Summary
PLC Cycle Time Influences (Update A)
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
High network load can consume CPU power in such a way that the normal operation of the device can be affected; that is, the configured cycle time can be influenced.
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "High network load can consume CPU power in such a way that the normal operation of the device can be affected; that is, the configured cycle time can be influenced.", "title": "Risk evaluation" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-106-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-106-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-106-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-106-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "PLC Cycle Time Influences (Update A)", "tracking": { "current_release_date": "2019-12-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-106-03", "initial_release_date": "2019-04-16T00:00:00.000000Z", "revision_history": [ { "date": "2019-04-16T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-106-03 PLC Cycle Time Influences" }, { "date": "2019-12-12T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-19-106-03 PLC Cycle Time Influences (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 01.07.13(10)", "product": { "name": "WAGO 750-889 Controller: KNX IP", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "750-889 Controller" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "Phoenix Contact: ILC 191 ETH 2TX", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "ILC 191 ETH 2TX" }, { "branches": [ { "category": "product_version", "name": "S7-1211", "product": { "name": "Siemens: 6ES7211-1AE40-0XB0 Simatic S7-1211", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "6ES7211-1AE40-0XB0" }, { "branches": [ { "category": "product_version", "name": "S7-314", "product": { "name": "Siemens: 6ES7314-6EH04-0AB0 Simatic S7-314", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "ES7314-6EH04-0AB0" }, { "branches": [ { "category": "product_version", "name": "8", "product": { "name": "Siemens: 6ED1052-1CC01-0BA8 Logo! 8", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "6ED1052-1CC01-0BA8" }, { "branches": [ { "category": "product_version", "name": "PM554-TP-ETH", "product": { "name": "ABB: 1SAP120600R0071 PM554-TP-ETH", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "1SAP120600R0071" }, { "branches": [ { "category": "product_version_range", "name": "\u003c= 02.05.23(08)", "product": { "name": "WAGO 750-8100 Controller: PFC100", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "750-8100 Controller" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "Phoenix Contact: 2700974 ILC 151 ETH", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "2700974 ILC 151 ETH" }, { "branches": [ { "category": "product_version_range", "name": "\u003c= 01.07.03(10)", "product": { "name": "WAGO 750-880 Controller: ETH", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "750-880 Controller" }, { "branches": [ { "category": "product_version_range", "name": "\u003c= 01.02.29(09)", "product": { "name": "WAGO 750-831 Controller: BACnet/IP", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "750-831 Controller" }, { "branches": [ { "category": "product_version", "name": "M221", "product": { "name": "Schneider: Modicon M221", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "Modicron" } ], "category": "vendor", "name": "ABB, Phoenix Contact, Schneider Electric, Siemens, and WAGO" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-10953", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.CVE-2019-10953 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10953" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "PLC vendors have responded to queries about this report with the following mitigations:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] }, { "category": "vendor_fix", "details": "ABB concludes the reported behavior is not a vulnerability but is due to a misconfiguration of the PLC watchdog, which was left in the default factory settings. This has led to a configuration that does not match the expectations expressed in the test cases and the result is the PLC not reacting as intended. This misconfiguration can be fixed by setting an appropriate combination of task priority, task cycle time, and watchdog settings. Please see the Onboard Ethernet Handling in CPU Firmware chapter (System Technology for AC500 V2 Products \u003e System Technology of CPU and Overall System \u003e Onboard Technologies \u003e Ethernet \u003e Ethernet Protocols and Ports for AC500 V2 Products \u003e Onboard Ethernet Handling in CPU Firmware) for further guidance.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] }, { "category": "vendor_fix", "details": "Phoenix Contact acknowledges this as a known, won \u0027t fix issue for old products. Currently available products provide countermeasures to mitigate the impact on the safety-related functionality. Phoenix Contact urges users to adhere to theApplication note 107913_en_01.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "vendor_fix", "details": "More information can be found in the VDE CERT advisory.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ], "url": "https://cert.vde.com/en-us/advisories/vde-2018-012" }, { "category": "vendor_fix", "details": "Fixes are available in the Modicon M221 firmware v1.10.0.0 and the EcoStruxure Machine Expert - Basic v1.0 software (formerly SoMachine Basic) using either of the following options:Use this link to download the Machine Expert Basic software.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ], "url": "https://www.schneider-electric.com/en/download/document/Machine_Expert_Basic" }, { "category": "vendor_fix", "details": "Or run the Schneider Electric Software Update tool in order to download and install EcoStruxure Machine Expert - Basic v1.0 software.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] }, { "category": "vendor_fix", "details": "For additional information, see the Schneider Electric security notice SEVD-2019-045-01.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ], "url": "https://www.schneider-electric.com/en/download/document/%20SEVD-2019-045-01/" }, { "category": "vendor_fix", "details": "Schneider Electric strongly recommends following industry cybersecurity best practices, such as:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] }, { "category": "vendor_fix", "details": "Siemens has investigated the vulnerability report on PLC cycle time influences and concludes the report does not demonstrate a valid vulnerability for Siemens PLCs.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] }, { "category": "vendor_fix", "details": "WAGO recommends users operate the devices in closed networks or protect them with a firewall against unauthorized access. Another recommended mitigation is to limit network traffic via the switch rate limit feature according to application needs.\nPlease also consult the product manuals on the WAGO website, as this is a known problem for some devices. Links to product manuals and specific instructions about how to limit switch rates can be found in the VDE CERT advisory.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ], "url": "https://cert.vde.com/de-de/advisories/vde-2018-013" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] } ] } ] }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.