ev14.0.4\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "\nSantesoft released an updated version of their product and recommends updating Sante DICOM Viewer Pro to v14.0.4 https://santesoft.com/win/sante-dicom-viewer-pro/download.html \u00a0or later.\n\n\n" } ], "source": { "advisory": "ICSMA-24-058-01", "discovery": "EXTERNAL" } }, "nvd.nist.gov": { "cve": { "descriptions": [ { "lang": "en", "value": "\nIn Sante DICOM Viewer Pro versions 14.0.3 and prior, a user must open a malicious DICOM file, which could allow a local attacker to disclose information or execute arbitrary code.\n\n" } ], "id": "CVE-2024-1453", "lastModified": "2024-03-01T22:22:25.913", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" } ] }, "published": "2024-03-01T19:15:07.037", "references": [ { "source": "ics-cert@hq.dhs.gov", "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-058-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Awaiting Analysis", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "ics-cert@hq.dhs.gov", "type": "Primary" } ] } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.