var-201612-0420
Vulnerability from variot
A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions. Siemens SIMATIC WinCC and SIMATIC PCS 7 are industrial automation products from Siemens AG, Germany. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC. A security bypass vulnerability exists in versions prior to SIMATIC WinCC 7.2 and in versions prior to SIMATIC PCS 7 8.0 SP1. An attacker could exploit this vulnerability to execute ActiveX components. Attackers can exploit this issue to obtain sensitive information or cause denial-of-service condition
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201612-0420", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "7.1" }, { "model": "simatic pcs 7", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "simatic pcs 7", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "8.0 sp1" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "7.2" }, { "model": "wincc", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "7.2" }, { "model": "simatic pcs sp1", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "7\u003c8.0" }, { "model": "simatic pcs 7", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "8.0" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "7.1" }, { "model": "simatic wincc sp3 upd", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7.08" }, { "model": "simatic wincc sp3", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7.0" }, { "model": "simatic wincc sp2 upd", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7.012" }, { "model": "simatic wincc sp2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7.0" }, { "model": "simatic wincc sp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7.03" }, { "model": "simatic wincc sp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7.02" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7.0" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "6.2" }, { "model": "simatic pcs", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "78.0" }, { "model": "simatic pcs", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "78" }, { "model": "simatic pcs sp4", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "77.1" }, { "model": "simatic pcs", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "77.1" }, { "model": "simatic pcs", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "77" }, { "model": "simatic wincc", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "7.2" }, { "model": "simatic pcs sp1", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "78.0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic pcs 7", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc", "version": "*" } ], "sources": [ { "db": "IVD", "id": "f04157cb-edf5-490c-9e17-39c08ea58fa8" }, { "db": "CNVD", "id": "CNVD-2016-12696" }, { "db": "BID", "id": "94825" }, { "db": "JVNDB", "id": "JVNDB-2016-006500" }, { "db": "NVD", "id": "CVE-2016-9160" }, { "db": "CNNVD", "id": "CNNVD-201612-334" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "7.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "8.0", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2016-9160" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mingzheng Li from Acorn Network Security Lab", "sources": [ { "db": "BID", "id": "94825" }, { "db": "CNNVD", "id": "CNNVD-201612-334" } ], "trust": 0.9 }, "cve": "CVE-2016-9160", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 4.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2016-9160", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2016-12696", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "f04157cb-edf5-490c-9e17-39c08ea58fa8", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-97980", "impactScore": 4.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.2, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.1, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2016-9160", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2016-9160", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2016-12696", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201612-334", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "f04157cb-edf5-490c-9e17-39c08ea58fa8", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-97980", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "f04157cb-edf5-490c-9e17-39c08ea58fa8" }, { "db": "CNVD", "id": "CNVD-2016-12696" }, { "db": "VULHUB", "id": "VHN-97980" }, { "db": "JVNDB", "id": "JVNDB-2016-006500" }, { "db": "NVD", "id": "CVE-2016-9160" }, { "db": "CNNVD", "id": "CNNVD-201612-334" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in SIEMENS SIMATIC WinCC (All versions \u003c SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions \u003c SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions. Siemens SIMATIC WinCC and SIMATIC PCS 7 are industrial automation products from Siemens AG, Germany. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC. A security bypass vulnerability exists in versions prior to SIMATIC WinCC 7.2 and in versions prior to SIMATIC PCS 7 8.0 SP1. An attacker could exploit this vulnerability to execute ActiveX components. \nAttackers can exploit this issue to obtain sensitive information or cause denial-of-service condition", "sources": [ { "db": "NVD", "id": "CVE-2016-9160" }, { "db": "JVNDB", "id": "JVNDB-2016-006500" }, { "db": "CNVD", "id": "CNVD-2016-12696" }, { "db": "BID", "id": "94825" }, { "db": "IVD", "id": "f04157cb-edf5-490c-9e17-39c08ea58fa8" }, { "db": "VULHUB", "id": "VHN-97980" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2016-9160", "trust": 3.6 }, { "db": "BID", "id": "94825", "trust": 2.6 }, { "db": "ICS CERT", "id": "ICSA-16-348-04", "trust": 2.2 }, { "db": "SIEMENS", "id": "SSA-693129", "trust": 2.0 }, { "db": "SECTRACK", "id": "1037435", "trust": 1.1 }, { "db": "CNNVD", "id": "CNNVD-201612-334", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2016-12696", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2016-006500", "trust": 0.8 }, { "db": "IVD", "id": "F04157CB-EDF5-490C-9E17-39C08EA58FA8", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-97980", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "f04157cb-edf5-490c-9e17-39c08ea58fa8" }, { "db": "CNVD", "id": "CNVD-2016-12696" }, { "db": "VULHUB", "id": "VHN-97980" }, { "db": "BID", "id": "94825" }, { "db": "JVNDB", "id": "JVNDB-2016-006500" }, { "db": "NVD", "id": "CVE-2016-9160" }, { "db": "CNNVD", "id": "CNNVD-201612-334" } ] }, "id": "VAR-201612-0420", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "f04157cb-edf5-490c-9e17-39c08ea58fa8" }, { "db": "CNVD", "id": "CNVD-2016-12696" }, { "db": "VULHUB", "id": "VHN-97980" } ], "trust": 1.5198014883333335 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "f04157cb-edf5-490c-9e17-39c08ea58fa8" }, { "db": "CNVD", "id": "CNVD-2016-12696" } ] }, "last_update_date": "2023-12-18T12:29:52.975000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-693129", "trust": 0.8, "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-693129.pdf" }, { "title": "Patch for security bypass bugs in SIMATIC WinCC and SIMATIC PCS 7 ActiveX controls", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/86164" }, { "title": "SIMATIC WinCC and SIMATIC PCS 7 Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=66299" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2016-12696" }, { "db": "JVNDB", "id": "JVNDB-2016-006500" }, { "db": "CNNVD", "id": "CNNVD-201612-334" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-254", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-97980" }, { "db": "JVNDB", "id": "JVNDB-2016-006500" }, { "db": "NVD", "id": "CVE-2016-9160" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "http://www.securityfocus.com/bid/94825" }, { "trust": 2.2, "url": "https://ics-cert.us-cert.gov/advisories/icsa-16-348-04" }, { "trust": 2.0, "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-693129.pdf" }, { "trust": 1.1, "url": "http://www.securitytracker.com/id/1037435" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-9160" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-9160" }, { "trust": 0.3, "url": "http://support.microsoft.com/kb/240797" }, { "trust": 0.3, "url": "http://www.siemens.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2016-12696" }, { "db": "VULHUB", "id": "VHN-97980" }, { "db": "BID", "id": "94825" }, { "db": "JVNDB", "id": "JVNDB-2016-006500" }, { "db": "NVD", "id": "CVE-2016-9160" }, { "db": "CNNVD", "id": "CNNVD-201612-334" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "f04157cb-edf5-490c-9e17-39c08ea58fa8" }, { "db": "CNVD", "id": "CNVD-2016-12696" }, { "db": "VULHUB", "id": "VHN-97980" }, { "db": "BID", "id": "94825" }, { "db": "JVNDB", "id": "JVNDB-2016-006500" }, { "db": "NVD", "id": "CVE-2016-9160" }, { "db": "CNNVD", "id": "CNNVD-201612-334" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-12-21T00:00:00", "db": "IVD", "id": "f04157cb-edf5-490c-9e17-39c08ea58fa8" }, { "date": "2016-12-21T00:00:00", "db": "CNVD", "id": "CNVD-2016-12696" }, { "date": "2016-12-17T00:00:00", "db": "VULHUB", "id": "VHN-97980" }, { "date": "2016-12-09T00:00:00", "db": "BID", "id": "94825" }, { "date": "2017-01-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-006500" }, { "date": "2016-12-17T03:59:00.263000", "db": "NVD", "id": "CVE-2016-9160" }, { "date": "2016-12-13T00:00:00", "db": "CNNVD", "id": "CNNVD-201612-334" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-12-21T00:00:00", "db": "CNVD", "id": "CNVD-2016-12696" }, { "date": "2017-07-27T00:00:00", "db": "VULHUB", "id": "VHN-97980" }, { "date": "2016-12-20T01:09:00", "db": "BID", "id": "94825" }, { "date": "2017-01-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-006500" }, { "date": "2017-07-27T01:29:06.773000", "db": "NVD", "id": "CVE-2016-9160" }, { "date": "2016-12-19T00:00:00", "db": "CNNVD", "id": "CNNVD-201612-334" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201612-334" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "SIEMENS SIMATIC WinCC and SIEMENS SIMATIC PCS 7 In ActiveX Vulnerability that can crash components", "sources": [ { "db": "JVNDB", "id": "JVNDB-2016-006500" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "lack of information", "sources": [ { "db": "CNNVD", "id": "CNNVD-201612-334" } ], "trust": 0.6 } }
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.