icsa-22-104-08
Vulnerability from csaf_cisa
Published
2022-04-14 00:00
Modified
2022-04-14 00:00
Summary
Siemens SCALANCE W1700
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to cause various denial-of-service conditions.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Exploitability
No known public exploits specifically target these vulnerabilities.
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to cause various denial-of-service conditions.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-392912: Multiple Denial Of Service Vulnerabilities in SCALANCE W1700 Devices - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-392912.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-104-08 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-104-08.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-104-08 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-08" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-08" }, { "category": "external", "summary": "SSA-392912: Multiple Denial Of Service Vulnerabilities in SCALANCE W1700 Devices - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf" }, { "category": "external", "summary": "SSA-392912: Multiple Denial Of Service Vulnerabilities in SCALANCE W1700 Devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-392912.txt" } ], "title": "Siemens SCALANCE W1700", "tracking": { "current_release_date": "2022-04-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-104-08", "initial_release_date": "2022-04-14T00:00:00.000000Z", "revision_history": [ { "date": "2022-04-14T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-104-08 Siemens SCALANCE W1700" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V3.0.0", "product": { "name": "SCALANCE W1788-1 M12", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK5788-1GY01-0AA0" ] } } } ], "category": "product_name", "name": "SCALANCE W1788-1 M12" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.0.0", "product": { "name": "SCALANCE W1788-2 EEC M12", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK5788-2GY01-0TA0" ] } } } ], "category": "product_name", "name": "SCALANCE W1788-2 EEC M12" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.0.0", "product": { "name": "SCALANCE W1788-2 M12", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5788-2GY01-0AA0" ] } } } ], "category": "product_name", "name": "SCALANCE W1788-2 M12" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.0.0", "product": { "name": "SCALANCE W1788-2IA M12", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK5788-2HY01-0AA0" ] } } } ], "category": "product_name", "name": "SCALANCE W1788-2IA M12" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-27481", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly handle resources of ARP requests. This could allow an attacker to cause a race condition that leads to a crash of the entire device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2022-27481 - SCALANCE W1788-1 M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-27481 - SCALANCE W1788-2 EEC M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-27481 - SCALANCE W1788-2 M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-27481 - SCALANCE W1788-2IA M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-27481 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-27481.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-27481" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "category": "workaround", "details": "For CVE-2022-28329: Deactivate the RemoteCapture feature if not required. This feature is deactivated by default", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "workaround", "details": "For CVE-2022-28329: Restrict network access to the RemoteCapture feature to trusted communication partners", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2022-27481" }, { "cve": "CVE-2022-28328", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2022-28328 - SCALANCE W1788-1 M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-28328 - SCALANCE W1788-2 EEC M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-28328 - SCALANCE W1788-2 M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-28328 - SCALANCE W1788-2IA M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-28328 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-28328.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-28328" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "category": "workaround", "details": "For CVE-2022-28329: Deactivate the RemoteCapture feature if not required. This feature is deactivated by default", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "workaround", "details": "For CVE-2022-28329: Restrict network access to the RemoteCapture feature to trusted communication partners", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2022-28328" }, { "cve": "CVE-2022-28329", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "summary": "CVE-2022-28329 - SCALANCE W1788-1 M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-28329 - SCALANCE W1788-2 EEC M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-28329 - SCALANCE W1788-2 M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-28329 - SCALANCE W1788-2IA M12", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "summary": "CVE-2022-28329 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-28329.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-28329" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808629/" }, { "category": "workaround", "details": "For CVE-2022-28329: Deactivate the RemoteCapture feature if not required. This feature is deactivated by default", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "workaround", "details": "For CVE-2022-28329: Restrict network access to the RemoteCapture feature to trusted communication partners", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2022-28329" } ] }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.