ICSA-19-008-02
Vulnerability from csaf_cisa - Published: 2019-01-08 00:00 - Updated: 2019-01-15 00:00Summary
Schneider Electric IIoT Monitor (Update A)
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Critical infrastructure sectors
Commercial Facilities, Critical Manufacturing, Energy, Transportation Services
Countries/areas deployed
Worldwide
Company headquarters location
France
Recommended Practices
NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.
Recommended Practices
NCCIC also recommends that users take the following measures to protect themselves from social engineering attacks:
Exploitability
No known public exploits specifically target these vulnerabilities.
{
"document": {
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro \u0027s Zero Day Initiative",
"summary": "reporting these vulnerabilities to NCCIC"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "Commercial Facilities, Critical Manufacturing, Energy, Transportation Services",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "NCCIC also recommends that users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-19-008-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-008-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-008-02 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-008-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-008-02"
}
],
"title": "Schneider Electric IIoT Monitor (Update A)",
"tracking": {
"current_release_date": "2019-01-15T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-008-02",
"initial_release_date": "2019-01-08T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-01-08T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-19-008-02 Schneider Electric IIoT Monitor"
},
{
"date": "2019-01-15T00:00:00.000000Z",
"legacy_version": "A",
"number": "2",
"summary": "ICSA-19-008-02 Schneider Electric IIoT Monitor (Update A)"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 3.1.38",
"product": {
"name": "IIoT Monitor: Versions 3.1.38 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "IIoT Monitor"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-7835",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A path traversal vulnerability exists, which may allow access to files available to SYSTEM user.CVE-2018-7835 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7835"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends that affected users contact Schneider Electric customer support at https://www.schneider-electric.com/en/work/support/contacts.jsp for assistance in migrating to the latest software to resolve the issues.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Schneider Electric has also released a security notification ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/"
},
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends implementing industry cybersecurity best practices",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment or the ICS and safety networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices that it is intended.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. should be scanned before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2018-7836",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "summary",
"text": "An unrestricted upload of a file with dangerous type vulnerability exists in the IIoT Monitor software that could allow the uploading and execution of malicious files.CVE-2018-7836 has been assigned to this vulnerability. A CVSS v3 base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7836"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends that affected users contact Schneider Electric customer support at https://www.schneider-electric.com/en/work/support/contacts.jsp for assistance in migrating to the latest software to resolve the issues.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Schneider Electric has also released a security notification ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/"
},
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends implementing industry cybersecurity best practices",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment or the ICS and safety networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices that it is intended.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. should be scanned before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2018-7837",
"cwe": {
"id": "CWE-611",
"name": "Improper Restriction of XML External Entity Reference"
},
"notes": [
{
"category": "summary",
"text": "There is an XXE vulnerability in the IIoT Monitor software that may allow the software to resolve documents outside of the intended sphere of control, causing the software to embed incorrect documents into its output and expose restricted information.CVE-2018-7837 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7837"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends that affected users contact Schneider Electric customer support at https://www.schneider-electric.com/en/work/support/contacts.jsp for assistance in migrating to the latest software to resolve the issues.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Schneider Electric has also released a security notification ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/"
},
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends implementing industry cybersecurity best practices",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment or the ICS and safety networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices that it is intended.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. should be scanned before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2018-7839",
"cwe": {
"id": "CWE-326",
"name": "Inadequate Encryption Strength"
},
"notes": [
{
"category": "summary",
"text": "There is a hardcoded cryptographic key that may affect the confidentiality of the device.CVE-2018-7839 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7839"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends that affected users contact Schneider Electric customer support at https://www.schneider-electric.com/en/work/support/contacts.jsp for assistance in migrating to the latest software to resolve the issues.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Schneider Electric has also released a security notification ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/"
},
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends implementing industry cybersecurity best practices",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment or the ICS and safety networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices that it is intended.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. should be scanned before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…