Action not permitted
Modal body text goes here.
Modal Title
Modal Body
tid-322
Vulnerability from emb3d
Type
Description
If a threat actor can include malicious JavaScript within a page viewed by a legitimate device user, that script can send malicious authenticated HTTP requests (using XMLHttpRequest) to the device. Due to the Same Origin Policy defined by most web browsers, the HTTP requests sent to the device will include any valid session tokens the user/browser has previously established for that device. Therefore, this could be used to send malicious requests to a device to change key functions or configurations, including changing device credentials. This requires that the threat actor tricks the user into viewing another page while they have an authenticated session with the device.
CWE
- CWE-352: Cross-Site Request Forgery (CSRF) (Compound)
CVE-2016-5809 (GCVE-0-2016-5809)
Vulnerability from cvelistv5 – Published: 2017-02-13 21:00 – Updated: 2024-08-06 01:15
VLAI?
EPSS
Summary
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.
Severity ?
No CVSS data available.
CWE
- Schneider Electric IONXXXX Series csrf
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Schneider Electric IONXXXX Series |
Affected:
Schneider Electric IONXXXX Series
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:15:10.763Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "44640",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/44640/"
},
{
"name": "92916",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/92916"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Schneider Electric IONXXXX Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Schneider Electric IONXXXX Series"
}
]
}
],
"datePublic": "2017-02-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Schneider Electric IONXXXX Series csrf",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-05-19T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "44640",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/44640/"
},
{
"name": "92916",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/92916"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2016-5809",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Schneider Electric IONXXXX Series",
"version": {
"version_data": [
{
"version_value": "Schneider Electric IONXXXX Series"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Schneider Electric IONXXXX Series csrf"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "44640",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/44640/"
},
{
"name": "92916",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/92916"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2016-5809",
"datePublished": "2017-02-13T21:00:00",
"dateReserved": "2016-06-23T00:00:00",
"dateUpdated": "2024-08-06T01:15:10.763Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-5698 (GCVE-0-2015-5698)
Vulnerability from cvelistv5 – Published: 2015-08-30 00:00 – Updated: 2024-08-06 06:59
VLAI?
EPSS
Summary
Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T06:59:03.900Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1033419",
"tags": [
"vdb-entry",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1033419"
},
{
"tags": [
"x_transferred"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-134003.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-239-02"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-134003.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/172315/Siemens-SIMATIC-S7-1200-Cross-Site-Request-Forgery.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-08-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-15T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "1033419",
"tags": [
"vdb-entry"
],
"url": "http://www.securitytracker.com/id/1033419"
},
{
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-134003.pdf"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-239-02"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-134003.pdf"
},
{
"url": "http://packetstormsecurity.com/files/172315/Siemens-SIMATIC-S7-1200-Cross-Site-Request-Forgery.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-5698",
"datePublished": "2015-08-30T00:00:00",
"dateReserved": "2015-07-29T00:00:00",
"dateUpdated": "2024-08-06T06:59:03.900Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-3950 (GCVE-0-2015-3950)
Vulnerability from cvelistv5 – Published: 2015-06-05 10:00 – Updated: 2024-08-06 06:04
VLAI?
EPSS
Summary
Cross-site request forgery (CSRF) vulnerability in XZERES 442SR OS on 442SR wind turbines allows remote attackers to hijack the authentication of admins for requests that select a different default admin user via a GET request.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T06:04:01.119Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-155-01"
},
{
"name": "75032",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/75032"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-06-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in XZERES 442SR OS on 442SR wind turbines allows remote attackers to hijack the authentication of admins for requests that select a different default admin user via a GET request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-02T20:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-155-01"
},
{
"name": "75032",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/75032"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2015-3950",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability in XZERES 442SR OS on 442SR wind turbines allows remote attackers to hijack the authentication of admins for requests that select a different default admin user via a GET request."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-155-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-155-01"
},
{
"name": "75032",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/75032"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2015-3950",
"datePublished": "2015-06-05T10:00:00",
"dateReserved": "2015-05-12T00:00:00",
"dateUpdated": "2024-08-06T06:04:01.119Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2358 (GCVE-0-2014-2358)
Vulnerability from cvelistv5 – Published: 2014-10-19 01:00 – Updated: 2025-10-03 17:19
VLAI?
