gsd-2024-21846
Vulnerability from gsd
Modified
2024-01-06 06:02
Details
An unauthenticated attacker can reset the board and stop transmitter
operations by sending a specially-crafted GET request to the command.cgi
gateway, resulting in a denial-of-service scenario.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-21846" ], "details": "\nAn unauthenticated attacker can reset the board and stop transmitter \noperations by sending a specially-crafted GET request to the command.cgi\n gateway, resulting in a denial-of-service scenario.\n\n", "id": "GSD-2024-21846", "modified": "2024-01-06T06:02:13.219106Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2024-21846", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Compact DAB Transmitter", "version": { "version_data": [ { "version_affected": "=", "version_value": "10W" }, { "version_affected": "=", "version_value": "100W" }, { "version_affected": "=", "version_value": "250W" } ] } }, { "product_name": "Medium DAB Transmitter", "version": { "version_data": [ { "version_affected": "=", "version_value": "500W" }, { "version_affected": "=", "version_value": "1kW" }, { "version_affected": "=", "version_value": "2kW" } ] } }, { "product_name": "High Power DAB Transmitter", "version": { "version_data": [ { "version_affected": "=", "version_value": "2.5kW" }, { "version_affected": "=", "version_value": "3kW" }, { "version_affected": "=", "version_value": "4kW" }, { "version_affected": "=", "version_value": "5kW " } ] } }, { "product_name": "Compact FM Transmitter", "version": { "version_data": [ { "version_affected": "=", "version_value": "Compact FM Transmitter" }, { "version_affected": "=", "version_value": "500W" }, { "version_affected": "=", "version_value": "1kW" }, { "version_affected": "=", "version_value": "2kW " } ] } }, { "product_name": "Modular FM Transmitter", "version": { "version_data": [ { "version_affected": "=", "version_value": "3kW" }, { "version_affected": "=", "version_value": "5kW" }, { "version_affected": "=", "version_value": "10kW" }, { "version_affected": "=", "version_value": "15kW" }, { "version_affected": "=", "version_value": "20kW" }, { "version_affected": "=", "version_value": "30kW " } ] } }, { "product_name": "Digital FM Transmitter", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "15W ", "version_value": "40kW " } ] } }, { "product_name": "VHF TV Transmitter", "version": { "version_data": [ { "version_affected": "=", "version_value": "BI" }, { "version_affected": "=", "version_value": "BIII " } ] } }, { "product_name": "UHF TV Transmitter", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "10W ", "version_value": "5kW " } ] } } ] }, "vendor_name": "Electrolink " } ] } }, "credits": [ { "lang": "en", "value": "Gjoko Krstic publicly reported these vulnerabilities on the internet after an unsuccessful attempt to contact Electrolink directly." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "\nAn unauthenticated attacker can reset the board and stop transmitter \noperations by sending a specially-crafted GET request to the command.cgi\n gateway, resulting in a denial-of-service scenario.\n\n" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-306", "lang": "eng", "value": "CWE-306 Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02", "refsource": "MISC", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02" } ] }, "source": { "advisory": "ICSA-24-107-02", "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\nElectrolink has not responded to requests to work with CISA to mitigate \nthese vulnerabilities. Users of the affected products are encouraged to \ncontact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://electrolink.com/contacts/\"\u003eElectrolink\u003c/a\u003e for additional information.\n\n\u003cbr\u003e" } ], "value": "Electrolink has not responded to requests to work with CISA to mitigate \nthese vulnerabilities. Users of the affected products are encouraged to \ncontact Electrolink https://electrolink.com/contacts/ for additional information.\n\n" } ] }, "nvd.nist.gov": { "cve": { "descriptions": [ { "lang": "en", "value": "\nAn unauthenticated attacker can reset the board and stop transmitter \noperations by sending a specially-crafted GET request to the command.cgi\n gateway, resulting in a denial-of-service scenario.\n\n" } ], "id": "CVE-2024-21846", "lastModified": "2024-04-19T13:10:25.637", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" } ] }, "published": "2024-04-18T23:15:06.933", "references": [ { "source": "ics-cert@hq.dhs.gov", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Awaiting Analysis", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "ics-cert@hq.dhs.gov", "type": "Primary" } ] } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.