Action not permitted
Modal body text goes here.
cve-2023-47537
Vulnerability from cvelistv5
Published
2024-02-15 13:59
Modified
2024-08-02 21:09
Severity ?
EPSS score ?
Summary
An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6, 7.4.0 - 7.4.1 and 6.4 all versions allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch.
References
▼ | URL | Tags | |
---|---|---|---|
psirt@fortinet.com | https://fortiguard.com/psirt/FG-IR-23-301 | Vendor Advisory |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fortios", "vendor": "fortinet", "versions": [ { "status": "affected", "version": "6.4.0" }, { "status": "affected", "version": "7.0.0" }, { "status": "affected", "version": "7.2.0" }, { "status": "affected", "version": "7.4.0" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-47537", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-21T13:43:02.127242Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:26:31.940Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T21:09:37.377Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://fortiguard.com/psirt/FG-IR-23-301", "tags": [ "x_transferred" ], "url": "https://fortiguard.com/psirt/FG-IR-23-301" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FortiOS", "vendor": "Fortinet", "versions": [ { "lessThanOrEqual": "7.4.1", "status": "affected", "version": "7.4.0", "versionType": "semver" }, { "lessThanOrEqual": "7.2.6", "status": "affected", "version": "7.2.0", "versionType": "semver" }, { "lessThanOrEqual": "7.0.15", "status": "affected", "version": "7.0.0", "versionType": "semver" }, { "lessThanOrEqual": "6.4.15", "status": "affected", "version": "6.4.0", "versionType": "semver" } ] } ], "descriptions": [ { "lang": "en", "value": "An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6, 7.4.0 - 7.4.1 and 6.4 all versions allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N/E:U/RL:X/RC:X", "version": "3.1" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-295", "description": "Information disclosure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-21T10:01:53.833Z", "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8", "shortName": "fortinet" }, "references": [ { "name": "https://fortiguard.com/psirt/FG-IR-23-301", "url": "https://fortiguard.com/psirt/FG-IR-23-301" } ], "solutions": [ { "lang": "en", "value": "Please upgrade to FortiOS version 7.4.2 or above \nPlease upgrade to FortiOS version 7.2.7 or above \nPlease upgrade to FortiOS version 7.0.16 or above \n" } ] } }, "cveMetadata": { "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8", "assignerShortName": "fortinet", "cveId": "CVE-2023-47537", "datePublished": "2024-02-15T13:59:24.770Z", "dateReserved": "2023-11-06T10:35:25.828Z", "dateUpdated": "2024-08-02T21:09:37.377Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-47537\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2024-02-15T14:15:45.240\",\"lastModified\":\"2024-05-21T10:15:09.910\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6, 7.4.0 - 7.4.1 and 6.4 all versions allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de validaci\u00f3n de certificado incorrecta en Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 y 7.4.0 - 7.4.1 permite que un atacante remoto y no autenticado realice un ataque Man-in-the-Middle en el Canal de comunicaci\u00f3n FortiLink entre el dispositivo FortiOS y FortiSwitch.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.2,\"impactScore\":2.5},{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.2,\"impactScore\":2.5}]},\"weaknesses\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-295\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0.0\",\"versionEndExcluding\":\"7.0.14\",\"matchCriteriaId\":\"C119229A-3805-47C1-B3F9-AF1A4007A63B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.2.0\",\"versionEndIncluding\":\"7.2.6\",\"matchCriteriaId\":\"24D09A92-81EC-4003-B017-C67FC739EEBF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:7.4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"61540F5B-080A-4D44-8BE0-75D7A0DCCB53\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:7.4.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17FE168A-0EA4-467C-91D2-87EB6D83917A\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.com/psirt/FG-IR-23-301\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
ghsa-37rj-769r-rwrv
Vulnerability from github
Published
2024-02-15 15:30
Modified
2024-02-15 15:30
Severity ?
Details
An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 and 7.4.0 - 7.4.1 allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch.
