icsa-21-313-03
Vulnerability from csaf_cisa
Published
2021-11-09 00:00
Modified
2021-11-09 00:00
Summary
Siemens Nucleus RTOS TCP/IP Stack
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could cause a denial-of-service condition, allow an information leakage, or remote code execution.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Exploitability
No known public exploits specifically target these vulnerabilities.
{ "document": { "acknowledgments": [ { "names": [ "Daniel dos Santos", "Stanislav Dashevskyi", "Amine Amri" ], "organization": "Forescout Research Labs", "summary": "reporting these vulnerabilities to CISA" }, { "names": [ "Uriel Malin", "Tal Zohar" ], "organization": "Medigate", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could cause a denial-of-service condition, allow an information leakage, or remote code execution.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-044112: Multiple Vulnerabilities (NUCLEUS:13) in the TCP/IP Stack of Nucleus RTOS - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-044112.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-313-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-313-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-313-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-313-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-044112: Multiple Vulnerabilities (NUCLEUS:13) in the TCP/IP Stack of Nucleus RTOS - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "category": "external", "summary": "SSA-044112: Multiple Vulnerabilities (NUCLEUS:13) in the TCP/IP Stack of Nucleus RTOS - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-044112.txt" } ], "title": "Siemens Nucleus RTOS TCP/IP Stack", "tracking": { "current_release_date": "2021-11-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-313-03", "initial_release_date": "2021-11-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-11-09T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-313-03 Siemens Nucleus RTOS TCP-IP Stack " } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Nucleus NET", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Nucleus NET" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2017.02.4", "product": { "name": "Nucleus ReadyStart V3", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Nucleus ReadyStart V3" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.1", "product": { "name": "Nucleus ReadyStart V4", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Nucleus ReadyStart V4" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Nucleus Source Code", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Nucleus Source Code" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-31344", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31344 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31344 - Nucleus ReadyStart V4", "url": "https://support.sw.siemens.com/en-US/product/1336134128/" }, { "summary": "CVE-2021-31344 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31344.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31344" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Update to V4.1.1 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/en-US/product/1336134128/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2021-31344" }, { "cve": "CVE-2021-31345", "cwe": { "id": "CWE-1284", "name": "Improper Validation of Specified Quantity in Input" }, "notes": [ { "category": "summary", "text": "The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31345 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31345 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31345.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31345" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2021-31345" }, { "cve": "CVE-2021-31346", "cwe": { "id": "CWE-1284", "name": "Improper Validation of Specified Quantity in Input" }, "notes": [ { "category": "summary", "text": "The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31346 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31346 - Nucleus ReadyStart V4", "url": "https://support.sw.siemens.com/en-US/product/1336134128/" }, { "summary": "CVE-2021-31346 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31346.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31346" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Update to V4.1.1 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/en-US/product/1336134128/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2021-31346" }, { "cve": "CVE-2021-31881", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31881 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31881 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31881.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31881" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2021-31881" }, { "cve": "CVE-2021-31882", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31882 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31882 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31882.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31882" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2021-31882" }, { "cve": "CVE-2021-31883", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31883 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31883 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31883.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31883" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2021-31883" }, { "cve": "CVE-2021-31884", "cwe": { "id": "CWE-170", "name": "Improper Null Termination" }, "notes": [ { "category": "summary", "text": "The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31884 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31884 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31884.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31884" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2021-31884" }, { "cve": "CVE-2021-31885", "cwe": { "id": "CWE-805", "name": "Buffer Access with Incorrect Length Value" }, "notes": [ { "category": "summary", "text": "TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31885 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31885 - Nucleus ReadyStart V4", "url": "https://support.sw.siemens.com/en-US/product/1336134128/" }, { "summary": "CVE-2021-31885 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31885.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31885" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Update to V4.1.1 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/en-US/product/1336134128/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2021-31885" }, { "cve": "CVE-2021-31886", "cwe": { "id": "CWE-170", "name": "Improper Null Termination" }, "notes": [ { "category": "summary", "text": "FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31886 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31886 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31886.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31886" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2021-31886" }, { "cve": "CVE-2021-31887", "cwe": { "id": "CWE-170", "name": "Improper Null Termination" }, "notes": [ { "category": "summary", "text": "FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31887 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31887 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31887.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31887" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2021-31887" }, { "cve": "CVE-2021-31888", "cwe": { "id": "CWE-170", "name": "Improper Null Termination" }, "notes": [ { "category": "summary", "text": "FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31888 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31888 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31888.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31888" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2021-31888" }, { "cve": "CVE-2021-31889", "cwe": { "id": "CWE-191", "name": "Integer Underflow (Wrap or Wraparound)" }, "notes": [ { "category": "summary", "text": "Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31889 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31889 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31889.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31889" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2021-31889" }, { "cve": "CVE-2021-31890", "cwe": { "id": "CWE-240", "name": "Improper Handling of Inconsistent Structural Elements" }, "notes": [ { "category": "summary", "text": "The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2021-31890 - Nucleus ReadyStart V3", "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "summary": "CVE-2021-31890 - Nucleus ReadyStart V4", "url": "https://support.sw.siemens.com/en-US/product/1336134128/" }, { "summary": "CVE-2021-31890 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31890.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31890" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Update to the latest version of Nucleus ReadyStart V3 or V4", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Contact customer support or your local Nucleus Sales team for mitigation advice", "product_ids": [ "CSAFPID-0001" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2017.02.4 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/1009925838/" }, { "category": "vendor_fix", "details": "Update to V4.1.1 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/en-US/product/1336134128/" }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information", "product_ids": [ "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2021-31890" } ] }
