SSA-621657

Vulnerability from csaf_siemens - Published: 2026-08-11 00:00 - Updated: 2026-08-11 00:00
Summary
SSA-621657: File Parsing Vulnerabilities in Solid Edge Before Version SE2026 Update 7
Notes
Summary: Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

The affected applications contains an out of bounds read vulnerability while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.

CWE-125 - Out-of-bounds Read
Affected products
Product Identifier Version Remediation
Solid Edge SE2025 < V225.0.15
Siemens / Solid Edge SE2025
vers:intdot/<225.0.15
Vendor Fix fix
Solid Edge SE2026 < V226.0.7
Siemens / Solid Edge SE2026
vers:intdot/<226.0.7
Vendor Fix fix

The affected applications contains an out of bounds write vulnerability while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.

CWE-787 - Out-of-bounds Write
Affected products
Product Identifier Version Remediation
Solid Edge SE2025 < V225.0.15
Siemens / Solid Edge SE2025
vers:intdot/<225.0.15
Vendor Fix fix
Solid Edge SE2026 < V226.0.7
Siemens / Solid Edge SE2026
vers:intdot/<226.0.7
Vendor Fix fix

The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.

CWE-416 - Use After Free
Affected products
Product Identifier Version Remediation
Solid Edge SE2025 < V225.0.15
Siemens / Solid Edge SE2025
vers:intdot/<225.0.15
Vendor Fix fix
Solid Edge SE2026 < V226.0.7
Siemens / Solid Edge SE2026
vers:intdot/<226.0.7
Vendor Fix fix

The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.

CWE-416 - Use After Free
Affected products
Product Identifier Version Remediation
Solid Edge SE2025 < V225.0.15
Siemens / Solid Edge SE2025
vers:intdot/<225.0.15
Vendor Fix fix
Solid Edge SE2026 < V226.0.7
Siemens / Solid Edge SE2026
vers:intdot/<226.0.7
Vendor Fix fix

The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

CWE-125 - Out-of-bounds Read
Affected products
Product Identifier Version Remediation
Solid Edge SE2025 < V225.0.15
Siemens / Solid Edge SE2025
vers:intdot/<225.0.15
Vendor Fix fix
Solid Edge SE2026 < V226.0.7
Siemens / Solid Edge SE2026
vers:intdot/<226.0.7
Vendor Fix fix

The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

CWE-125 - Out-of-bounds Read
Affected products
Product Identifier Version Remediation
Solid Edge SE2025 < V225.0.15
Siemens / Solid Edge SE2025
vers:intdot/<225.0.15
Vendor Fix fix
Solid Edge SE2026 < V226.0.7
Siemens / Solid Edge SE2026
vers:intdot/<226.0.7
Vendor Fix fix

The affected applications contains an out of bounds write vulnerability while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.

CWE-787 - Out-of-bounds Write
Affected products
Product Identifier Version Remediation
Solid Edge SE2025 < V225.0.15
Siemens / Solid Edge SE2025
vers:intdot/<225.0.15
Vendor Fix fix
Solid Edge SE2026 < V226.0.7
Siemens / Solid Edge SE2026
vers:intdot/<226.0.7
Vendor Fix fix

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-621657: File Parsing Vulnerabilities in Solid Edge Before Version SE2026 Update 7 - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-621657.html"
      },
      {
        "category": "self",
        "summary": "SSA-621657: File Parsing Vulnerabilities in Solid Edge Before Version SE2026 Update 7 - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-621657.json"
      }
    ],
    "title": "SSA-621657: File Parsing Vulnerabilities in Solid Edge Before Version SE2026 Update 7",
    "tracking": {
      "current_release_date": "2026-08-11T00:00:00.000Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-621657",
      "initial_release_date": "2026-08-11T00:00:00.000Z",
      "revision_history": [
        {
          "date": "2026-08-11T00:00:00.000Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "interim",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c225.0.15",
                "product": {
                  "name": "Solid Edge SE2025 \u003c V225.0.15",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "Solid Edge SE2025"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c226.0.7",
                "product": {
                  "name": "Solid Edge SE2026 \u003c V226.0.7",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "Solid Edge SE2026"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2026-50058",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "description",
          "text": "The affected applications contains an out of bounds read vulnerability while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V225.0 Update 15 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V226.0 Update 7 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2026-50058"
    },
    {
      "cve": "CVE-2026-50059",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "description",
          "text": "The affected applications contains an out of bounds write vulnerability while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V225.0 Update 15 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V226.0 Update 7 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2026-50059"
    },
    {
      "cve": "CVE-2026-50060",
      "cwe": {
        "id": "CWE-416",
        "name": "Use After Free"
      },
      "notes": [
        {
          "category": "description",
          "text": "The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V225.0 Update 15 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V226.0 Update 7 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2026-50060"
    },
    {
      "cve": "CVE-2026-50061",
      "cwe": {
        "id": "CWE-416",
        "name": "Use After Free"
      },
      "notes": [
        {
          "category": "description",
          "text": "The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V225.0 Update 15 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V226.0 Update 7 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2026-50061"
    },
    {
      "cve": "CVE-2026-50062",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "description",
          "text": "The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V225.0 Update 15 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V226.0 Update 7 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2026-50062"
    },
    {
      "cve": "CVE-2026-50063",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "description",
          "text": "The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V225.0 Update 15 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V226.0 Update 7 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2026-50063"
    },
    {
      "cve": "CVE-2026-50064",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "description",
          "text": "The affected applications contains an out of bounds write vulnerability while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V225.0 Update 15 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V226.0 Update 7 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2026-50064"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Loading…