gsd-2024-4170
Vulnerability from gsd
Modified
2024-04-26 05:02
Details
A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Aliases



{
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2024-4170"
      ],
      "details": "A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.",
      "id": "GSD-2024-4170",
      "modified": "2024-04-26T05:02:17.362844Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cna@vuldb.com",
        "ID": "CVE-2024-4170",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "4G300",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "1.01.42"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Tenda"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "deu",
            "value": "Eine Schwachstelle wurde in Tenda 4G300 1.01.42 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion sub_429A30. Mit der Manipulation des Arguments list1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-121",
                "lang": "eng",
                "value": "CWE-121 Stack-based Buffer Overflow"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://vuldb.com/?id.261989",
            "refsource": "MISC",
            "url": "https://vuldb.com/?id.261989"
          },
          {
            "name": "https://vuldb.com/?ctiid.261989",
            "refsource": "MISC",
            "url": "https://vuldb.com/?ctiid.261989"
          },
          {
            "name": "https://vuldb.com/?submit.318991",
            "refsource": "MISC",
            "url": "https://vuldb.com/?submit.318991"
          },
          {
            "name": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md",
            "refsource": "MISC",
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          }
        ],
        "id": "CVE-2024-4170",
        "lastModified": "2024-04-25T13:18:02.660",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ]
        },
        "published": "2024-04-25T13:15:51.993",
        "references": [
          {
            "source": "cna@vuldb.com",
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?ctiid.261989"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?id.261989"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?submit.318991"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-121"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Primary"
          }
        ]
      }
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.