VAR-201702-0850
Vulnerability from variot - Updated: 2023-12-18 14:05An issue was discovered in Emerson SE4801T0X Redundant Wireless I/O Card V13.3, and SE4801T1X Simplex Wireless I/O Card V13.3. DeltaV Wireless I/O Cards (WIOC) running the firmware available in the DeltaV system, release v13.3, have the SSH (Secure Shell) functionality enabled unnecessarily. EmersonSE4801T0XRedundantWirelessI/OCard and SE4801T1XSimplexWirelessI/OCard are wireless I/O cards from Emerson Electric, Inc., which are used to connect workstations and servers in DeltaV (software for process control) networks. A security vulnerability exists in EmersonSE4801T0XRedundantWirelessI/OCardV13.3 and SE4801T1XSimplexWirelessI/OCardV13.3. A remote attacker could exploit the vulnerability to access the device's file system by using an open port. Multiple Emerson products are prone to a security-bypass vulnerability. An attacker may exploit this issue to bypass certain security restrictions and perform unauthorized actions. This may lead to further attacks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201702-0850",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "se4801t1x simplex wireless i/o card",
"scope": "eq",
"trust": 1.7,
"vendor": "emerson",
"version": "13.3"
},
{
"model": "se4801t0x redundant wireless i/o card",
"scope": "eq",
"trust": 1.7,
"vendor": "emerson",
"version": "13.3"
},
{
"model": "se4801t1x simplex wireless i\\/o card",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "13.3"
},
{
"model": "se4801t0x redundant wireless i\\/o card",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "13.3"
},
{
"model": "se4801t0x redundant wireless i/o card",
"scope": null,
"trust": 0.8,
"vendor": "emerson",
"version": null
},
{
"model": "se4801t1x simplex wireless i/o card",
"scope": null,
"trust": 0.8,
"vendor": "emerson",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "se4801t0x redundant i o card",
"version": "13.3"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "se4801t1x simplex i o card",
"version": "13.3"
}
],
"sources": [
{
"db": "IVD",
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b"
},
{
"db": "CNVD",
"id": "CNVD-2016-11896"
},
{
"db": "BID",
"id": "94586"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-007965"
},
{
"db": "NVD",
"id": "CVE-2016-9347"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-705"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:emerson:se4801t0x_redundant_wireless_i\\/o_card_firmware:13.3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:emerson:se4801t0x_redundant_wireless_i\\/o_card:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:emerson:se4801t1x_simplex_wireless_i\\/o_card_firmware:13.3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:emerson:se4801t1x_simplex_wireless_i\\/o_card:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2016-9347"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The vendor reported this issue.",
"sources": [
{
"db": "BID",
"id": "94586"
}
],
"trust": 0.3
},
"cve": "CVE-2016-9347",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.5,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:A/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Adjacent Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.4,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2016-9347",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:A/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.2,
"id": "CNVD-2016-11896",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:H/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.2,
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:A/AC:H/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 5.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.5,
"id": "VHN-98167",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:A/AC:M/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"author": "NVD",
"availabilityImpact": "LOW",
"baseScore": 5.0,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.6,
"impactScore": 3.4,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
},
{
"attackComplexity": "High",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "Low",
"baseScore": 5.0,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2016-9347",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2016-9347",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2016-11896",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201611-705",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-98167",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b"
},
{
"db": "CNVD",
"id": "CNVD-2016-11896"
},
{
"db": "VULHUB",
"id": "VHN-98167"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-007965"
},
{
"db": "NVD",
"id": "CVE-2016-9347"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-705"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered in Emerson SE4801T0X Redundant Wireless I/O Card V13.3, and SE4801T1X Simplex Wireless I/O Card V13.3. DeltaV Wireless I/O Cards (WIOC) running the firmware available in the DeltaV system, release v13.3, have the SSH (Secure Shell) functionality enabled unnecessarily. EmersonSE4801T0XRedundantWirelessI/OCard and SE4801T1XSimplexWirelessI/OCard are wireless I/O cards from Emerson Electric, Inc., which are used to connect workstations and servers in DeltaV (software for process control) networks. A security vulnerability exists in EmersonSE4801T0XRedundantWirelessI/OCardV13.3 and SE4801T1XSimplexWirelessI/OCardV13.3. A remote attacker could exploit the vulnerability to access the device\u0027s file system by using an open port. Multiple Emerson products are prone to a security-bypass vulnerability. \nAn attacker may exploit this issue to bypass certain security restrictions and perform unauthorized actions. This may lead to further attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2016-9347"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-007965"
