SSA-614723
Vulnerability from csaf_siemens - Published: 2025-05-13 00:00 - Updated: 2025-10-14 00:00Summary
SSA-614723: Denial of Service Vulnerabilities in User Management Component (UMC)
Notes
Summary
Siemens User Management Component (UMC) is affected by three vulnerabilities which could allow an unauthenticated remote attacker to cause a denial of service condition.
Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Siemens User Management Component (UMC) is affected by three vulnerabilities which could allow an unauthenticated remote attacker to cause a denial of service condition.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-614723: Denial of Service Vulnerabilities in User Management Component (UMC) - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-614723.html"
},
{
"category": "self",
"summary": "SSA-614723: Denial of Service Vulnerabilities in User Management Component (UMC) - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-614723.json"
}
],
"title": "SSA-614723: Denial of Service Vulnerabilities in User Management Component (UMC)",
"tracking": {
"current_release_date": "2025-10-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-614723",
"initial_release_date": "2025-05-13T00:00:00Z",
"revision_history": [
{
"date": "2025-05-13T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-07-08T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for SINEC NMS V4.0"
},
{
"date": "2025-10-14T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added No fix planned for PCS Neo V5"
}
],
"status": "interim",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS neo V4.1",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS neo V4.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS neo V5.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS neo V5.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.0",
"product": {
"name": "SINEC NMS",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SINEC NMS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINEMA Remote Connect",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SINEMA Remote Connect"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V17",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V18",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V18"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V19",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V19"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V20",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V20"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.15.1.1",
"product": {
"name": "User Management Component (UMC)",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "User Management Component (UMC)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-30174",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
"remediations": [
{
"category": "mitigation",
"details": "In non-networked scenarios/deployments block TCP ports 4002 and 4004 on machines with UMC installed. In addition if no RT server machines are used, port 4004 can be blocked completely",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.15.1.1 or later version",
"product_ids": [
"9"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109987708/"
},
{
"category": "vendor_fix",
"details": "Update to V4.0 or later version",
"product_ids": [
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109989514/"
},
{
"category": "vendor_fix",
"details": "Update UMC to V2.15.1.1 or later compatible version https://support.industry.siemens.com/cs/ww/en/view/109987708/",
"product_ids": [
"4"
]
},
{
"category": "vendor_fix",
"details": "Update UMC to V2.15.1.1 or later compatible version\nhttps://support.industry.siemens.com/cs/ww/en/view/109987708/",
"product_ids": [
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
}
],
"title": "CVE-2025-30174"
},
{
"cve": "CVE-2025-30175",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
"remediations": [
{
"category": "mitigation",
"details": "In non-networked scenarios/deployments block TCP ports 4002 and 4004 on machines with UMC installed. In addition if no RT server machines are used, port 4004 can be blocked completely",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.15.1.1 or later version",
"product_ids": [
"9"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109987708/"
},
{
"category": "vendor_fix",
"details": "Update to V4.0 or later version",
"product_ids": [
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109989514/"
},
{
"category": "vendor_fix",
"details": "Update UMC to V2.15.1.1 or later compatible version https://support.industry.siemens.com/cs/ww/en/view/109987708/",
"product_ids": [
"4"
]
},
{
"category": "vendor_fix",
"details": "Update UMC to V2.15.1.1 or later compatible version\nhttps://support.industry.siemens.com/cs/ww/en/view/109987708/",
"product_ids": [
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
}
],
"title": "CVE-2025-30175"
},
{
"cve": "CVE-2025-30176",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
"remediations": [
{
"category": "mitigation",
"details": "In non-networked scenarios/deployments block TCP ports 4002 and 4004 on machines with UMC installed. In addition if no RT server machines are used, port 4004 can be blocked completely",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.15.1.1 or later version",
"product_ids": [
"9"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109987708/"
},
{
"category": "vendor_fix",
"details": "Update to V4.0 or later version",
"product_ids": [
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109989514/"
},
{
"category": "vendor_fix",
"details": "Update UMC to V2.15.1.1 or later compatible version https://support.industry.siemens.com/cs/ww/en/view/109987708/",
"product_ids": [
"4"
]
},
{
"category": "vendor_fix",
"details": "Update UMC to V2.15.1.1 or later compatible version\nhttps://support.industry.siemens.com/cs/ww/en/view/109987708/",
"product_ids": [
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
}
],
"title": "CVE-2025-30176"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…