EPSS
Summary
Multiple cross-site request forgery (CSRF) vulnerabilities in the administrative web interface in the proxy server on Fox-IT Fox DataDiode appliances before 1.7.2 allow remote attackers to hijack the authentication of administrators for requests that (1) create administrative users, (2) remove administrative users, or (3) change permissions.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fox-IT | DataDiode Appliance |
Affected:
0 , ≤ 1.7.1
(custom)
Unaffected: 1.7.2 |
Credits
Tudor Enache of HelpAG
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:14:25.516Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-269-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DataDiode Appliance",
"vendor": "Fox-IT",
"versions": [
{
"lessThanOrEqual": "1.7.1",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.7.2"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Tudor Enache of HelpAG"
}
],
"datePublic": "2014-10-16T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMultiple cross-site request forgery (CSRF) vulnerabilities in the administrative web interface in the proxy server on Fox-IT Fox DataDiode appliances before 1.7.2 allow remote attackers to hijack the authentication of administrators for requests that (1) create administrative users, (2) remove administrative users, or (3) change permissions.\u003c/p\u003e"
}
],
"value": "Multiple cross-site request forgery (CSRF) vulnerabilities in the administrative web interface in the proxy server on Fox-IT Fox DataDiode appliances before 1.7.2 allow remote attackers to hijack the authentication of administrators for requests that (1) create administrative users, (2) remove administrative users, or (3) change permissions."
}
],
"metrics": [
{
"cvssV2_0": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-03T17:19:27.344Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-269-02"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eFox-IT has released Version 1.7.2 of the Fox DataDiode Appliance that\n resolves the reported vulnerability. A Fox-IT product advisory titled \n\u201cFox DataDiode Appliance 1.7.2 advisory,\u201d containing background and \npreparation information, as well as the upgrade instructions, are \navailable by contacting the local Fox-IT customer support.\u003c/p\u003e\n\u003cp\u003eFox-IT also recommends the following actions:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll users of the Fox DataDiode Appliance should upgrade their systems to Version 1.7.2.\u003c/li\u003e\n\u003cli\u003eThis installation consists of a reinstallation of the new version of\n the software. Therefore, the existing software configuration should be \nexported before this upgrade. This configuration can then be restored \nafter the upgrade.\u003c/li\u003e\n\u003cli\u003eUsers are advised to change all passwords of administrator and user \naccounts in the Fox DataDiode Appliance, plus passwords used for FTP/SSL\n connections.\u003c/li\u003e\n\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "Fox-IT has released Version 1.7.2 of the Fox DataDiode Appliance that\n resolves the reported vulnerability. A Fox-IT product advisory titled \n\u201cFox DataDiode Appliance 1.7.2 advisory,\u201d containing background and \npreparation information, as well as the upgrade instructions, are \navailable by contacting the local Fox-IT customer support.\n\n\nFox-IT also recommends the following actions:\n\n\n\n * All users of the Fox DataDiode Appliance should upgrade their systems to Version 1.7.2.\n\n * This installation consists of a reinstallation of the new version of\n the software. Therefore, the existing software configuration should be \nexported before this upgrade. This configuration can then be restored \nafter the upgrade.\n\n * Users are advised to change all passwords of administrator and user \naccounts in the Fox DataDiode Appliance, plus passwords used for FTP/SSL\n connections."
}
],
"source": {
"advisory": "ICSA-14-269-02",
"discovery": "EXTERNAL"
},
"title": "Fox-IT DataDiode Appliance CSRF",
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-2358",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple cross-site request forgery (CSRF) vulnerabilities in the administrative web interface in the proxy server on Fox-IT Fox DataDiode appliances before 1.7.2 allow remote attackers to hijack the authentication of administrators for requests that (1) create administrative users, (2) remove administrative users, or (3) change permissions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-269-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-269-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-2358",
"datePublished": "2014-10-19T01:00:00",
"dateReserved": "2014-03-13T00:00:00",
"dateUpdated": "2025-10-03T17:19:27.344Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-14783 (GCVE-0-2018-14783)
Vulnerability from cvelistv5 – Published: 2018-08-10 19:00 – Updated: 2024-09-16 16:13
VLAI?
EPSS
Summary
NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. A cross-site request forgery condition can occur, allowing an attacker to change passwords of the device remotely.
Severity ?
No CVSS data available.
CWE
- CWE-352 - CROSS-SITE REQUEST FORGERY CWE-352
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| ICS-CERT | NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. |
Affected:
NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:38:14.073Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-02"
},
{
"name": "105053",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105053"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior.",
"vendor": "ICS-CERT",
"versions": [
{
"status": "affected",
"version": "NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior."
}
]
}
],
"datePublic": "2018-08-09T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. A cross-site request forgery condition can occur, allowing an attacker to change passwords of the device remotely."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CROSS-SITE REQUEST FORGERY CWE-352",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-14T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-02"
},
{
"name": "105053",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105053"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-09T00:00:00",
"ID": "CVE-2018-14783",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior.",
"version": {
"version_data": [
{
"version_value": "NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior."
}
]
}
}
]
},
"vendor_name": "ICS-CERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. A cross-site request forgery condition can occur, allowing an attacker to change passwords of the device remotely."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CROSS-SITE REQUEST FORGERY CWE-352"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-02"
},
{
"name": "105053",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105053"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-14783",
"datePublished": "2018-08-10T19:00:00Z",
"dateReserved": "2018-08-01T00:00:00",
"dateUpdated": "2024-09-16T16:13:07.238Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…