{ "affected": [], "aliases": [ "CVE-2023-47537" ], "database_specific": { "cwe_ids": [ "CWE-295" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2024-02-15T14:15:45Z", "severity": "MODERATE" }, "details": "An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 and 7.4.0 - 7.4.1 allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch.", "id": "GHSA-37rj-769r-rwrv", "modified": "2024-02-15T15:30:29Z", "published": "2024-02-15T15:30:29Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-47537" }, { "type": "WEB", "url": "https://fortiguard.com/psirt/FG-IR-23-301" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "type": "CVSS_V3" } ] }
gsd-2023-47537
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 and 7.4.0 - 7.4.1 allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-47537", "id": "GSD-2023-47537" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-47537" ], "details": "An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 and 7.4.0 - 7.4.1 allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch.", "id": "GSD-2023-47537", "modified": "2023-12-13T01:20:51.832845Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@fortinet.com", "ID": "CVE-2023-47537", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "FortiOS", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "7.4.0", "version_value": "7.4.1" }, { "version_affected": "\u003c=", "version_name": "7.2.0", "version_value": "7.2.6" }, { "version_affected": "\u003c=", "version_name": "7.0.0", "version_value": "7.0.14" } ] } } ] }, "vendor_name": "Fortinet" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 and 7.4.0 - 7.4.1 allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch." } ] }, "impact": { "cvss": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N/E:U/RL:X/RC:X", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-295", "lang": "eng", "value": "Information disclosure" } ] } ] }, "references": { "reference_data": [ { "name": "https://fortiguard.com/psirt/FG-IR-23-301", "refsource": "MISC", "url": "https://fortiguard.com/psirt/FG-IR-23-301" } ] }, "solution": [ { "lang": "en", "value": "Please upgrade to FortiOS version 7.4.2 or above \nPlease upgrade to FortiOS version 7.2.7 or above \n" } ] }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*", "matchCriteriaId": "C119229A-3805-47C1-B3F9-AF1A4007A63B", "versionEndExcluding": "7.0.14", "versionStartIncluding": "7.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*", "matchCriteriaId": "24D09A92-81EC-4003-B017-C67FC739EEBF", "versionEndIncluding": "7.2.6", "versionStartIncluding": "7.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:fortinet:fortios:7.4.0:*:*:*:*:*:*:*", "matchCriteriaId": "61540F5B-080A-4D44-8BE0-75D7A0DCCB53", "vulnerable": true }, { "criteria": "cpe:2.3:o:fortinet:fortios:7.4.1:*:*:*:*:*:*:*", "matchCriteriaId": "17FE168A-0EA4-467C-91D2-87EB6D83917A", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "descriptions": [ { "lang": "en", "value": "An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 and 7.4.0 - 7.4.1 allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch." }, { "lang": "es", "value": "Una vulnerabilidad de validaci\u00f3n de certificado incorrecta en Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 y 7.4.0 - 7.4.1 permite que un atacante remoto y no autenticado realice un ataque Man-in-the-Middle en el Canal de comunicaci\u00f3n FortiLink entre el dispositivo FortiOS y FortiSwitch." } ], "id": "CVE-2023-47537", "lastModified": "2024-02-22T15:26:01.937", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 2.5, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 2.5, "source": "psirt@fortinet.com", "type": "Secondary" } ] }, "published": "2024-02-15T14:15:45.240", "references": [ { "source": "psirt@fortinet.com", "tags": [ "Vendor Advisory" ], "url": "https://fortiguard.com/psirt/FG-IR-23-301" } ], "sourceIdentifier": "psirt@fortinet.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-295" } ], "source": "psirt@fortinet.com", "type": "Primary" } ] } } } }
ssa-832273
Vulnerability from csaf_siemens
Published
2024-03-12 00:00
Modified
2024-06-11 00:00
Summary
SSA-832273: Multiple Vulnerabilities in Fortigate NGFW before V7.4.3 on RUGGEDCOM APE1808 devices
Notes
Summary
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products.
Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet's upstream security notifications.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products.\nSiemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet\u0027s upstream security notifications.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW before V7.4.3 on RUGGEDCOM APE1808 devices - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-832273.html" }, { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW before V7.4.3 on RUGGEDCOM APE1808 devices - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-832273.json" }, { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW before V7.4.3 on RUGGEDCOM APE1808 devices - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-832273.pdf" }, { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW before V7.4.3 on RUGGEDCOM APE1808 devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-832273.txt" } ], "title": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW before V7.4.3 on RUGGEDCOM APE1808 devices", "tracking": { "current_release_date": "2024-06-11T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-832273", "initial_release_date": "2024-03-12T00:00:00Z", "revision_history": [ { "date": "2024-03-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-04-09T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added CVE-2023-42789, CVE-2023-42790, CVE-2023-46717, CVE-2024-23112 and updated remediations" }, { "date": "2024-05-14T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added CVE-2024-23662, CVE-2023-48784, CVE-2023-41677. Adapted title to reflect latest Siemens validated release version of Fortinet NGFW" }, { "date": "2024-06-11T00:00:00Z", "legacy_version": "1.3", "number": "4", "summary": "Added newly published upstream CVEs CVE-2023-45586, CVE-2024-26007, CVE-2023-36640, CVE-2023-45583, CVE-2023-44247, CVE-2023-46714" } ], "status": "final", "version": "4" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions with Fortinet NGFW \u003c V7.4.3", "product": { "name": "RUGGEDCOM APE1808", "product_id": "1" } }, { "category": "product_version_range", "name": "All versions with Fortinet NGFW \u003c V7.4.3 and captive portal enabled", "product": { "name": "RUGGEDCOM APE1808", "product_id": "2" } } ], "category": "product_name", "name": "RUGGEDCOM APE1808" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-36640", "cwe": { "id": "CWE-134", "name": "Use of Externally-Controlled Format String" }, "notes": [ { "category": "summary", "text": "A use of externally-controlled format string in Fortinet FortiProxy versions 7.2.0 through 7.2.4, 7.0.0 through 7.0.10, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, FortiPAM versions 1.0.0 through 1.0.3, FortiOS versions 7.2.0, 7.0.0 through 7.0.12, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, 6.0.0 through 6.0.16 allows attacker to execute unauthorized code or commands via specially crafted commands", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-36640" }, { "cve": "CVE-2023-38545", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A heap-based buffer overflow vulnerability in the SOCKS5 proxy handshake in the Curl package. If Curl is unable to resolve the address itself, it passes the hostname to the SOCKS5 proxy. However, the maximum length of the hostname that can be passed is 255 bytes. If the hostname is longer, then Curl switches to the local name resolving and passes the resolved address only to the proxy. The local variable that instructs Curl to \"let the host resolve the name\" could obtain the wrong value during a slow SOCKS5 handshake, resulting in the too-long hostname being copied to the target buffer instead of the resolved address, which was not the intended behavior.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-38545" }, { "cve": "CVE-2023-38546", "cwe": { "id": "CWE-73", "name": "External Control of File Name or Path" }, "notes": [ { "category": "summary", "text": "This flaw allows an attacker to insert cookies at will into a running program\r\nusing libcurl, if the specific series of conditions are met.\r\n\r\nlibcurl performs transfers. In its API, an application creates \"easy handles\"\r\nthat are the individual handles for single transfers.\r\n\r\nlibcurl provides a function call that duplicates en easy handle called\r\n[curl_easy_duphandle](https://curl.se/libcurl/c/curl_easy_duphandle.html).\r\n\r\nIf a transfer has cookies enabled when the handle is duplicated, the\r\ncookie-enable state is also cloned - but without cloning the actual\r\ncookies. If the source handle did not read any cookies from a specific file on\r\ndisk, the cloned version of the handle would instead store the file name as\r\n`none` (using the four ASCII letters, no quotes).