icsa-24-074-05
Vulnerability from csaf_cisa
Published
2024-03-12 00:00
Modified
2024-03-12 00:00
Summary
Siemens RUGGEDCOM APE1808
Notes
Summary
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products.
Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet's upstream security notifications.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products.\nSiemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet\u0027s upstream security notifications.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 devices - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-832273.json" }, { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 devices - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-832273.html" }, { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 devices - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-832273.pdf" }, { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-832273.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-074-05 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-074-05.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-074-05 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-05" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens RUGGEDCOM APE1808", "tracking": { "current_release_date": "2024-03-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-074-05", "initial_release_date": "2024-03-12T00:00:00.000000Z", "revision_history": [ { "date": "2024-03-12T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions with Fortinet NGFW", "product": { "name": "RUGGEDCOM APE1808", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "RUGGEDCOM APE1808" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-38545", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A heap-based buffer overflow vulnerability in the SOCKS5 proxy handshake in the Curl package. If Curl is unable to resolve the address itself, it passes the hostname to the SOCKS5 proxy. However, the maximum length of the hostname that can be passed is 255 bytes. If the hostname is longer, then Curl switches to the local name resolving and passes the resolved address only to the proxy. The local variable that instructs Curl to \"let the host resolve the name\" could obtain the wrong value during a slow SOCKS5 handshake, resulting in the too-long hostname being copied to the target buffer instead of the resolved address, which was not the intended behavior.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-38545" }, { "cve": "CVE-2023-38546", "cwe": { "id": "CWE-73", "name": "External Control of File Name or Path" }, "notes": [ { "category": "summary", "text": "This flaw allows an attacker to insert cookies at will into a running program\r\nusing libcurl, if the specific series of conditions are met.\r\n\r\nlibcurl performs transfers. In its API, an application creates \"easy handles\"\r\nthat are the individual handles for single transfers.\r\n\r\nlibcurl provides a function call that duplicates en easy handle called\r\n[curl_easy_duphandle](https://curl.se/libcurl/c/curl_easy_duphandle.html).\r\n\r\nIf a transfer has cookies enabled when the handle is duplicated, the\r\ncookie-enable state is also cloned - but without cloning the actual\r\ncookies. If the source handle did not read any cookies from a specific file on\r\ndisk, the cloned version of the handle would instead store the file name as\r\n`none` (using the four ASCII letters, no quotes).\r\n\r\nSubsequent use of the cloned handle that does not explicitly set a source to\r\nload cookies from would then inadvertently load cookies from a file named\r\n`none` - if such a file exists and is readable in the current directory of the\r\nprogram using libcurl. And if using the correct file format of course.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-38546" }, { "cve": "CVE-2023-44250", "cwe": { "id": "CWE-269", "name": "Improper Privilege Management" }, "notes": [ { "category": "summary", "text": "An improper privilege management vulnerability [CWE-269] in a Fortinet FortiOS HA cluster version 7.4.0 through 7.4.1 and 7.2.5 and in a FortiProxy HA cluster version 7.4.0 through 7.4.1 allows an authenticated attacker to perform elevated actions via crafted HTTP or HTTPS requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-44250" }, { "cve": "CVE-2023-44487", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-44487" }, { "cve": "CVE-2023-47537", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 and 7.4.0 - 7.4.1 allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-47537" }, { "cve": "CVE-2024-21762", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A out-of-bounds write in Fortinet FortiOS versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.6, 7.0.0 through 7.0.13, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, 6.0.0 through 6.0.17, FortiProxy versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.8, 7.0.0 through 7.0.14, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7 allows attacker to execute unauthorized code or commands via specifically crafted requests", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Disable SSL VPN (disable webmode is NOT a valid workaround) (see \nhttps://www.fortiguard.com/psirt/FG-IR-24-015)", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-21762" }, { "cve": "CVE-2024-23113", "cwe": { "id": "CWE-134", "name": "Use of Externally-Controlled Format String" }, "notes": [ { "category": "summary", "text": "A use of externally-controlled format string vulnerability [CWE-134] in FortiOS fgfmd daemon may allow a remote unauthenticated attacker to execute arbitrary code or commands via specially crafted requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "For each interface, remove the fgfm access (see \nhttps://www.fortiguard.com/psirt/FG-IR-24-029)", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-23113" } ] }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.