SSA-868571

Vulnerability from csaf_siemens - Published: 2025-12-09 00:00 - Updated: 2025-12-09 00:00
Summary
SSA-868571: Missing Server Certificate Validation in IAM Client

Notes

Summary
Multiple Siemens products are affected by improper certificate validation in IAM Client. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "Multiple Siemens products are affected by improper certificate validation in IAM Client. This could allow an unauthenticated remote attacker to perform man in the middle attacks.\n\nSiemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-868571: Missing Server Certificate Validation in IAM Client - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-868571.html"
      },
      {
        "category": "self",
        "summary": "SSA-868571: Missing Server Certificate Validation in IAM Client - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-868571.json"
      }
    ],
    "title": "SSA-868571: Missing Server Certificate Validation in IAM Client",
    "tracking": {
      "current_release_date": "2025-12-09T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-868571",
      "initial_release_date": "2025-12-09T00:00:00Z",
      "revision_history": [
        {
          "date": "2025-12-09T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "interim",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "COMOS V10.6",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "COMOS V10.6"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c2412.8700",
                "product": {
                  "name": "NX V2412",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "NX V2412"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c2506.6000",
                "product": {
                  "name": "NX V2506",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "NX V2506"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c2506.6000",
                "product": {
                  "name": "Simcenter 3D",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "Simcenter 3D"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c2506.0002",
                "product": {
                  "name": "Simcenter Femap",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "Simcenter Femap"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V225.0 Update 10",
                "product": {
                  "name": "Solid Edge SE2025",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "Solid Edge SE2025"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V226.0 Update 1",
                "product": {
                  "name": "Solid Edge SE2026",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "Solid Edge SE2026"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2025-40800",
      "cwe": {
        "id": "CWE-295",
        "name": "Improper Certificate Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7"
        ]
      },
      "remediations": [
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V225.0 Update 10 or later version",
          "product_ids": [
            "6"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V226.0 Update 1 or later version",
          "product_ids": [
            "7"
          ],
          "url": "https://support.sw.siemens.com/product/246738425/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2412.8700 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/product/209349590/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2506.0002 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.sw.siemens.com/product/275652363/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2506.6000 or later version",
          "product_ids": [
            "3"
          ],
          "url": "https://support.sw.siemens.com/product/209349590/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2506.6000 or later version",
          "product_ids": [
            "4"
          ],
          "url": "https://support.sw.siemens.com/product/289054037/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7"
          ]
        }
      ],
      "title": "CVE-2025-40800"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…