CVE-2022-28329 (GCVE-0-2022-28329)
Vulnerability from cvelistv5 – Published: 2022-04-12 09:08 – Updated: 2024-08-03 05:48
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature.
Severity
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
4 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
All versions < V3.0.0
|
guessed | |
| Siemens | SCALANCE W1788-2 EEC M12 |
Affected:
All versions < V3.0.0
|
guessed | |
| Siemens | SCALANCE W1788-2 M12 |
Affected:
All versions < V3.0.0
|
guessed | |
| Siemens | SCALANCE W1788-2IA M12 |
Affected:
All versions < V3.0.0
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:38.032Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T09:08:07.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-28329",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE W1788-1 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 EEC M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2IA M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20: Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-28329",
"datePublished": "2022-04-12T09:08:07.000Z",
"dateReserved": "2022-04-01T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:48:38.032Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-28329",
"date": "2026-09-20",
"epss": "0.00369",
"percentile": "0.30699"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w1788-2ia_m12_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C2A7EE5C-4FF7-4B6C-AC85-0B992BBB237B",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w1788-2ia_m12:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D9491822-56EE-4065-B199-040BEE283ED0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w1788-2_m12_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "787289C3-1A38-4F3A-856F-5E79B150F14F",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w1788-2_m12:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D8AA449C-52AE-4286-8BD2-C1A54A1AC64E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w1788-2_eec_m12_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3D981998-87CF-4EF8-9430-F4ACF3214B58",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w1788-2_eec_m12:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8AE6F9AD-37DB-4067-8BB4-10CDD3AA8E23",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w1788-1_m12_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "32D25E1B-2C32-483C-B520-8AA7B02162F0",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w1788-1_m12:-:*:*:*:*:*:*:*",
"matchCriteriaId": "408600B8-762D-43C9-A259-7163FA9DB788",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SCALANCE W1788-1 M12 (todas las versiones anteriores a V3.0.0), SCALANCE W1788-2 EEC M12 (todas las versiones anteriores a V3.0.0), SCALANCE W1788-2 M12 (todas las versiones anteriores a V3.0.0), SCALANCE W1788-2IA M12 (todas las versiones anteriores a V3.0.0). Los dispositivos afectados no manejan correctamente los paquetes TCP malformados recibidos a trav\u00e9s de la funci\u00f3n RemoteCapture. Esto podr\u00eda permitir a un atacante conllevar a una condici\u00f3n de denegaci\u00f3n de servicio que s\u00f3lo afecta al puerto usado por la funci\u00f3n RemoteCapture"
}
],
"id": "CVE-2022-28329",
"lastModified": "2024-11-21T06:57:10.490",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-12T09:15:15.240",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
}
],
"source": "productcert@siemens.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w1788-2ia_m12_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C2A7EE5C-4FF7-4B6C-AC85-0B992BBB237B",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w1788-2ia_m12:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D9491822-56EE-4065-B199-040BEE283ED0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w1788-2_m12_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "787289C3-1A38-4F3A-856F-5E79B150F14F",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w1788-2_m12:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D8AA449C-52AE-4286-8BD2-C1A54A1AC64E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w1788-2_eec_m12_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3D981998-87CF-4EF8-9430-F4ACF3214B58",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w1788-2_eec_m12:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8AE6F9AD-37DB-4067-8BB4-10CDD3AA8E23",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w1788-1_m12_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "32D25E1B-2C32-483C-B520-8AA7B02162F0",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w1788-1_m12:-:*:*:*:*:*:*:*",
"matchCriteriaId": "408600B8-762D-43C9-A259-7163FA9DB788",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SCALANCE W1788-1 M12 (todas las versiones anteriores a V3.0.0), SCALANCE W1788-2 EEC M12 (todas las versiones anteriores a V3.0.0), SCALANCE W1788-2 M12 (todas las versiones anteriores a V3.0.0), SCALANCE W1788-2IA M12 (todas las versiones anteriores a V3.0.0). Los dispositivos afectados no manejan correctamente los paquetes TCP malformados recibidos a trav\u00e9s de la funci\u00f3n RemoteCapture. Esto podr\u00eda permitir a un atacante conllevar a una condici\u00f3n de denegaci\u00f3n de servicio que s\u00f3lo afecta al puerto usado por la funci\u00f3n RemoteCapture"
}
],
"id": "CVE-2022-28329",
"lastModified": "2026-06-17T04:38:23.900",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-12T09:15:15.240",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T12:33:18+00:00",
"cve": "CVE-2022-28329",
"id": "CVE-2022-28329",
"initial_release_date": "2022-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2022-28329",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-28329.json",
"version": "3"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…