cve-2021-31882
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.782Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Capital VSTAR", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with enabled Ethernet options" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:32", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31882", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Capital VSTAR", "version": { "version_data": [ { "version_value": "All versions with enabled Ethernet options" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31882", "datePublished": "2021-11-09T11:31:55", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.782Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31344
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 22:55
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T22:55:53.529Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Capital VSTAR", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with enabled Ethernet options" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus ReadyStart V4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "PLUSCONTROL 1st Gen", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMOTICS CONNECT 400", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V0.5.0.0" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-843", "description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:27", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31344", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Capital VSTAR", "version": { "version_data": [ { "version_value": "All versions with enabled Ethernet options" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus ReadyStart V4", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.1" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "PLUSCONTROL 1st Gen", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMOTICS CONNECT 400", "version": { "version_data": [ { "version_value": "All versions \u003c V0.5.0.0" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31344", "datePublished": "2021-11-09T11:31:51", "dateReserved": "2021-04-15T00:00:00", "dateUpdated": "2024-08-03T22:55:53.529Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31885
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.607Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus ReadyStart V4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "PLUSCONTROL 1st Gen", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-805", "description": "CWE-805: Buffer Access with Incorrect Length Value", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:34", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31885", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus ReadyStart V4", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.1" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "PLUSCONTROL 1st Gen", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-805: Buffer Access with Incorrect Length Value" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31885", "datePublished": "2021-11-09T11:31:58", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.607Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31345
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 22:55
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T22:55:53.688Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Capital VSTAR", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with enabled Ethernet options" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "PLUSCONTROL 1st Gen", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1284", "description": "CWE-1284: Improper Validation of Specified Quantity in Input", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:29", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31345", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Capital VSTAR", "version": { "version_data": [ { "version_value": "All versions with enabled Ethernet options" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "PLUSCONTROL 1st Gen", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-1284: Improper Validation of Specified Quantity in Input" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31345", "datePublished": "2021-11-09T11:31:52", "dateReserved": "2021-04-15T00:00:00", "dateUpdated": "2024-08-03T22:55:53.688Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31889
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-03 23:10
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.703Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Capital VSTAR", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with enabled Ethernet options" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "PLUSCONTROL 1st Gen", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMOTICS CONNECT 400", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V0.5.0.0" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-191", "description": "CWE-191: Integer Underflow (Wrap or Wraparound)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:38", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31889", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Capital VSTAR", "version": { "version_data": [ { "version_value": "All versions with enabled Ethernet options" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "PLUSCONTROL 1st Gen", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMOTICS CONNECT 400", "version": { "version_data": [ { "version_value": "All versions \u003c V0.5.0.0" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-191: Integer Underflow (Wrap or Wraparound)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31889", "datePublished": "2021-11-09T11:32:01", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.703Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31883
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.182Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Capital VSTAR", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with enabled Ethernet options" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:33", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31883", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Capital VSTAR", "version": { "version_data": [ { "version_value": "All versions with enabled Ethernet options" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31883", "datePublished": "2021-11-09T11:31:56", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.182Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31888
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-03 23:10
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.804Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-170", "description": "CWE-170: Improper Null Termination", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:37", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31888", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-170: Improper Null Termination" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31888", "datePublished": "2021-11-09T11:32:00", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.804Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31884
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.775Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Capital VSTAR", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with enabled Ethernet options" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-170", "description": "CWE-170: Improper Null Termination", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:33", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31884", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Capital VSTAR", "version": { "version_data": [ { "version_value": "All versions with enabled Ethernet options" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-170: Improper Null Termination" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31884", "datePublished": "2021-11-09T11:31:57", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.775Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31890
