VAR-201802-0485

Vulnerability from variot - Updated: 2023-12-18 12:19

A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module. A buffer-overflow vulnerability 2. A denial-of-service vulnerability 3. An access-bypass vulnerability 4. Multiple security-bypass vulnerabilities Attackers can exploit these issues to execute arbitrary code within the context of affected device, cause a denial-of-service condition, bypass certain security restrictions, or gain unauthorized access to the device and perform unauthorized actions. This may lead to complete compromise of the device

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201802-0485",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "medfusion 4000 wireless syringe infusion pump",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "smiths medical",
        "version": "1.1"
      },
      {
        "model": "medfusion 4000 wireless syringe infusion pump",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "smiths medical",
        "version": "1.5"
      },
      {
        "model": "medfusion 4000 wireless syringe infusion pump",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "smiths medical",
        "version": "1.6"
      },
      {
        "model": "medical medfusion wireless syringe infusion pump",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "smiths",
        "version": "40001.1"
      },
      {
        "model": "medical medfusion wireless syringe infusion pump",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "smiths",
        "version": "40001.5"
      },
      {
        "model": "medical medfusion wireless syringe infusion pump",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "smiths",
        "version": "40001.6"
      },
      {
        "model": "medfusion wireless syringe infusion pump",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "smiths medical",
        "version": "40001.6"
      },
      {
        "model": "medfusion wireless syringe infusion pump",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "smiths medical",
        "version": "40001.5"
      },
      {
        "model": "medfusion wireless syringe infusion pump",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "smiths medical",
        "version": "40001.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "medfusion 4000 syringe infusion pump",
        "version": "1.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "medfusion 4000 syringe infusion pump",
        "version": "1.5"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "medfusion 4000 syringe infusion pump",
        "version": "1.6"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6be18953-f138-42a5-88a9-7f86890cf0d8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      },
      {
        "db": "BID",
        "id": "100665"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12726"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201709-524"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.1:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.6:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.5:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-12726"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Scott Gayou",
    "sources": [
      {
        "db": "BID",
        "id": "100665"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201709-524"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2017-12726",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2017-12726",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 4.9,
            "id": "CNVD-2017-25718",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 4.9,
            "id": "6be18953-f138-42a5-88a9-7f86890cf0d8",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-103277",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "LOW",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "Low",
            "baseScore": 7.3,
            "baseSeverity": "High",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2017-12726",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2017-12726",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-25718",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201709-524",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "6be18953-f138-42a5-88a9-7f86890cf0d8",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-103277",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6be18953-f138-42a5-88a9-7f86890cf0d8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103277"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12726"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201709-524"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module. A buffer-overflow vulnerability\n2. A denial-of-service vulnerability\n3. An access-bypass vulnerability\n4. Multiple security-bypass vulnerabilities\nAttackers can exploit these issues to execute arbitrary code within the context of affected device, cause a denial-of-service condition, bypass certain security restrictions, or gain unauthorized access to the device and perform unauthorized actions. This may lead to complete compromise of the device",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-12726"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      },
      {
        "db": "BID",
        "id": "100665"
      },
      {
        "db": "IVD",
        "id": "6be18953-f138-42a5-88a9-7f86890cf0d8"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103277"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-12726",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSMA-17-250-02A",
        "trust": 2.5
      },
      {
        "db": "BID",
        "id": "100665",
        "trust": 2.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201709-524",
        "trust": 0.9
      },
      {
        "db": "ICS CERT",
        "id": "ICSMA-17-250-02",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-25718",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012530",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "6BE18953-F138-42A5-88A9-7F86890CF0D8",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-103277",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6be18953-f138-42a5-88a9-7f86890cf0d8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103277"
      },
      {
        "db": "BID",
        "id": "100665"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12726"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201709-524"
      }
    ]
  },
  "id": "VAR-201802-0485",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "6be18953-f138-42a5-88a9-7f86890cf0d8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103277"
      }
    ],
    "trust": 1.9
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6be18953-f138-42a5-88a9-7f86890cf0d8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:19:07.378000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Medfusion 4000 Wireless Syringe Infusion Pump",
        "trust": 0.8,
        "url": "https://www.smiths-medical.com/products/infusion/syringe-infusion/syringe-infusion-pumps/medfusion-4000-wireless-syringe-infusion-pump"
      },
      {
        "title": "Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Patch for Hard Coded Password Vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/101782"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-798",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-103277"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12726"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://ics-cert.us-cert.gov/advisories/icsma-17-250-02a"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/100665"
      },
      {
        "trust": 0.9,
        "url": "https://ics-cert.us-cert.gov/advisories/icsma-17-250-02"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-12726"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-12726"
      },
      {
        "trust": 0.3,
        "url": "https://www.smiths-medical.com/products/infusion/syringe-infusion/syringe-infusion-pumps/medfusion-4000-wireless-syringe-infusion-pump"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103277"
      },
      {
        "db": "BID",
        "id": "100665"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12726"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201709-524"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "6be18953-f138-42a5-88a9-7f86890cf0d8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103277"
      },
      {
        "db": "BID",
        "id": "100665"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12726"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201709-524"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-09-08T00:00:00",
        "db": "IVD",
        "id": "6be18953-f138-42a5-88a9-7f86890cf0d8"
      },
      {
        "date": "2017-09-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      },
      {
        "date": "2018-02-15T00:00:00",
        "db": "VULHUB",
        "id": "VHN-103277"
      },
      {
        "date": "2017-09-07T00:00:00",
        "db": "BID",
        "id": "100665"
      },
      {
        "date": "2018-03-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      },
      {
        "date": "2018-02-15T10:29:00.570000",
        "db": "NVD",
        "id": "CVE-2017-12726"
      },
      {
        "date": "2017-09-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201709-524"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-09-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-25718"
      },
      {
        "date": "2018-03-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-103277"
      },
      {
        "date": "2017-09-07T00:00:00",
        "db": "BID",
        "id": "100665"
      },
      {
        "date": "2018-03-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      },
      {
        "date": "2018-03-02T14:39:57.763000",
        "db": "NVD",
        "id": "CVE-2017-12726"
      },
      {
        "date": "2017-09-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201709-524"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201709-524"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities related to the use of hard-coded credentials",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012530"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "lack of information",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201709-524"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…