SSA-517338

Vulnerability from csaf_siemens - Published: 2025-08-12 00:00 - Updated: 2025-08-12 00:00
Summary
SSA-517338: Multiple Vulnerabilities in SINEC Traffic Analyzer Before V3.0

Notes

Summary
SINEC Traffic Analyzer before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "SINEC Traffic Analyzer before V3.0 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-517338: Multiple Vulnerabilities in SINEC Traffic Analyzer Before V3.0 - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-517338.html"
      },
      {
        "category": "self",
        "summary": "SSA-517338: Multiple Vulnerabilities in SINEC Traffic Analyzer Before V3.0 - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-517338.json"
      }
    ],
    "title": "SSA-517338: Multiple Vulnerabilities in SINEC Traffic Analyzer Before V3.0",
    "tracking": {
      "current_release_date": "2025-08-12T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-517338",
      "initial_release_date": "2025-08-12T00:00:00Z",
      "revision_history": [
        {
          "date": "2025-08-12T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "interim",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.0",
                "product": {
                  "name": "SINEC Traffic Analyzer (6GK8822-1BG01-0BA0)",
                  "product_id": "1",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK8822-1BG01-0BA0"
                    ]
                  }
                }
              },
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SINEC Traffic Analyzer (6GK8822-1BG01-0BA0)",
                  "product_id": "2",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK8822-1BG01-0BA0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SINEC Traffic Analyzer (6GK8822-1BG01-0BA0)"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2024-24989",
      "cwe": {
        "id": "CWE-476",
        "name": "NULL Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "When NGINX Plus or NGINX OSS are configured to use the HTTP/3 QUIC module, undisclosed requests can cause NGINX worker processes to terminate.\n\nNote: The HTTP/3 QUIC module is not enabled by default and is considered experimental. For more information, refer to  Support for QUIC and HTTP/3 https://nginx.org/en/docs/quic.html .\n\n\n\nNOTE: Software versions which have reached End of Technical Support (EoTS) are not evaluated",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109987676/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2024-24989"
    },
    {
      "cve": "CVE-2024-24990",
      "cwe": {
        "id": "CWE-416",
        "name": "Use After Free"
      },
      "notes": [
        {
          "category": "summary",
          "text": "When NGINX Plus or NGINX OSS are configured to use the HTTP/3 QUIC module, undisclosed requests can cause NGINX worker processes to terminate.\n\nNote: The HTTP/3 QUIC module is not enabled by default and is considered experimental. For more information, refer to  Support for QUIC and HTTP/3 https://nginx.org/en/docs/quic.html .\n\n\n\n \n\n\nNote: Software versions which have reached End of Technical Support (EoTS) are not evaluated",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109987676/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2024-24990"
    },
    {
      "cve": "CVE-2025-40766",
      "cwe": {
        "id": "CWE-400",
        "name": "Uncontrolled Resource Consumption"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application runs docker containers without adequate resource and security limitations. This could allow an attacker to perform a denial-of-service (DoS) attack.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109987676/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40766"
    },
    {
      "cve": "CVE-2025-40767",
      "cwe": {
        "id": "CWE-250",
        "name": "Execution with Unnecessary Privileges"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application runs docker containers without adequate security controls to enforce isolation. This could allow an attacker to gain elevated access, potentially accessing sensitive host system resources.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109987676/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40767"
    },
    {
      "cve": "CVE-2025-40768",
      "cwe": {
        "id": "CWE-200",
        "name": "Exposure of Sensitive Information to an Unauthorized Actor"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application exposes an internal service port to be accessible from outside the system. This could allow an unauthorized attacker to access the application.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109987676/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40768"
    },
    {
      "cve": "CVE-2025-40769",
      "cwe": {
        "id": "CWE-1164",
        "name": "Irrelevant Code"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application uses a Content Security Policy that allows unsafe script execution methods. This could allow an attacker to execute unauthorized scripts, potentially leading to cross-site scripting attacks.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109987676/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40769"
    },
    {
      "cve": "CVE-2025-40770",
      "cwe": {
        "id": "CWE-300",
        "name": "Channel Accessible by Non-Endpoint"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application uses a monitoring interface that is not operating in a strictly passive mode. This could allow an attacker to interact with the interface, leading to man-in-the-middle attacks.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "2"
        ]
      },
      "remediations": [
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "2"
          ]
        }
      ],
      "title": "CVE-2025-40770"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…