icsa-21-068-03
Vulnerability from csaf_cisa
Published
2021-03-09 00:00
Modified
2021-04-13 00:00
Summary
Siemens SCALANCE and RUGGEDCOM Devices (Update A)
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of this vulnerability could allow an attacker to cause a reboot. Under specific circumstances, an attacker could also achieve remote code execution of the affected devices.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Exploitability
No known public exploits specifically target this vulnerability.
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow an attacker to cause a reboot. Under specific circumstances, an attacker could also achieve remote code execution of the affected devices.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-979775: Stack Overflow Vulnerability in SCALANCE and RUGGEDCOM Devices - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-979775.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-068-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-068-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-068-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-068-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-979775: Stack Overflow Vulnerability in SCALANCE and RUGGEDCOM Devices - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf" }, { "category": "external", "summary": "SSA-979775: Stack Overflow Vulnerability in SCALANCE and RUGGEDCOM Devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-979775.txt" } ], "title": "Siemens SCALANCE and RUGGEDCOM Devices (Update A)", "tracking": { "current_release_date": "2021-04-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-068-03", "initial_release_date": "2021-03-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-03-09T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-068-03 Siemens SCALANCE and RUGGEDCOM Devices" }, { "date": "2021-04-13T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-21-068-03 Siemens SCALANCE and RUGGEDCOM Devices (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003e= V4.3 and \u003c V6.4", "product": { "name": "RUGGEDCOM RM1224", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "RUGGEDCOM RM1224" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= V4.3 and \u003c V6.4", "product": { "name": "SCALANCE M-800", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SCALANCE M-800" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= V4.3 and \u003c V6.4", "product": { "name": "SCALANCE S615", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SCALANCE S615" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= V2.0 and \u003c V2.1.3", "product": { "name": "SCALANCE SC-600 Family", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "SCALANCE SC-600 Family" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1", "product": { "name": "SCALANCE XB-200", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "SCALANCE XB-200" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1", "product": { "name": "SCALANCE XC-200", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SCALANCE XC-200" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1", "product": { "name": "SCALANCE XF-200BA", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "SCALANCE XF-200BA" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V6.2", "product": { "name": "SCALANCE XM400", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "SCALANCE XM400" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1", "product": { "name": "SCALANCE XP-200", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "SCALANCE XP-200" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V6.2", "product": { "name": "SCALANCE XR500", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "SCALANCE XR500" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1", "product": { "name": "SCALANCE XR-300WG", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "SCALANCE XR-300WG" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-25667", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution.\n\nSuccessful exploitation requires the passive listening feature of the device to be active.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] }, "references": [ { "summary": "CVE-2021-25667 - RUGGEDCOM RM1224", "url": "https://support.industry.siemens.com/cs/ww/en/view/109794349/" }, { "summary": "CVE-2021-25667 - SCALANCE M-800", "url": "https://support.industry.siemens.com/cs/ww/en/view/109794349/" }, { "summary": "CVE-2021-25667 - SCALANCE S615", "url": "https://support.industry.siemens.com/cs/ww/en/view/109794349/" }, { "summary": "CVE-2021-25667 - SCALANCE SC-600 Family", "url": "https://support.industry.siemens.com/cs/ww/en/view/109793041/" }, { "summary": "CVE-2021-25667 - SCALANCE XB-200", "url": "https://support.industry.siemens.com/cs/ww/en/view/109762982/" }, { "summary": "CVE-2021-25667 - SCALANCE XC-200", "url": "https://support.industry.siemens.com/cs/ww/en/view/109762982/" }, { "summary": "CVE-2021-25667 - SCALANCE XF-200BA", "url": "https://support.industry.siemens.com/cs/ww/en/view/109762982/" }, { "summary": "CVE-2021-25667 - SCALANCE XM400", "url": "https://support.industry.siemens.com/cs/ww/en/view/109764409/" }, { "summary": "CVE-2021-25667 - SCALANCE XP-200", "url": "https://support.industry.siemens.com/cs/ww/en/view/109762982/" }, { "summary": "CVE-2021-25667 - SCALANCE XR500", "url": "https://support.industry.siemens.com/cs/ww/en/view/109761425/" }, { "summary": "CVE-2021-25667 - SCALANCE XR-300WG", "url": "https://support.industry.siemens.com/cs/ww/en/view/109762982/" }, { "summary": "CVE-2021-25667 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25667.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25667" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V6.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109794349/" }, { "category": "vendor_fix", "details": "Update to V2.1.3 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109793041/" }, { "category": "vendor_fix", "details": "Update to V4.1 or later version", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0009", "CSAFPID-00011" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109762982/" }, { "category": "vendor_fix", "details": "Update to V6.2 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109764409/" }, { "category": "vendor_fix", "details": "Update to V6.2 or later version", "product_ids": [ "CSAFPID-00010" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109761425/" }, { "category": "mitigation", "details": "Deactivate the STP passive listening feature of the vulnerable devices", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011" ] } ], "title": "CVE-2021-25667" } ] }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.