Summary
B&R Automation Runtime Improper Handling of Flooding conditions on ANSL Server
Notes
Summary
ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that resolves a vulnerability.
An attacker who successfully exploited this vulnerability could cause the product to stop.
Support
For additional instructions and support please contact your local B&R service organization. For contact information, see https://www.br-automation.com/en/about-us/locations/.
Information about ABB’s cyber security program and capabilities can be found at www.abb.com/cybersecurity.
Notice
The information in this document is subject to change without notice, and should not be construed as a commitment by B&R.
B&R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&R or any of its suppliers be liable for direct, indirect, special, incidental or conse-quential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&R or its suppliers have been advised of the possibility of such damages.
This document and parts hereof must not be reproduced or copied without written permission from B&R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose.
All rights to registrations and trademarks reside with their respective owners.
General security recommendations
For any installation of software related ABB products we strongly recommend the following (non-exhaustive) list of cyber security practices:
– Isolate special purpose networks (e.g. for automation systems) and remote devices behind firewalls
and separate them from any general-purpose network (e.g. office or home networks).
– Install physical controls so no unauthorized personnel can access your devices, components, peripheral equipment, and networks.
– Never connect programming software or computers containing programing software to any network other than the network for the devices that it is intended for.
– Scan all data imported into your environment before use to detect potential malware infections.
– Minimize network exposure for all applications and endpoints to ensure that they are not accessible
from the Internet unless they are designed for such exposure and the intended use requires such.
– Ensure all nodes are always up to date in terms of installed software, operating system, and firmware
patches as well as anti-virus and firewall.
– When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.
More information on recommended practices can be found in the following documents:
- Defense in Depth for B&R products : https://www.br-automation.com/fileadmin/Cyber_Security_-_Defense_in_Depth_for_BR_Products-bdd37e82.pdf
Purpose
B&R has a rigorous internal cyber security continuous improvement process which involves regular testing with industry leading tools and periodic assessments to identify potential product issues. Occasionally an issue is determined to be a design or coding flaw with implications that may impact product cyber security.
When a potential product vulnerability is identified or reported, B&R immediately initiates our vulnerability handling process. This entails validating if the issue is in fact a product issue, identifying root causes, determining what related products may be impacted, developing a remediation, and notifying end users and governmental organizations.
The resulting Cyber Security Advisory intends to notify customers of the vulnerability and provide details on which products are impacted, how to mitigate the vulnerability or explain workarounds that minimize the potential risk as much as possible. The release of a Cyber Security Advisory should not be misconstrued as an affirmation or indication of an active threat or ongoing campaign targeting the products mentioned here. If B&R is aware of any specific threats, it will be clearly mentioned in the communication.
The publication of this Cyber Security Advisory is an example of B&R’s commitment to the user community in support of this critical topic. Responsible disclosure is an important element in the chain of trust we work to maintain with our many customers. The release of an Advisory provides timely information which is essential to help ensure our customers are fully informed.
Frequently Asked Questions
What causes the vulnerability?
- The vulnerability is caused by insufficient throttling and limiting mechanism in the ANSL Server used the B&R Automation Runtime.
What might an attacker use the vulnerability to do?
- An attacker who successfully exploited this vulnerability could cause the affected system node to stop.
How could an attacker exploit the vulnerability?
- An attacker could try to exploit the vulnerability by creating a specially crafted message and sending the message to an affected system node. This would require that the attacker has access to the system network, by connecting to the net-work either directly or through a wrongly configured or penetrated firewall, or that he installs malicious software on a system node or otherwise infects the network with malicious software. Recommended practices help mitigate such attacks, see section Mitigating Factors above.
Could the vulnerability be exploited remotely?
- Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed.
What does the update do?
- The update removes the vulnerability by limiting incoming network traffic that is handled by the ANSL server component.
When this security advisory was issued, had this vulnerability been publicly disclosed?
- No, B&R discovered this vulnerability as a part of its own security analysis.
When this security advisory was issued, had B&R received any reports that this vulnerability was being exploited?
- No, B&R had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that resolves a vulnerability.\n\nAn attacker who successfully exploited this vulnerability could cause the product to stop.",
"title": "Summary"
},
{
"category": "other",
"text": "For additional instructions and support please contact your local B\u0026R service organization. For contact information, see https://www.br-automation.com/en/about-us/locations/.\n\nInformation about ABB\u2019s cyber security program and capabilities can be found at www.abb.com/cybersecurity.\n\n",
"title": "Support"
},
{
"category": "legal_disclaimer",
"text": "The information in this document is subject to change without notice, and should not be construed as a commitment by B\u0026R.\n\nB\u0026R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B\u0026R or any of its suppliers be liable for direct, indirect, special, incidental or conse-quential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B\u0026R or its suppliers have been advised of the possibility of such damages.\n\nThis document and parts hereof must not be reproduced or copied without written permission from B\u0026R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose.\n\nAll rights to registrations and trademarks reside with their respective owners.",
"title": "Notice"
},
{
"category": "other",
"text": "For any installation of software related ABB products we strongly recommend the following (non-exhaustive) list of cyber security practices:\n\n\u2013 Isolate special purpose networks (e.g. for automation systems) and remote devices behind firewalls\nand separate them from any general-purpose network (e.g. office or home networks).\n\n\u2013 Install physical controls so no unauthorized personnel can access your devices, components, peripheral equipment, and networks.\n\n\u2013 Never connect programming software or computers containing programing software to any network other than the network for the devices that it is intended for.\n\n\u2013 Scan all data imported into your environment before use to detect potential malware infections.\n\n\u2013 Minimize network exposure for all applications and endpoints to ensure that they are not accessible\nfrom the Internet unless they are designed for such exposure and the intended use requires such.\n\n\u2013 Ensure all nodes are always up to date in terms of installed software, operating system, and firmware\npatches as well as anti-virus and firewall.\n\n\u2013 When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n\nMore information on recommended practices can be found in the following documents:\n- Defense in Depth for B\u0026R products : https://www.br-automation.com/fileadmin/Cyber_Security_-_Defense_in_Depth_for_BR_Products-bdd37e82.pdf",
"title": "General security recommendations"
},
{
"category": "other",
"text": "B\u0026R has a rigorous internal cyber security continuous improvement process which involves regular testing with industry leading tools and periodic assessments to identify potential product issues. Occasionally an issue is determined to be a design or coding flaw with implications that may impact product cyber security.\n\nWhen a potential product vulnerability is identified or reported, B\u0026R immediately initiates our vulnerability handling process. This entails validating if the issue is in fact a product issue, identifying root causes, determining what related products may be impacted, developing a remediation, and notifying end users and governmental organizations.\n\nThe resulting Cyber Security Advisory intends to notify customers of the vulnerability and provide details on which products are impacted, how to mitigate the vulnerability or explain workarounds that minimize the potential risk as much as possible. The release of a Cyber Security Advisory should not be misconstrued as an affirmation or indication of an active threat or ongoing campaign targeting the products mentioned here. If B\u0026R is aware of any specific threats, it will be clearly mentioned in the communication.\n\nThe publication of this Cyber Security Advisory is an example of B\u0026R\u2019s commitment to the user community in support of this critical topic. Responsible disclosure is an important element in the chain of trust we work to maintain with our many customers. The release of an Advisory provides timely information which is essential to help ensure our customers are fully informed.",
"title": "Purpose"
},
{
"category": "faq",
