var-201709-0973
Vulnerability from variot

Directory traversal vulnerability in synphotoio in Synology Photo Station before 6.7.4-3433 and 6.3-2968 allows remote authenticated users to read arbitrary files via unspecified vectors. Synology Photo Station Contains a path traversal vulnerability.Information may be obtained. Synology Photo Station is a set of solutions from Synology for sharing pictures, videos and blogs on the Internet

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201709-0973",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "photo station",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "synology",
        "version": "6.3-2967"
      },
      {
        "model": "photo station",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "synology",
        "version": "6.7.3-3432"
      },
      {
        "model": "photo station",
        "scope": null,
        "trust": 0.8,
        "vendor": "synology",
        "version": null
      },
      {
        "model": "photo station",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "synology",
        "version": "6.3-2967"
      },
      {
        "model": "photo station",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "synology",
        "version": "6.7.3-3432"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11162"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:synology:photo_station:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "6.3-2967",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:synology:photo_station:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "6.7.3-3432",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-11162"
      }
    ]
  },
  "cve": "CVE-2017-11162",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.0,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2017-11162",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "VHN-101557",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2017-11162",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2017-11162",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201707-371",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-101557",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-101557"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11162"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Directory traversal vulnerability in synphotoio in Synology Photo Station before 6.7.4-3433 and 6.3-2968 allows remote authenticated users to read arbitrary files via unspecified vectors. Synology Photo Station Contains a path traversal vulnerability.Information may be obtained. Synology Photo Station is a set of solutions from Synology for sharing pictures, videos and blogs on the Internet",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-11162"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "db": "VULHUB",
        "id": "VHN-101557"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-11162",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-007658",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-371",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-101557",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-101557"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11162"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ]
  },
  "id": "VAR-201709-0973",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-101557"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2023-12-18T12:29:24.484000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Synology-SA-17:35 Photo Station",
        "trust": 0.8,
        "url": "https://www.synology.com/en-global/support/security/synology_sa_17_35_photostation"
      },
      {
        "title": "Synology Photo Station Repair measures for path traversal vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=99904"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-22",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-101557"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11162"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://www.synology.com/en-global/support/security/synology_sa_17_35_photostation"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-11162"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11162"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-101557"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11162"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-101557"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11162"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-09-08T00:00:00",
        "db": "VULHUB",
        "id": "VHN-101557"
      },
      {
        "date": "2017-09-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "date": "2017-09-08T14:29:00.260000",
        "db": "NVD",
        "id": "CVE-2017-11162"
      },
      {
        "date": "2017-07-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-101557"
      },
      {
        "date": "2017-09-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "date": "2019-10-09T23:21:59.337000",
        "db": "NVD",
        "id": "CVE-2017-11162"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Synology Photo Station Path traversal vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-007658"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ],
    "trust": 1.4
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "path traversal",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-371"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.