\r\n\r\nSubsequent use of the cloned handle that does not explicitly set a source to\r\nload cookies from would then inadvertently load cookies from a file named\r\n`none` - if such a file exists and is readable in the current directory of the\r\nprogram using libcurl. And if using the correct file format of course.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-38546" }, { "cve": "CVE-2023-41677", "cwe": { "id": "CWE-522", "name": "Insufficiently Protected Credentials" }, "notes": [ { "category": "summary", "text": "A insufficiently protected credentials in Fortinet FortiProxy 7.4.0, 7.2.0 through 7.2.6, 7.0.0 through 7.0.12, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, Fortinet FortiOS 7.4.0 through 7.4.1, 7.2.0 through 7.2.6, 7.0.0 through 7.0.12, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, 6.0.0 through 6.0.17 allows attacker to execute unauthorized code or commands via targeted social engineering attack", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-41677" }, { "cve": "CVE-2023-42789", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A out-of-bounds write in Fortinet FortiOS 7.4.0 through 7.4.1, 7.2.0 through 7.2.5, 7.0.0 through 7.0.12, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, FortiProxy 7.4.0, 7.2.0 through 7.2.6, 7.0.0 through 7.0.12, 2.0.0 through 2.0.13 allows attacker to execute unauthorized code or commands via specially crafted HTTP requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "2" ] }, "remediations": [ { "category": "mitigation", "details": "Set a non form-based authentication scheme (see \nhttps://fortiguard.fortinet.com/psirt/FG-IR-23-328)", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "2" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2" ] } ], "title": "CVE-2023-42789" }, { "cve": "CVE-2023-42790", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A stack-based buffer overflow in Fortinet FortiOS 7.4.0 through 7.4.1, 7.2.0 through 7.2.5, 7.0.0 through 7.0.12, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, FortiProxy 7.4.0, 7.2.0 through 7.2.6, 7.0.0 through 7.0.12, 2.0.0 through 2.0.13 allows attacker to execute unauthorized code or commands via specially crafted HTTP requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "2" ] }, "remediations": [ { "category": "mitigation", "details": "Set a non form-based authentication scheme (see \nhttps://fortiguard.fortinet.com/psirt/FG-IR-23-328)", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "2" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2" ] } ], "title": "CVE-2023-42790" }, { "cve": "CVE-2023-44247", "cwe": { "id": "CWE-415", "name": "Double Free" }, "notes": [ { "category": "summary", "text": "A double free vulnerability [CWE-415] in Fortinet FortiOS before 7.0.0 may allow a privileged attacker to execute code or commands via crafted HTTP or HTTPs requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-44247" }, { "cve": "CVE-2023-44250", "cwe": { "id": "CWE-269", "name": "Improper Privilege Management" }, "notes": [ { "category": "summary", "text": "An improper privilege management vulnerability [CWE-269] in a Fortinet FortiOS HA cluster version 7.4.0 through 7.4.1 and 7.2.5 and in a FortiProxy HA cluster version 7.4.0 through 7.4.1 allows an authenticated attacker to perform elevated actions via crafted HTTP or HTTPS requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-44250" }, { "cve": "CVE-2023-44487", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-44487" }, { "cve": "CVE-2023-45583", "cwe": { "id": "CWE-134", "name": "Use of Externally-Controlled Format String" }, "notes": [ { "category": "summary", "text": "A use of externally-controlled format string in Fortinet FortiProxy versions 7.2.0 through 7.2.5, 7.0.0 through 7.0.11, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6 FortiPAM versions 1.1.0, 1.0.0 through 1.0.3 FortiOS versions 7.4.0, 7.2.0 through 7.2.5, 7.0.0 through 7.0.13, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15 FortiSwitchManager versions 7.2.0 through 7.2.2, 7.0.0 through 7.0.2 allows attacker to execute unauthorized code or commands via specially crafted cli commands and http requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-45583" }, { "cve": "CVE-2023-45586", "cwe": { "id": "CWE-345", "name": "Insufficient Verification of Data Authenticity" }, "notes": [ { "category": "summary", "text": "An insufficient verification of data authenticity vulnerability [CWE-345] in FortiOS \u0026 FortiProxy SSL-VPN tunnel mode may allow an authenticated VPN user to send (but not receive) packets spoofing the IP of another user via crafted network packets.