SSA-413407
Vulnerability from csaf_siemens - Published: 2021-09-14 00:00 - Updated: 2021-09-14 00:00Summary
SSA-413407: Path Traversal Vulnerability in Teamcenter Active Workspace
Notes
Summary
Teamcenter Active Workspace contains a path traversal vulnerability that could lead to access control violations.
Siemens has released updates for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{
"document": {
"acknowledgments": [
{
"names": [
"Christian Johansson",
"Mathias Kujala"
],
"organization": "Northvolt AB",
"summary": "reporting the vulnerability"
}
],
"category": "Siemens Security Advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Teamcenter Active Workspace contains a path traversal vulnerability that could lead to access control violations.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-413407: Path Traversal Vulnerability in Teamcenter Active Workspace - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413407.pdf"
},
{
"category": "self",
"summary": "SSA-413407: Path Traversal Vulnerability in Teamcenter Active Workspace - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-413407.txt"
},
{
"category": "self",
"summary": "SSA-413407: Path Traversal Vulnerability in Teamcenter Active Workspace - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-413407.json"
}
],
"title": "SSA-413407: Path Traversal Vulnerability in Teamcenter Active Workspace",
"tracking": {
"current_release_date": "2021-09-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-413407",
"initial_release_date": "2021-09-14T00:00:00Z",
"revision_history": [
{
"date": "2021-09-14T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V4.3.10",
"product": {
"name": "Teamcenter Active Workspace V4.3",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Teamcenter Active Workspace V4.3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V5.0.8",
"product": {
"name": "Teamcenter Active Workspace V5.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Teamcenter Active Workspace V5.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V5.1.5",
"product": {
"name": "Teamcenter Active Workspace V5.1",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Teamcenter Active Workspace V5.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V5.2.1",
"product": {
"name": "Teamcenter Active Workspace V5.2",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Teamcenter Active Workspace V5.2"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-40357",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A path traversal vulnerability in the application could allow an attacker to bypass certain restrictions such as direct access to other services within the host.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2021-40357 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-40357.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V4.3.10 or later version",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.0.8 or later version",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.1.5 or later version",
"product_ids": [
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.2.1 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "Harden the application host to prevent local access by untrusted personnel",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2021-40357"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…