SSA-997732

Vulnerability from csaf_siemens - Published: 2021-09-14 00:00 - Updated: 2021-09-14 00:00
Summary
SSA-997732: Modfem File Parsing Vulnerability in Simcenter Femap before V2021.2

Notes

Summary
Siemens Simcenter Femap is affected by a vulnerability that could be triggered when the application reads modfem files. If a user is tricked to open a malicious file with the affected application, an attacker could leverage this vulnerability to leak information in the context of the current process. Siemens recommends to update to the latest version line of Simcenter Femap (2021.2), which is not affected by this type of vulnerabilities. Siemens recommends to avoid opening of untrusted files from unknown sources.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.

{
  "document": {
    "acknowledgments": [
      {
        "organization": "Trend Micro Zero Day Initiative",
        "summary": "coordinated disclosure"
      }
    ],
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "Siemens Simcenter Femap is affected by a vulnerability that could be triggered when the application reads modfem files. If a user is tricked to open a malicious file with the affected application, an attacker could leverage this vulnerability to leak information in the context of the current process.\n\nSiemens recommends to update to the latest version line of Simcenter Femap (2021.2), which is not affected by this type of vulnerabilities. Siemens recommends to avoid opening of untrusted files from unknown sources.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-997732: Modfem File Parsing Vulnerability in Simcenter Femap before V2021.2 - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-997732.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-997732: Modfem File Parsing Vulnerability in Simcenter Femap before V2021.2 - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-997732.txt"
      },
      {
        "category": "self",
        "summary": "SSA-997732: Modfem File Parsing Vulnerability in Simcenter Femap before V2021.2 - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-997732.json"
      }
    ],
    "title": "SSA-997732: Modfem File Parsing Vulnerability in Simcenter Femap before V2021.2",
    "tracking": {
      "current_release_date": "2021-09-14T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-997732",
      "initial_release_date": "2021-09-14T00:00:00Z",
      "revision_history": [
        {
          "date": "2021-09-14T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Simcenter Femap V2020.2",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "Simcenter Femap V2020.2"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Simcenter Femap V2021.1",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "Simcenter Femap V2021.1"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2021-37176",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The femap.exe application lacks proper validation of user-supplied data when parsing modfem files. This could result in an out of bounds read past the end of an allocated buffer.\n\nAn attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14260)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-37176 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37176.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V2021.2 or later version",
          "product_ids": [
            "1",
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Do not open untrusted modfem files from unknown sources",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-37176"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…