ssa-000072
Vulnerability from csaf_siemens
Published
2024-02-13 00:00
Modified
2024-03-12 00:00
Summary
SSA-000072: Multiple File Parsing Vulnerabilities in Simcenter Femap

Notes

Summary
Simcenter Femap contains multiple file parsing vulnerabilities that could be triggered when the application reads files in Catia MODEL file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "Simcenter Femap contains multiple file parsing vulnerabilities that could be triggered when the application reads files in Catia MODEL file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution.\n\nSiemens has released a new version for Simcenter Femap and recommends to update to the latest version.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-000072: Multiple File Parsing Vulnerabilities in Simcenter Femap - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-000072.html"
      },
      {
        "category": "self",
        "summary": "SSA-000072: Multiple File Parsing Vulnerabilities in Simcenter Femap - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-000072.json"
      },
      {
        "category": "self",
        "summary": "SSA-000072: Multiple File Parsing Vulnerabilities in Simcenter Femap - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-000072.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-000072: Multiple File Parsing Vulnerabilities in Simcenter Femap - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-000072.txt"
      }
    ],
    "title": "SSA-000072: Multiple File Parsing Vulnerabilities in Simcenter Femap",
    "tracking": {
      "current_release_date": "2024-03-12T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-000072",
      "initial_release_date": "2024-02-13T00:00:00Z",
      "revision_history": [
        {
          "date": "2024-02-13T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2024-03-12T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Added CVE-2024-27907 fixed in Simcenter Femap V2306.0000"
        }
      ],
      "status": "interim",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV2401.0000",
                "product": {
                  "name": "Simcenter Femap",
                  "product_id": "1"
                }
              },
              {
                "category": "product_version_range",
                "name": "\u003cV2306.0001",
                "product": {
                  "name": "Simcenter Femap",
                  "product_id": "2"
                }
              },
              {
                "category": "product_version_range",
                "name": "\u003cV2306.0000",
                "product": {
                  "name": "Simcenter Femap",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "Simcenter Femap"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2024-24920",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted Catia MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21710)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Do not open untrusted Catia MODEL files from using Simcenter Femap",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2401.0000 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2024-24920"
    },
    {
      "cve": "CVE-2024-24921",
      "cwe": {
        "id": "CWE-119",
        "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application is vulnerable to memory corruption while parsing specially crafted Catia MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21712)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Do not open untrusted Catia MODEL files from using Simcenter Femap",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2401.0000 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2024-24921"
    },
    {
      "cve": "CVE-2024-24922",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted Catia MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21715)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Do not open untrusted Catia MODEL files from using Simcenter Femap",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2401.0000 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2024-24922"
    },
    {
      "cve": "CVE-2024-24923",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted Catia MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22055)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Do not open untrusted Catia MODEL files from using Simcenter Femap",
          "product_ids": [
            "1",
            "2"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2306.0001 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2401.0000 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2024-24923"
    },
    {
      "cve": "CVE-2024-24924",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted Catia MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22059)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "3"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Do not open untrusted Catia MODEL files from using Simcenter Femap",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2306.0000 or later version",
          "product_ids": [
            "3"
          ],
          "url": "https://support.sw.siemens.com/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "3"
          ]
        }
      ],
      "title": "CVE-2024-24924"
    },
    {
      "cve": "CVE-2024-24925",
      "cwe": {
        "id": "CWE-824",
        "name": "Access of Uninitialized Pointer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted Catia MODEL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-22060)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "3"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Do not open untrusted Catia MODEL files from using Simcenter Femap",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2306.0000 or later version",
          "product_ids": [
            "3"
          ],
          "url": "https://support.sw.siemens.com/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "3"
          ]
        }
      ],
      "title": "CVE-2024-24925"
    },
    {
      "cve": "CVE-2024-27907",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted Catia MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22051)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "3"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Do not open untrusted Catia MODEL files from using Simcenter Femap",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2306.0000 or later version",
          "product_ids": [
            "3"
          ],
          "url": "https://support.sw.siemens.com/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "3"
          ]
        }
      ],
      "title": "CVE-2024-27907"
    }
  ]
}