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-03 23:10
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.798Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Capital VSTAR", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with enabled Ethernet options" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus ReadyStart V4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "PLUSCONTROL 1st Gen", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMOTICS CONNECT 400", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V0.5.0.0" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-240", "description": "CWE-240: Improper Handling of Inconsistent Structural Elements", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:39", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31890", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Capital VSTAR", "version": { "version_data": [ { "version_value": "All versions with enabled Ethernet options" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus ReadyStart V4", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.1" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "PLUSCONTROL 1st Gen", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMOTICS CONNECT 400", "version": { "version_data": [ { "version_value": "All versions \u003c V0.5.0.0" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-240: Improper Handling of Inconsistent Structural Elements" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31890", "datePublished": "2021-11-09T11:32:02", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.798Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31887
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-03 23:10
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.650Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-170", "description": "CWE-170: Improper Null Termination", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:36", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31887", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-170: Improper Null Termination" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31887", "datePublished": "2021-11-09T11:32:00", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.650Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31881
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.649Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Capital VSTAR", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with enabled Ethernet options" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:31", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31881", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Capital VSTAR", "version": { "version_data": [ { "version_value": "All versions with enabled Ethernet options" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-125: Out-of-bounds Read" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31881", "datePublished": "2021-11-09T11:31:54", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.649Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31886
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.838Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-170", "description": "CWE-170: Improper Null Termination", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:35", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31886", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-170: Improper Null Termination" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31886", "datePublished": "2021-11-09T11:31:59", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.838Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31346
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 22:55
Severity
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)
References
URL | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf | x_refsource_MISC |
https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T22:55:53.543Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "APOGEE MBC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MBC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE MEC (PPC) (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.19" } ] }, { "product": "Capital VSTAR", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with enabled Ethernet options" } ] }, { "product": "Desigo PXC00-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC00-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC001-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC100-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC12-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC128-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC200-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC22.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC36.1-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC50-E.D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXC64-U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Desigo PXM20-E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] }, { "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Nucleus ReadyStart V3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2017.02.4" } ] }, { "product": "Nucleus ReadyStart V4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1" } ] }, { "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "PLUSCONTROL 1st Gen", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMOTICS CONNECT 400", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V0.5.0.0" } ] }, { "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] }, { "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1284", "description": "CWE-1284: Improper Validation of Specified Quantity in Input", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:30", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31346", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APOGEE MBC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MBC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (BACnet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE MEC (PPC) (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "APOGEE PXC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Compact (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "APOGEE PXC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "APOGEE PXC Modular (P2 Ethernet)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.19" } ] } }, { "product_name": "Capital VSTAR", "version": { "version_data": [ { "version_value": "All versions with enabled Ethernet options" } ] } }, { "product_name": "Desigo PXC00-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC00-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC001-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC100-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC12-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC128-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC200-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC22.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC36.1-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC50-E.D", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXC64-U", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Desigo PXM20-E", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016" } ] } }, { "product_name": "Nucleus NET", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Nucleus ReadyStart V3", "version": { "version_data": [ { "version_value": "All versions \u003c V2017.02.4" } ] } }, { "product_name": "Nucleus ReadyStart V4", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.1" } ] } }, { "product_name": "Nucleus Source Code", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "PLUSCONTROL 1st Gen", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMOTICS CONNECT 400", "version": { "version_data": [ { "version_value": "All versions \u003c V0.5.0.0" } ] } }, { "product_name": "TALON TC Compact (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } }, { "product_name": "TALON TC Modular (BACnet)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.5.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-1284: Improper Validation of Specified Quantity in Input" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31346", "datePublished": "2021-11-09T11:31:53", "dateReserved": "2021-04-15T00:00:00", "dateUpdated": "2024-08-03T22:55:53.543Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }