SSA-384652
Vulnerability from csaf_siemens - Published: 2024-12-10 00:00 - Updated: 2024-12-10 00:00Summary
SSA-384652: Cross-Site Request Forgery (CSRF) Vulnerability in RUGGEDCOM ROX II
Notes
Summary
The CLI feature in the web interface of RUGGEDCOM ROX II devices is vulnerable to cross-site request forgery (CSRF), which could allow an attacker to perform administrative actions if an authenticated user is tricked into accessing a malicious link.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "The CLI feature in the web interface of RUGGEDCOM ROX II devices is vulnerable to cross-site request forgery (CSRF), which could allow an attacker to perform administrative actions if an authenticated user is tricked into accessing a malicious link.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-384652: Cross-Site Request Forgery (CSRF) Vulnerability in RUGGEDCOM ROX II - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-384652.html"
},
{
"category": "self",
"summary": "SSA-384652: Cross-Site Request Forgery (CSRF) Vulnerability in RUGGEDCOM ROX II - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-384652.json"
}
],
"title": "SSA-384652: Cross-Site Request Forgery (CSRF) Vulnerability in RUGGEDCOM ROX II",
"tracking": {
"current_release_date": "2024-12-10T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-384652",
"initial_release_date": "2024-12-10T00:00:00Z",
"revision_history": [
{
"date": "2024-12-10T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX MX5000",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX MX5000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX MX5000RE",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX MX5000RE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX RX1400",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX RX1500",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1500"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX RX1501",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1501"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX RX1510",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1510"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX RX1511",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1511"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX RX1512",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1512"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX RX1524",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1524"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX RX1536",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1536"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.16.0",
"product": {
"name": "RUGGEDCOM ROX RX5000",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX5000"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-28398",
"cwe": {
"id": "CWE-352",
"name": "Cross-Site Request Forgery (CSRF)"
},
"notes": [
{
"category": "summary",
"text": "The CLI feature in the web interface of affected devices is vulnerable to \r\ncross-site request forgery (CSRF).\r\n\r\nThis could allow an attacker to read or modify the device configuration\r\nby tricking an authenticated legitimate user into accessing a malicious link.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Only access links from trusted sources while authenticated in web interface of the affected devices",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.16.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109821187/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11"
]
}
],
"title": "CVE-2020-28398"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…