SSA-534763

Vulnerability from csaf_siemens - Published: 2020-09-08 00:00 - Updated: 2022-03-08 00:00
Summary
SSA-534763: Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products

Notes

Summary
Security researchers published information on a vulnerability known as Crosstalk (INTEL-SA-00320). This vulnerability affects modern Intel processors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerability. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.

{
  "document": {
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "Security researchers published information on a vulnerability known as Crosstalk (INTEL-SA-00320). This vulnerability affects modern Intel processors to a varying degree.\n\nSeveral Siemens Industrial Products contain processors that are affected by the vulnerability.\n\nSiemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-534763: Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-534763.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-534763: Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-534763.txt"
      },
      {
        "category": "self",
        "summary": "SSA-534763: Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-534763.json"
      }
    ],
    "title": "SSA-534763: Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products",
    "tracking": {
      "current_release_date": "2022-03-08T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-534763",
      "initial_release_date": "2020-09-08T00:00:00Z",
      "revision_history": [
        {
          "date": "2020-09-08T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2020-10-13T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Removed SINUMERIK 840D sl (NCU730.3B), SINUMERIK 828D (PPU.4 / PPU1740), and SINUMERIK ONE (NCU1750 / NCU1760) from the list of affected products. Added solution for SIMATIC IPC627E, SIMATIC IPC647E, SIMATIC IPC677E, and SIMATIC IPC847E"
        },
        {
          "date": "2020-12-08T00:00:00Z",
          "legacy_version": "1.2",
          "number": "3",
          "summary": "Added solution for SIMATIC IPC427E, SIMATIC IPC477E, and SIMATIC IPC477E PRO"
        },
        {
          "date": "2021-02-09T00:00:00Z",
          "legacy_version": "1.3",
          "number": "4",
          "summary": "Added solution for SIMATIC Field PG M5, and SIMATIC Field PG M6"
        },
        {
          "date": "2021-04-13T00:00:00Z",
          "legacy_version": "1.4",
          "number": "5",
          "summary": "Added solution for SIMATIC ITP1000 and SIMATIC IPC547G"
        },
        {
          "date": "2021-06-08T00:00:00Z",
          "legacy_version": "1.5",
          "number": "6",
          "summary": "Added solution for SIMATIC IPC527G"
        },
        {
          "date": "2022-03-08T00:00:00Z",
          "legacy_version": "1.6",
          "number": "7",
          "summary": "Added solution for SIMATIC IPC3000 SMART V2 and clarified that no further fixes are planned"
        }
      ],
      "status": "final",
      "version": "7"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC Field PG M4",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M4"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V22.01.08",
                "product": {
                  "name": "SIMATIC Field PG M5",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M5"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V26.01.07",
                "product": {
                  "name": "SIMATIC Field PG M6",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M6"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC347E",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC347E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC427D (incl. SIPLUS variants)",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC427D (incl. SIPLUS variants)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V21.01.14",
                "product": {
                  "name": "SIMATIC IPC427E (incl. SIPLUS variants)",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC427E (incl. SIPLUS variants)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC477D",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477D"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V21.01.14",
                "product": {
                  "name": "SIMATIC IPC477E",
                  "product_id": "8"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V21.01.14",
                "product": {
                  "name": "SIMATIC IPC477E Pro",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477E Pro"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V1.4.0",
                "product": {
                  "name": "SIMATIC IPC527G",
                  "product_id": "10"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC527G"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC547E",
                  "product_id": "11"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC547E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c R1.28.0",
                "product": {
                  "name": "SIMATIC IPC547G",
                  "product_id": "12"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC547G"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC627D",
                  "product_id": "13"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC627D"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.06",
                "product": {
                  "name": "SIMATIC IPC627E",
                  "product_id": "14"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC627E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC647D",
                  "product_id": "15"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC647D"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.06",
                "product": {
                  "name": "SIMATIC IPC647E",
                  "product_id": "16"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC647E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC677D",
                  "product_id": "17"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC677D"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.06",
                "product": {
                  "name": "SIMATIC IPC677E",
                  "product_id": "18"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC677E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC827D",
                  "product_id": "19"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC827D"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC847D",
                  "product_id": "20"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC847D"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.06",
                "product": {
                  "name": "SIMATIC IPC847E",
                  "product_id": "21"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC847E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V1.B",
                "product": {
                  "name": "SIMATIC IPC3000 SMART V2",
                  "product_id": "22"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC3000 SMART V2"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V23.01.08",
                "product": {
                  "name": "SIMATIC ITP1000",
                  "product_id": "23"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITP1000"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMOTION P320-4E",
                  "product_id": "24"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMOTION P320-4E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMOTION P320-4S",
                  "product_id": "25"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMOTION P320-4S"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2020-0543",
      "cwe": {
        "id": "CWE-200",
        "name": "Exposure of Sensitive Information to an Unauthorized Actor"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Incomplete cleanup from specific special register read operations in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15",
          "16",
          "17",
          "18",
          "19",
          "20",
          "21",
          "22",
          "23",
          "24",
          "25"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-0543 - SIMATIC Field PG M5",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC Field PG M6",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC IPC427E (incl. SIPLUS variants)",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC IPC477E",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC IPC477E Pro",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC IPC527G",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC IPC547G",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC IPC627E",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC IPC647E",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC IPC677E",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC IPC847E",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC IPC3000 SMART V2",
          "url": "https://support.industry.siemens.com/cs/cn/en/view/109763408/"
        },
        {
          "summary": "CVE-2020-0543 - SIMATIC ITP1000",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "summary": "CVE-2020-0543 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-0543.json"
        }
      ],
      "remediations": [
        {
          "category": "no_fix_planned",
          "details": "Currently no remediation is planned",
          "product_ids": [
            "1",
            "4",
            "5",
            "7",
            "11",
            "13",
            "15",
            "17",
            "19",
            "20",
            "24",
            "25"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.08",
          "product_ids": [
            "2"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.07",
          "product_ids": [
            "3"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.14",
          "product_ids": [
            "6",
            "8",
            "9"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V1.4.0",
          "product_ids": [
            "10"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to R1.28.0",
          "product_ids": [
            "12"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.06",
          "product_ids": [
            "14",
            "16",
            "18",
            "21"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V1.B or later version",
          "product_ids": [
            "22"
          ],
          "url": "https://support.industry.siemens.com/cs/cn/en/view/109763408/"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.08",
          "product_ids": [
            "23"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15",
            "16",
            "17",
            "18",
            "19",
            "20",
            "21",
            "22",
            "23",
            "24",
            "25"
          ]
        },
        {
          "category": "mitigation",
          "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15",
            "16",
            "17",
            "18",
            "19",
            "20",
            "21",
            "22",
            "23",
            "24",
            "25"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15",
            "16",
            "17",
            "18",
            "19",
            "20",
            "21",
            "22",
            "23",
            "24",
            "25"
          ]
        }
      ],
      "title": "CVE-2020-0543"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…