VAR-201501-0402
Vulnerability from variot - Updated: 2023-12-18 12:30The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request. Supplementary information : CWE Vulnerability type by CWE-284: Improper Access Control ( Inappropriate access control ) Has been identified. Schneider Electric ETG3000 FactoryCast HMI Gateway is a web-based SCADA system. The vulnerability is caused by the program not enforcing adequate access controls when storing the rde.jar file in the web root directory
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201501-0402",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "etg3000 factorycast hmi gateway",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "1.60.2"
},
{
"model": "tsxetg3021",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3022",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3010",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3000",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway",
"scope": "lt",
"trust": 0.8,
"vendor": "schneider electric",
"version": "1.60 ir 04"
},
{
"model": "tsxetg3000",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3010",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3021",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3022",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "electric etg3000 factorycast hmi gateway",
"scope": null,
"trust": 0.6,
"vendor": "schneider",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway tsxetg3022",
"scope": null,
"trust": 0.3,
"vendor": "schneider electric",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway tsxetg3021",
"scope": null,
"trust": 0.3,
"vendor": "schneider electric",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway tsxetg3010",
"scope": null,
"trust": 0.3,
"vendor": "schneider electric",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway tsxetg3000",
"scope": null,
"trust": 0.3,
"vendor": "schneider electric",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "etg3000 factorycast hmi gateway",
"version": "1.60.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "tsxetg3000",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "tsxetg3010",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "tsxetg3021",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "tsxetg3022",
"version": null
}
],
"sources": [
{
"db": "IVD",
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00648"
},
{
"db": "BID",
"id": "72254"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007803"
},
{
"db": "NVD",
"id": "CVE-2014-9197"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:etg3000_factorycast_hmi_gateway_firmware:1.60.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:tsxetg3000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:tsxetg3010:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:tsxetg3021:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:tsxetg3022:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2014-9197"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Narendra Shinde of Qualys Security",
"sources": [
{
"db": "BID",
"id": "72254"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
],
"trust": 0.9
},
"cve": "CVE-2014-9197",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.8,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2014-9197",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2015-00648",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-77142",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2014-9197",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2015-00648",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201501-616",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-77142",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00648"
},
{
"db": "VULHUB",
"id": "VHN-77142"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007803"
},
{
"db": "NVD",
"id": "CVE-2014-9197"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request. Supplementary information : CWE Vulnerability type by CWE-284: Improper Access Control ( Inappropriate access control ) Has been identified. Schneider Electric ETG3000 FactoryCast HMI Gateway is a web-based SCADA system. The vulnerability is caused by the program not enforcing adequate access controls when storing the rde.jar file in the web root directory",
"sources": [
{
"db": "NVD",
"id": "CVE-2014-9197"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007803"
},
{
"db": "CNVD",
"id": "CNVD-2015-00648"
},
{
"db": "BID",
"id": "72254"
},
{
"db": "IVD",
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-77142"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2014-9197",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-15-020-02",
"trust": 2.8
},
{
"db": "BID",
"id": "72254",
"trust": 1.6
},
{
"db": "CNNVD",
"id": "CNNVD-201501-616",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2015-00648",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007803",
"trust": 0.8
},
{
"db": "IVD",
"id": "A627B6E2-2351-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-77142",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00648"
},
{
"db": "VULHUB",
"id": "VHN-77142"
},
{
"db": "BID",
"id": "72254"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007803"
},
{
"db": "NVD",
"id": "CVE-2014-9197"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
]
},
"id": "VAR-201501-0402",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00648"
},
{
"db": "VULHUB",
"id": "VHN-77142"
}
],
"trust": 1.7181818
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00648"
}
]
},
"last_update_date": "2023-12-18T12:30:28.004000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "TSX ETG 30xx V1.60 IR04",
"trust": 0.8,
"url": "http://www.schneider-electric.com/download/ww/en/details/681790255-tsxetg30xx-v160-ir4/?showasiframe=true\u0026amp;reference=etg30xxv160-ir04"
},
{
"title": "Schneider Electric ETG3000 FactoryCast HMI Gateway Unauthorized Access Vulnerability Patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/54277"
},
{
"title": "ETG30xx_V1.60.4_UpgradeFw",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=53568"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-00648"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007803"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-284",
"trust": 1.1
},
{
"problemtype": "CWE-Other",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-77142"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007803"
},
{
"db": "NVD",
"id": "CVE-2014-9197"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-020-02"
},
{
"trust": 1.2,
"url": "http://www.securityfocus.com/bid/72254"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-9197"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-9197"
},
{
"trust": 0.3,
"url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-00648"
},
{
"db": "VULHUB",
"id": "VHN-77142"
},
{
"db": "BID",
"id": "72254"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007803"
},
{
"db": "NVD",
"id": "CVE-2014-9197"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00648"
},
{
"db": "VULHUB",
"id": "VHN-77142"
},
{
"db": "BID",
"id": "72254"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007803"
},
{
"db": "NVD",
"id": "CVE-2014-9197"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-01-27T00:00:00",
"db": "IVD",
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d"
},
{
"date": "2015-01-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-00648"
},
{
"date": "2015-01-27T00:00:00",
"db": "VULHUB",
"id": "VHN-77142"
},
{
"date": "2015-01-20T00:00:00",
"db": "BID",
"id": "72254"
},
{
"date": "2015-01-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-007803"
},
{
"date": "2015-01-27T19:59:00.040000",
"db": "NVD",
"id": "CVE-2014-9197"
},
{
"date": "2015-01-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-01-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-00648"
},
{
"date": "2015-01-28T00:00:00",
"db": "VULHUB",
"id": "VHN-77142"
},
{
"date": "2015-01-20T00:00:00",
"db": "BID",
"id": "72254"
},
{
"date": "2015-01-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-007803"
},
{
"date": "2015-01-28T18:52:02.290000",
"db": "NVD",
"id": "CVE-2014-9197"
},
{
"date": "2015-01-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric ETG3000 FactoryCast HMI Gateway Unauthorized Access Vulnerability",
"sources": [
{
"db": "IVD",
"id": "a627b6e2-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00648"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201501-616"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…