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-45586" }, { "cve": "CVE-2023-46714", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A stack-based buffer overflow [CWE-121] vulnerability in Fortinet FortiOS version 7.2.1 through 7.2.6 and version 7.4.0 through 7.4.1 allows a privileged attacker over the administrative interface to execute arbitrary code or commands via crafted HTTP or HTTPs requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-46714" }, { "cve": "CVE-2023-46717", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "An improper authentication vulnerability [CWE-287] in FortiOS versions 7.4.1 and below, versions 7.2.6 and below, and versions 7.0.12 and below when configured with FortiAuthenticator in HA may allow a readonly user to gain read-write access via successive login attempts.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-46717" }, { "cve": "CVE-2023-47537", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 and 7.4.0 - 7.4.1 allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-47537" }, { "cve": "CVE-2023-48784", "cwe": { "id": "CWE-134", "name": "Use of Externally-Controlled Format String" }, "notes": [ { "category": "summary", "text": "A\u00a0use of externally-controlled format string vulnerability [CWE-134] in FortiOS version 7.4.1 and below, version 7.2.7 and below, version 7.0.14 and below, version 6.4.15 and below command line interface may allow a local\u00a0privileged attacker with super-admin profile and CLI access\u00a0to execute arbitrary code or commands via specially crafted requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RC:R", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48784" }, { "cve": "CVE-2024-21762", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A out-of-bounds write in Fortinet FortiOS versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.6, 7.0.0 through 7.0.13, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, 6.0.0 through 6.0.17, FortiProxy versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.8, 7.0.0 through 7.0.14, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7 allows attacker to execute unauthorized code or commands via specifically crafted requests", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "Disable SSL VPN (disable webmode is NOT a valid workaround) (see \nhttps://www.fortiguard.com/psirt/FG-IR-24-015)", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-21762" }, { "cve": "CVE-2024-23112", "cwe": { "id": "CWE-639", "name": "Authorization Bypass Through User-Controlled Key" }, "notes": [ { "category": "summary", "text": "An authorization bypass through user-controlled key vulnerability [CWE-639] in FortiOS version 7.4.0 through 7.4.1, 7.2.0 through 7.2.6, 7.0.1 through 7.0.13, 6.4.7 through 6.4.14, and FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.8, 7.0.0 through 7.0.14 SSL-VPN may allow an authenticated attacker to gain access to another user\u2019s bookmark via URL manipulation.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-23112" }, { "cve": "CVE-2024-23113", "cwe": { "id": "CWE-134", "name": "Use of Externally-Controlled Format String" }, "notes": [ { "category": "summary", "text": "A use of externally-controlled format string vulnerability [CWE-134] in FortiOS fgfmd daemon may allow a remote unauthenticated attacker to execute arbitrary code or commands via specially crafted requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "For each interface, remove the fgfm access (see \nhttps://www.fortiguard.com/psirt/FG-IR-24-029)", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-23113" }, { "cve": "CVE-2024-23662", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "An exposure of sensitive information to an unauthorized actor in Fortinet FortiOS at least version at least 7.4.0 through 7.4.1 and 7.2.0 through 7.2.5 and 7.0.0 through 7.0.15 and 6.4.0 through 6.4.15 allows attacker to information disclosure via HTTP requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-23662" }, { "cve": "CVE-2024-26007", "cwe": { "id": "CWE-703", "name": "Improper Check or Handling of Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "An improper check or handling of exceptional conditions vulnerability [CWE-703] in Fortinet FortiOS version 7.4.1 allows an unauthenticated attacker to provoke a denial of service on the administrative interface via crafted HTTP requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-26007" } ] }
wid-sec-w-2024-0343
Vulnerability from csaf_certbund
Published
2024-02-11 23:00
Modified
2024-02-11 23:00
Summary
Fortinet FortiOS: Schwachstelle ermöglicht Offenlegung von Informationen
Notes
Das BSI ist als Anbieter für die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch dafür verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgfältig im Einzelfall zu prüfen.