},
{
"db": "CNVD",
"id": "CNVD-2016-11896"
},
{
"db": "BID",
"id": "94586"
},
{
"db": "IVD",
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b"
},
{
"db": "VULHUB",
"id": "VHN-98167"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2016-9347",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-16-334-03",
"trust": 3.4
},
{
"db": "BID",
"id": "94586",
"trust": 2.6
},
{
"db": "CNNVD",
"id": "CNNVD-201611-705",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2016-11896",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2016-007965",
"trust": 0.8
},
{
"db": "IVD",
"id": "A3B16A9F-D6C5-455D-B34F-EA13CB0F0B9B",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-98167",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b"
},
{
"db": "CNVD",
"id": "CNVD-2016-11896"
},
{
"db": "VULHUB",
"id": "VHN-98167"
},
{
"db": "BID",
"id": "94586"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-007965"
},
{
"db": "NVD",
"id": "CVE-2016-9347"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-705"
}
]
},
"id": "VAR-201702-0850",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b"
},
{
"db": "CNVD",
"id": "CNVD-2016-11896"
},
{
"db": "VULHUB",
"id": "VHN-98167"
}
],
"trust": 1.5666666999999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b"
},
{
"db": "CNVD",
"id": "CNVD-2016-11896"
}
]
},
"last_update_date": "2023-12-18T14:05:51.071000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "\u5206\u6563\u578b\u5236\u5fa1\u30b7\u30b9\u30c6\u30e0\uff08DCS\uff09 DeltaV\u30b7\u30b9\u30c6\u30e0",
"trust": 0.8,
"url": "http://www.emerson.co.jp/div/epm/product5_1.html"
},
{
"title": "Patches for multiple Emerson product security bypass vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/85021"
},
{
"title": "Emerson SE4801T0X Redundant Wireless I/O Card and SE4801T1X Simplex Wireless I/O Card Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65972"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2016-11896"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-007965"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-705"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-254",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-98167"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-007965"
},
{
"db": "NVD",
"id": "CVE-2016-9347"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.4,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-16-334-03"
},
{
"trust": 2.3,
"url": "http://www.securityfocus.com/bid/94586"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-9347"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-9347"
},
{
"trust": 0.3,
"url": "http://www2.emersonprocess.com/en-us/brands/edservices/automationsystems/deltav/pages/deltavtraining.aspx"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2016-11896"
},
{
"db": "VULHUB",
"id": "VHN-98167"
},
{
"db": "BID",
"id": "94586"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-007965"
},
{
"db": "NVD",
"id": "CVE-2016-9347"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-705"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b"
},
{
"db": "CNVD",
"id": "CNVD-2016-11896"
},
{
"db": "VULHUB",
"id": "VHN-98167"
},
{
"db": "BID",
"id": "94586"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-007965"
},
{
"db": "NVD",
"id": "CVE-2016-9347"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-705"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-12-06T00:00:00",
"db": "IVD",
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b"
},
{
"date": "2016-12-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2016-11896"
},
{
"date": "2017-02-13T00:00:00",
"db": "VULHUB",
"id": "VHN-98167"
},
{
"date": "2016-11-29T00:00:00",
"db": "BID",
"id": "94586"
},
{
"date": "2017-04-03T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-007965"
},
{
"date": "2017-02-13T21:59:01.830000",
"db": "NVD",
"id": "CVE-2016-9347"
},
{
"date": "2016-11-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-705"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-12-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2016-11896"
},
{
"date": "2017-03-13T00:00:00",
"db": "VULHUB",
"id": "VHN-98167"
},
{
"date": "2016-12-20T00:04:00",
"db": "BID",
"id": "94586"
},
{
"date": "2017-04-03T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-007965"
},
{
"date": "2017-03-13T16:52:21.450000",
"db": "NVD",
"id": "CVE-2016-9347"
},
{
"date": "2016-12-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-705"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "specific network environment",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201611-705"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Emerson SE4801T0X Redundant and SE4801T1X Simplex Wireless I/O Card In the firmware SSH Vulnerabilities whose features are unnecessarily enabled",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-007965"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "IVD",
"id": "a3b16a9f-d6c5-455d-b34f-ea13cb0f0b9b"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-705"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.