"text": "What causes the vulnerability?\n- The vulnerability is caused by insufficient throttling and limiting mechanism in the ANSL Server used the B\u0026R Automation Runtime.\n\nWhat might an attacker use the vulnerability to do?\n- An attacker who successfully exploited this vulnerability could cause the affected system node to stop.\n\nHow could an attacker exploit the vulnerability?\n- An attacker could try to exploit the vulnerability by creating a specially crafted message and sending the message to an affected system node. This would require that the attacker has access to the system network, by connecting to the net-work either directly or through a wrongly configured or penetrated firewall, or that he installs malicious software on a system node or otherwise infects the network with malicious software. Recommended practices help mitigate such attacks, see section Mitigating Factors above.\n\nCould the vulnerability be exploited remotely? \n- Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. \n\nWhat does the update do?\n- The update removes the vulnerability by limiting incoming network traffic that is handled by the ANSL server component.\n\nWhen this security advisory was issued, had this vulnerability been publicly disclosed?\n- No, B\u0026R discovered this vulnerability as a part of its own security analysis. \n\nWhen this security advisory was issued, had B\u0026R received any reports that this vulnerability was being exploited?\n- No, B\u0026R had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued.\n",
"title": "Frequently Asked Questions"
}
],
"publisher": {
"category": "vendor",
"name": "ABB PSIRT",
"namespace": "https://www.abb.com/global/en/company/about/cybersecurity/alerts-and-notifications"
},
"references": [
{
"category": "self",
"summary": "ABB CYBERSECURITY ADVISORY - PDF Version ",
"url": "https://www.br-automation.com/fileadmin/SA25P005-26597bd0.pdf"
},
{
"category": "self",
"summary": "ABB CYBERSECURITY ADVISORY - CSAF Version ",
"url": "https://psirt.abb.com/csaf/2026/sa25p005.json"
}
],
"title": "B\u0026R Automation Runtime Improper Handling of Flooding conditions on ANSL Server",
"tracking": {
"current_release_date": "2026-01-19T00:30:00.000Z",
"generator": {
"date": "2026-01-19T14:14:09.660Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.42"
}
},
"id": "SA25P005",
"initial_release_date": "2026-01-19T00:30:00.000Z",
"revision_history": [
{
"date": "2026-01-19T00:30:00.000Z",
"legacy_version": "A",
"number": "1",
"summary": "Initial version."
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c6.5",
"product": {
"name": "ABB Automation Runtime \u003c6.5",
"product_id": "AV1"
}
},
{
"category": "product_version_range",
"name": "\u003e=6.5",
"product": {
"name": "ABB Automation Runtime \u003e=6.5",
"product_id": "FX1"
}
},
{
"category": "product_version_range",
"name": "\u003cR4.93",
"product": {
"name": "ABB Automation Runtime \u003cR4.93",
"product_id": "AV2"
}
},
{
"category": "product_version_range",
"name": "\u003e=R4.93",
"product": {
"name": "ABB Automation Runtime \u003e=R4.93",
"product_id": "FX2"
}
}
],
"category": "product_name",
"name": "Automation Runtime"
}
],
"category": "vendor",
"name": "ABB"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-11044",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "description",
"text": "An Allocation of Resources Without Limits or Throttling vulnerability in the ANSL-Server component of B\u0026R Automation Runtime versions prior to 6.5 and prior to R4.93 could be exploited by an unauthenticated attacker on the net-work to win a race condition, resulting in permanent denial-of-service (DoS) conditions on affected devices.",
"title": "CVE description"
}
],
"product_status": {
"fixed": [
"FX1",
"FX2"
],
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2025-11044",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-11044"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "The problem is corrected in the following product versions:\n- Automation Runtime 6 versions \u003e= 6.5\n- Automation Runtime 4 versions \u003e= R4.93\n\nB\u0026R recommends that customers apply the update at earliest convenience.\n\nThe process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.\n",
"product_ids": [
"AV1",
"AV2"
]
},
{
"category": "mitigation",
"details": "The vulnerability cannot be exploited on all devices or across all customer applications. Extensive investigations by B\u0026R have determined that shorter cycle times in customer projects increase the likelihood of potential exploitation. For customers unable to transition to a patched version, adjusting their application configuration to longer cycle times may therefore be considered as a mitigating measure.\n\nB\u0026R Automation Runtime is designed to be operated on Level 1 of the ABB ICS Cyber Security Reference Architecture. Exploitation of the vulnerability from outside Level 1 would require an attacker to bypass the Control Network Firewall. Limiting the maximum data traffic and the maximum number of concurrent connections to the ANSL server of Automation Runtime on the Control Network Firewall, shall be considered to mitigate this vulnerability.\n\nB\u0026R further recommends, in alignment with its Defense in Depth for B\u0026R Products guidelines, that customers:\n- Test the maximum load capacity of their application under Automation Runtime before commissioning.\n- Restrict the permitted data traffic to the device via the Control Network Firewall to no more than 80% of the measured peak traffic value.\n\nRefer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"remediationLevel": "OFFICIAL_FIX",
"reportConfidence": "CONFIRMED",
"scope": "CHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H/RL:O/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2025-11044"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…