Produktbeschreibung
FortiOS ist ein gehärtetes Betriebssystem für FortiGate Plattformen.
Angriff
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Fortinet FortiOS ausnutzen, um Informationen offenzulegen.
Betroffene Betriebssysteme
- Sonstiges
{ "document": { "aggregate_severity": { "text": "mittel" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "FortiOS ist ein geh\u00e4rtetes Betriebssystem f\u00fcr FortiGate Plattformen.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Fortinet FortiOS ausnutzen, um Informationen offenzulegen.", "title": "Angriff" }, { "category": "general", "text": "- Sonstiges", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2024-0343 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2024/wid-sec-w-2024-0343.json" }, { "category": "self", "summary": "WID-SEC-2024-0343 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2024-0343" }, { "category": "external", "summary": "FortiGuard PSIRT Advisory vom 2024-02-11", "url": "https://www.fortiguard.com/psirt/FG-IR-23-301" } ], "source_lang": "en-US", "title": "Fortinet FortiOS: Schwachstelle erm\u00f6glicht Offenlegung von Informationen", "tracking": { "current_release_date": "2024-02-11T23:00:00.000+00:00", "generator": { "date": "2024-02-15T17:59:51.037+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2024-0343", "initial_release_date": "2024-02-11T23:00:00.000+00:00", "revision_history": [ { "date": "2024-02-11T23:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 7.4.2", "product": { "name": "Fortinet FortiOS \u003c 7.4.2", "product_id": "T032665", "product_identification_helper": { "cpe": "cpe:/o:fortinet:fortios:7.4.2" } } }, { "category": "product_version_range", "name": "\u003c 7.2.7", "product": { "name": "Fortinet FortiOS \u003c 7.2.7", "product_id": "T032666", "product_identification_helper": { "cpe": "cpe:/o:fortinet:fortios:7.2.7" } } } ], "category": "product_name", "name": "FortiOS" } ], "category": "vendor", "name": "Fortinet" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-47537", "notes": [ { "category": "description", "text": "Es besteht eine Schwachstelle in Fortinet FortiOS. Dieser Fehler besteht aufgrund einer unsachgem\u00e4\u00dfen Zertifikatsvalidierung, die es erm\u00f6glicht, den FortiLink-Kommunikationskanal zwischen dem FortiOS-Ger\u00e4t und einer FortiSwitch-Instanz von einer Man-in-the-Middle-Position aus zu entschl\u00fcsseln und zu ver\u00e4ndern. Ein entfernter, anonymer Angreifer kann diese Schwachstelle ausnutzen, um vertrauliche Informationen offenzulegen." } ], "release_date": "2024-02-11T23:00:00Z", "title": "CVE-2023-47537" } ] }
icsa-24-074-05
Vulnerability from csaf_cisa
Published
2024-03-12 00:00
Modified
2024-03-12 00:00
Summary
Siemens RUGGEDCOM APE1808
Notes
Summary
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products.
Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet's upstream security notifications.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products.\nSiemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet\u0027s upstream security notifications.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 devices - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-832273.json" }, { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 devices - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-832273.html" }, { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 devices - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-832273.pdf" }, { "category": "self", "summary": "SSA-832273: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-832273.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-074-05 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-074-05.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-074-05 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-05" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens RUGGEDCOM APE1808", "tracking": { "current_release_date": "2024-03-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-074-05", "initial_release_date": "2024-03-12T00:00:00.000000Z", "revision_history": [ { "date": "2024-03-12T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions with Fortinet NGFW", "product": { "name": "RUGGEDCOM APE1808", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "RUGGEDCOM APE1808" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-38545", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A heap-based buffer overflow vulnerability in the SOCKS5 proxy handshake in the Curl package. If Curl is unable to resolve the address itself, it passes the hostname to the SOCKS5 proxy. However, the maximum length of the hostname that can be passed is 255 bytes. If the hostname is longer, then Curl switches to the local name resolving and passes the resolved address only to the proxy. The local variable that instructs Curl to \"let the host resolve the name\" could obtain the wrong value during a slow SOCKS5 handshake, resulting in the too-long hostname being copied to the target buffer instead of the resolved address, which was not the intended behavior.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-38545" }, { "cve": "CVE-2023-38546", "cwe": { "id": "CWE-73", "name": "External Control of File Name or Path" }, "notes": [ { "category": "summary", "text": "This flaw allows an attacker to insert cookies at will into a running program\r\nusing libcurl, if the specific series of conditions are met.\r\n\r\nlibcurl performs transfers. In its API, an application creates \"easy handles\"\r\nthat are the individual handles for single transfers.\r\n\r\nlibcurl provides a function call that duplicates en easy handle called\r\n[curl_easy_duphandle](https://curl.se/libcurl/c/curl_easy_duphandle.html).\r\n\r\nIf a transfer has cookies enabled when the handle is duplicated, the\r\ncookie-enable state is also cloned - but without cloning the actual\r\ncookies. If the source handle did not read any cookies from a specific file on\r\ndisk, the cloned version of the handle would instead store the file name as\r\n`none` (using the four ASCII letters, no quotes).\r\n\r\nSubsequent use of the cloned handle that does not explicitly set a source to\r\nload cookies from would then inadvertently load cookies from a file named\r\n`none` - if such a file exists and is readable in the current directory of the\r\nprogram using libcurl. And if using the correct file format of course.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-38546" }, { "cve": "CVE-2023-44250", "cwe": { "id": "CWE-269", "name": "Improper Privilege Management" }, "notes": [ { "category": "summary", "text": "An improper privilege management vulnerability [CWE-269] in a Fortinet FortiOS HA cluster version 7.4.0 through 7.4.1 and 7.2.5 and in a FortiProxy HA cluster version 7.4.0 through 7.4.1 allows an authenticated attacker to perform elevated actions via crafted HTTP or HTTPS requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-44250" }, { "cve": "CVE-2023-44487", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-44487" }, { "cve": "CVE-2023-47537", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 and 7.4.0 - 7.4.1 allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-47537" }, { "cve": "CVE-2024-21762", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A out-of-bounds write in Fortinet FortiOS versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.6, 7.0.0 through 7.0.13, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, 6.0.0 through 6.0.17, FortiProxy versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.8, 7.0.0 through 7.0.14, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7 allows attacker to execute unauthorized code or commands via specifically crafted requests", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Disable SSL VPN (disable webmode is NOT a valid workaround) (see \nhttps://www.fortiguard.com/psirt/FG-IR-24-015)", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-21762" }, { "cve": "CVE-2024-23113", "cwe": { "id": "CWE-134", "name": "Use of Externally-Controlled Format String" }, "notes": [ { "category": "summary", "text": "A use of externally-controlled format string vulnerability [CWE-134] in FortiOS fgfmd daemon may allow a remote unauthenticated attacker to execute arbitrary code or commands via specially crafted requests.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "For each interface, remove the fgfm access (see \nhttps://www.fortiguard.com/psirt/FG-IR-24-029)", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Contact customer support to receive patch and update information.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-23113" } ] }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.