GSD-2024-3881
Vulnerability from gsd - Updated: 2024-04-17 05:02Details
A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Aliases
{
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2024-3881"
],
"details": "A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.",
"id": "GSD-2024-3881",
"modified": "2024-04-17T05:02:01.747944Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cna@vuldb.com",
"ID": "CVE-2024-3881",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "W30E",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "1.0.1.25(633)"
}
]
}
}
]
},
"vendor_name": "Tenda"
}
]
}
},
"credits": [
{
"lang": "en",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "deu",
"value": "Eine kritische Schwachstelle wurde in Tenda W30E 1.0.1.25(633) gefunden. Davon betroffen ist die Funktion frmL7PlotForm der Datei /goform/frmL7ProtForm. Mittels Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
]
},
"impact": {
"cvss": [
{
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-121",
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://vuldb.com/?id.260915",
"refsource": "MISC",
"url": "https://vuldb.com/?id.260915"
},
{
"name": "https://vuldb.com/?ctiid.260915",
"refsource": "MISC",
"url": "https://vuldb.com/?ctiid.260915"
},
{
"name": "https://vuldb.com/?submit.312824",
"refsource": "MISC",
"url": "https://vuldb.com/?submit.312824"
},
{
"name": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/frmL7ProtForm.md",
"refsource": "MISC",
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/frmL7ProtForm.md"
}
]
}
},
"nvd.nist.gov": {
"cve": {
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Una vulnerabilidad fue encontrada en Tenda W30E 1.0.1.25(633) y clasificada como cr\u00edtica. Este problema afecta la funci\u00f3n frmL7PlotForm del archivo /goform/frmL7ProtForm. La manipulaci\u00f3n de la p\u00e1gina de argumentos provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-260915. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
}
],
"id": "CVE-2024-3881",
"lastModified": "2024-04-17T12:48:31.863",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cna@vuldb.com",
"type": "Secondary"
}
]
},
"published": "2024-04-16T20:15:10.280",
"references": [
{
"source": "cna@vuldb.com",
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/frmL7ProtForm.md"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?ctiid.260915"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?id.260915"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?submit.312824"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
}
]
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…